Search results

Jump to navigation Jump to search
  • Get Tag List (category Models) (section Get Tag List Format)
    easiest way to create the Get Tag List is by using MS Excel. The Get Tag List format and example is given above. Once the Get Tag List is created, save it as
    6 KB (605 words) - 16:38, 2 August 2023
  • Set Tag List (category Models) (section Set Tag List Format)
    The Get Tag List model also supports optional multiple columns so if the current column number for this is changed at the same time, the Get Tag List
    9 KB (817 words) - 19:09, 2 August 2023
  • ; 1) [[Set Tag List]] Model is used to Set the user defined data ; 2) [[Get Tag List]] Model is used to report the required value (with GetAtEnd option
    19 KB (907 words) - 02:09, 21 February 2024
  • lines within their set tag list by starting the line with a semi-colon (;), similar to PGMs. This also applies to Get Tag List Model. The Environmental Heat
    42 KB (6,030 words) - 18:10, 2 August 2023
  • version released in January 2009. Implemented new Get Tag List Model. New Alumina 3 Bayer Species Model. (Note that if you were using earlier Build 126 versions
    18 KB (2,754 words) - 03:55, 11 September 2023
  • Orderby [Graphic] [Parent.Tag] [Index], Groupby [Parent.Tag] [Tag] BoldHeading:1, Clear: On) To create a list for all the PIDs: SysCAD_TagSelect(PID, V,50,1000
    29 KB (2,682 words) - 14:42, 3 April 2024
  • Model Procedures (category Sub-Models)
    use the "Copy Tag for PGM" option to Copy the Tag from Access Window Right click popup list Use Copy Tag (without the model name) when a tag is being concatenated
    20 KB (1,014 words) - 01:44, 6 September 2023
  • when mouse hovers over the drop list field includes 'Underlying tag is a String type' in the description. When making the droplist selection from a PGM
    34 KB (1,045 words) - 23:50, 5 September 2023
  • General Controller (category Models) (section Model Theory)
    and PGMs Set Tag Controller - the user may carry out the simple ratio control and set multiple tags using the the Set Tag Controller model. The diagram
    20 KB (1,211 words) - 03:31, 5 April 2024
  • Variable Tag: some report type (e.g.: Tag List report) requires the Full Variable Tag, please use Copy Full Tag to copy the tag. Primary tag: When a full
    24 KB (2,037 words) - 17:02, 2 August 2023
  • a simple list of all models. Flange Flows is a list of all flanges (the connection flange objects between pipes and models). Tears is a list of all Solver
    23 KB (1,074 words) - 14:19, 2 August 2023
  • and choose the Copy Graphics, Tag List to Clipboard option, then paste them into MS Excel. To obtain an equipment list for a selected graphics page, from
    11 KB (986 words) - 03:35, 5 April 2024
  • stricter model tag naming rules by not allowing four more symbols in tag names (\ ' " and ;). Give error message at project load if any models contain illegal
    33 KB (5,180 words) - 11:24, 14 February 2024
  • Build139 or later, user can get the used/unused species list directly from Plant Model - Species tab. How to generate a list of Species with Flow, useful
    7 KB (589 words) - 03:35, 7 February 2023
  • Models (category Models) (section General Models)
    implemented as a Species Properties Model but as a unit model for use at appropriate locations in a plant model. These models use OLI Systems leading Electrolyte
    62 KB (2,065 words) - 03:33, 23 April 2024
  • Exec(Criteria_Tag, false, false) ; find total number of SpeciesChanges SpciesChangeCount = SpeciesChanges.GetLen() ; get all species change flows flow_tag = Concatenate("
    7 KB (632 words) - 06:27, 22 February 2024
  • Vapour Liquid Equilibrium (VLE) (category Sub-Models) (section Model Theory)
    vapour and liquid species in the model or stream. The VLE sub-model is used in a number of unit models. Different models may have options to specify some
    22 KB (1,593 words) - 00:17, 13 December 2023
  • Feeder-Cross Page Connector (category Models) (section Model Theory)
    first section, Model. Model determines which species model the feeder uses. The options available to the user will depend on the species model used by the
    47 KB (2,683 words) - 09:04, 2 February 2024
  • allows the user to set some solver related tags as well as display the current status for the SysCAD application. Tag groups on this tab include: Project Solver
    21 KB (106 words) - 10:13, 3 August 2023
  • Data dialog box will bring up the following pop up list: For most of the options on the pop up list, they are simply an alternate method to access the
    15 KB (1,320 words) - 11:47, 3 May 2024
  • Analysis - scenarios, tag list document, command script and COM automation. Topics covered in this document include: Using sub models in the unit operation
    8 KB (922 words) - 01:42, 10 May 2024
  • variable, user may get "Unknown tag "GM.IOs.[P_002].Splt.H2O(l) (%)'", this is because the [] function expects a full tag instead of partial tag. Please see troubleshooting
    11 KB (1,465 words) - 00:49, 19 January 2023
  • Marshal IO tag list must be made directly in the tag list file, there is no user interface in SysCAD or SysCAD Marshal to manage the tag list. When adjustment
    33 KB (5,359 words) - 10:13, 1 February 2024
  • SysCAD_SetTagList(ReportName, Tag Location (either H or V), Search Length). These parameters are explained in Basic Format of a simple Get Tag Report. Some
    11 KB (1,168 words) - 18:42, 2 August 2023
  • of a changed tag. This is relevant to the Get Tag List, Set Tag List, Plant Model Set Tag List, Events, Profile and Queue Profile models, as well as the
    3 KB (9 words) - 10:53, 27 April 2021
  • Profile (category Models) (section Adding this Model to a Project)
    Navigation: Models ➔ Control 2 Models ➔ Profile Controller The Profiler model is only used in Dynamic projects. It allows users to vary input parameters
    17 KB (1,330 words) - 05:32, 5 September 2023
  • mathematical model is attached to some selected graphics from the DXF drawing. The unit model's mathematical model and its graphics are linked by a tag name:
    13 KB (1,068 words) - 14:18, 2 August 2023
  • Controller or Model Procedures; Tags may also be set from any of the following units: Set Tag List Model, Profile Model, Events Model, Queue Model, Noise Model
    7 KB (855 words) - 02:06, 15 June 2021
  • right click on the tag and select "Open Find Results" menu option (or press F8) to get a list of values for this tag in all unit models of the same type
    114 KB (16,094 words) - 02:05, 24 April 2024
  • PGM Include Files, Get Tag List, Set Tag List, Plant Model Set Tag List, Task Model, Events Model, Profile Model, Queue Profile Model, Command Scripts A
    3 KB (342 words) - 23:57, 24 March 2021
  • Tag List Step 3: Create 2 csv files, one containing the User Defined values for the Set Tag List and another containing the results for the Get Tag List.
    19 KB (2,641 words) - 03:13, 7 February 2024
  • Au(s) (oz/d)" print ("Gold in product", end=" ") print (Tags.TagValue(goldFlow)) ## Get a tag value Solver = Prj.Solver ProBal = Solver.ProBal ProBal.Start()
    11 KB (1,558 words) - 18:42, 2 August 2023
  • Class (section ClassList)
    class name to the unit model tag through use of UnitTag = ClassTag() within the class definition, then we can use the unit tag name as the class instance
    46 KB (4,504 words) - 01:29, 12 March 2024
  • you can use any of those that you see in the list when you insert a unit model, or just "*Default*" to get the default symbol. The final parameters are
    6 KB (869 words) - 18:56, 1 September 2022
  • Noise Controller (category Models) (section Model Theory)
    }[/math] = Standard Deviation For all methods, the tag PlantModel.RandomSeedAtStart (set on the Plant Model - FlwSolve page) affects the repeatability of the
    13 KB (416 words) - 13:50, 1 February 2024
  • the SysCAD Excel Get Tag Reports, the tag "Graphic" may be used to report the name of the graphics window that the unit is on. See List Graphics Symbols
    16 KB (2,028 words) - 03:06, 5 April 2024
  • Queue Profile (category Models) (section Adding this Model to a Project)
    SysCAD finds a blank column or an invalid tag, all remaining tags are ignored. Queue Profiles do not support string tags. The columns in the profile should contain
    7 KB (340 words) - 01:37, 6 September 2023
  • stage. If the Set Tag List or General Controller appear to be setting tags too late, then consider using the Set Tag List in the Plant Model - Project or methods
    4 KB (570 words) - 03:41, 27 March 2024
  • Configuration File Sort either by DLL or Group: See Model Selection for more information on adding models to the configuration file. Insert into Project Flowsheet
    18 KB (1,286 words) - 09:26, 2 February 2024
  • Makeup Source (category Models) (section Model)
    first section, Model. Model determines which species model the feeder uses. The options available to the user will depend on the species model used by the
    21 KB (899 words) - 03:34, 5 April 2024
  • example 2 on how to set up user calculations. The model is not currently sensitive to pH or temperature. The model assumes that the pH and temperature are correct
    47 KB (3,928 words) - 05:12, 21 February 2024
  • PID Controller (category Models) (section Model Theory)
    iteration is treated as a "one second time increment". The PID Output tag and the Measured tag, will have coloured triangles shown in the access window of those
    34 KB (2,509 words) - 03:27, 5 April 2024
  • Reactor (Gibbs FEM) (category Models) (section Model Theory)
    FEM model is used in an overall plant model, the user has no direct control over which species are present in the feed, and consequently the model may
    73 KB (3,653 words) - 05:20, 7 February 2024
  • Events (category Models) (section Adding this Model to a Project)
    sets SysCAD tags at regular intervals using a profile that is read in from a CSV file. The Scheduled Events model will set a single SysCAD tag to a required
    10 KB (481 words) - 13:51, 1 February 2024
  • Navigation: Models ➔ Control 2 Models ➔ Scheduled Events This model is used in Dynamic Simulation only. This unit is similar to the Downtime model and the
    11 KB (379 words) - 01:44, 6 September 2023
  • inlet stream has a quality model, all the outlet streams will have the same quality models. Unless in some cases where a unit model can be configured to prevent
    10 KB (1,566 words) - 01:36, 6 September 2023
  • species model in the configuration file as shown below. It is then possible to select the Bayer model (either Bayer3 or a client-specific Bayer model). On
    28 KB (784 words) - 14:07, 14 March 2024
  • contain a number of documents, these may include: Model files - ModelData.db3, stores the project model data. Graphics files - xxxx.DXF and xxxx.scg file
    13 KB (1,190 words) - 03:38, 5 April 2024
  • Signal Waveform (category Models) (section Model Theory)
    Navigation: Models ➔ Control 2 Models ➔ Signal Waveform Controller The Signal Waveform Controller model is used in Dynamic projects. It allows input of
    19 KB (1,298 words) - 05:23, 7 February 2024
  • imbalance in the model, user will be given a warning, to prevent this, make sure the steam supply is auto adjusted via General controller / Set Tag Controller
    49 KB (3,135 words) - 01:11, 7 February 2024
  • for configuring the model is: Make sure the project contains at least one of the PHREEQC Model Configuration model, and the model is loaded with the correct
    11 KB (2,072 words) - 04:02, 28 March 2024
  • incorporated into the SysCAD model using a General Controller. The unit cost would be an input parameter to the model and the model would use the calculated
    20 KB (2,743 words) - 03:41, 27 March 2024
  • Slew Rate Controller (category Models) (section Model Theory)
    Configuration File Sort either by DLL or Group: See Model Selection for more information on adding models to the configuration file. Insert into Project Flowsheet
    15 KB (723 words) - 13:52, 1 February 2024
  • Simple Condenser (category Models) (section Behaviour when Model is OFF)
    Condensed or Mass Condensed Tag - The maximum amount (mass flow) to be condensed is specified by the user or set equal to a tag. Fraction Condensed - The
    23 KB (1,291 words) - 05:07, 7 February 2024
  • within the model. If the Select statement includes [SubType] then the TagSelect Engine returns full SubType model tags (including dots in the tag) rather
    2 KB (324 words) - 12:06, 20 February 2024
  • from the model. The Falling Film Evaporation Project, which is distributed with SysCAD in the Examples folder, demonstrates the use of this model in a SysCAD
    33 KB (2,346 words) - 09:40, 20 February 2024
  • SetAt(2, Tag3) TagGroup.SetAt(4, "P_7.To (C)") Required_Tag= TagGroup.GetAt(1) See also Example PGM to create a Unit Tag List
    9 KB (474 words) - 08:54, 10 May 2024
  • historical tag values but will retain the list of tags that are recorded in the data historian. Delete button: This will delete all the historical tag values
    12 KB (1,370 words) - 19:05, 2 August 2023
  • Environmental Heat Exchanger (EHX) (category Sub-Models) (section Model Theory)
    equation given above. This section contains a list of Error Messages that you may get when using the EHX sub-model. It includes reasons why you may see these
    36 KB (1,127 words) - 03:33, 5 April 2024
  • workflow for configuring the model is: Make sure the project contains at least one of the AQSol Model Configuration model, and the model is loaded with the correct
    11 KB (2,040 words) - 08:18, 14 March 2024
  • Flotation Cell (category Models) (section Behaviour when Model is OFF)
    is connected but there is no vent stream, then the user will get a warning but the model will still function. If there is no vent stream, all vapours will
    19 KB (1,611 words) - 05:14, 7 February 2024
  • reverse order. Change Tag now includes changing of tags referenced in PID functions and in data fields for General Controllers marked as {tag} variables. Reroute
    6 KB (696 words) - 17:40, 2 August 2023
  • the input list. The report used to get a list values from SysCAD to Excel is: SysCAD_TagList Report Type This is shown in Columns D('SysCAD Tags) & E(Results
    3 KB (460 words) - 03:12, 15 June 2021
  • Crusher2 (category Models) (section Model Theory)
    Partition Curves Whiten Crusher Model Selection/Breakage Models Test Data The specific model is selected with the Method drop down list on the Crusher2 or Crusher
    35 KB (768 words) - 09:38, 2 February 2024
  • Downtime (category Models) (section Model Theory)
    and reset based on rules for each of the Downtime events. The model can then set a single tag to an Active or Inactive value, depending on whether the unit
    25 KB (626 words) - 01:43, 6 September 2023
  • Evaporator (category Models) (section Behaviour when Model is OFF)
    Configuration File Sort either by DLL or Group: See Model Selection for more information on adding models to the configuration file. Insert into Project Flowsheet
    7 KB (1,469 words) - 03:58, 24 April 2024
  • workflow for configuring the model is: Make sure the project contains at least one of the OLI Model Configuration model, and the model is loaded with the correct
    11 KB (2,080 words) - 08:25, 14 March 2024
  • NOTE: This model is being phased out and will be removed in future versions (refer to Discontinued Models and Dlls). In Build 139, to add this model to the
    22 KB (1,914 words) - 09:40, 2 February 2024
  • Engine only returned a list of model tags that meet a specified criteria. It is now possible to get a list of all SubModels or SubTypes that meet a specified
    8 KB (1,113 words) - 11:50, 20 February 2024
  • stags, running the model, then getting the values from tags in the list gtags. We are using a wrapper around COM, implemented in the module SysCAD.syscadif
    13 KB (1,431 words) - 02:29, 3 October 2023
  • mode. Industry related models - e.g. General Alumina models. The General Alumina model contains a generic Bayer Liquor Properties model for use when simulating
    9 KB (1,571 words) - 01:42, 15 June 2021
  • project save names, most of the SysCAD model tag naming rules also apply to these. Please see Model Tags for list of the illegal characters. If any existing
    642 bytes (778 words) - 11:43, 25 May 2021
  • Sugar properties model from the list as show below: In Step 2 of edit configuration file, make sure all the required compounds (under the Model Theory section)
    27 KB (1,424 words) - 13:59, 27 March 2024
  • Navigation: Models ➔ Sub-Models ➔ Embedded Heat Exchanger (HX) Related Links: Evaporator, Potash Evaporator The Embedded Heat Exchanger is used in the
    1 KB (502 words) - 23:58, 15 January 2023
  • April 2024 - SysCAD 9.3 Build 139.35250 Related Links: General Controller, Model Procedures, Example PGM Files, Frequently Asked Questions, Notepad++ Auto-complete
    12 KB (34 words) - 12:11, 20 February 2024
  • contain a number of documents, these may include: Model files - ModelData.db3, stores the project model data. Graphics files - xxxx.DXF and xxxx.scg file
    14 KB (2,360 words) - 03:06, 5 April 2024
  • Potash Evaporator (category Models) (section Behaviour when Model is OFF)
    exchangers. This model allows the user to embed these heat exchangers as part of the model. (This is often more efficient when carrying out the modelling calculations
    33 KB (1,430 words) - 06:10, 24 April 2024
  • (kg/h),292 CSTR.TankVolume,300 Text file Get Tag List Report Template Example: ReportListCriteria.csv (partial) Tag ;Plant Feed Characteristics ;Ore Slurry
    10 KB (1,420 words) - 06:53, 19 February 2024
  • PHREEQC Evaporator (category Models) (section Behaviour when Model is OFF)
    for configuring the model is: Make sure the project contains at least one of the PHREEQC Model Configuration model, and the model is loaded with the correct
    9 KB (2,350 words) - 04:05, 28 March 2024
  • AQSol Evaporator (category Models) (section Behaviour when Model is OFF)
    workflow for configuring the model is: Make sure the project contains at least one of the AQSol Model Configuration model, and the model is loaded with the correct
    9 KB (2,284 words) - 02:45, 14 March 2024
  • OLI Evaporator (category Models) (section Behaviour when Model is OFF)
    workflow for configuring the model is: Make sure the project contains at least one of the OLI Model Configuration model, and the model is loaded with the correct
    9 KB (2,327 words) - 02:49, 14 March 2024
  • Projects ➔ SysCAD 9.3 Tag Changes Related Links: Build 136 Release Notes, SysCAD Tags Changes affecting various types of tags and tag management new to SysCAD
    291 bytes (34 words) - 12:08, 17 May 2023
  • information. The key representation of the model is the Graphics Window which is typically used to construct a model in a project. Other windows are used to
    3 KB (452 words) - 14:52, 1 June 2023
  • = syscadif.SysCADCom() After a project is loaded, you can get and set tags, and run the model or scenarios. For convenience, operators __getitem__ and __setitem__
    5 KB (234 words) - 12:08, 20 February 2024
  • "Main" Tab. Set Tag List Report - Used to set a list of user specified values from Excel to SysCAD. Please See "Criteria" Tab, Column G. Tag List Report - Used
    6 KB (767 words) - 03:11, 15 June 2021
  • function to retrieve a list of model tags meeting a SQL type select query, similar to the Excel Tag Select Reports. A list of all SubType tags, for example reaction
    6 KB (462 words) - 02:45, 5 February 2024
  • for folder/file paths. The RefTag list is for user information only, it builds and displays a list of all the reference tags used in the projects. These
    7 KB (393 words) - 07:13, 17 April 2024
  • Navigation: User Guide ➔ Getting Started ➔ Tutorial ➔ Tutorial Videos Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links:
    5 KB (169 words) - 02:58, 5 April 2024
  • tools for model (SysCAD Project) optimisation. Python Example - Simple Unit Model Testing Framework - For validating model results when doing model development
    9 KB (976 words) - 18:59, 2 August 2023
  • want to set/get. For example GetDynTag(s) or GetDynTag(strcat(PipeTag, ".Qm (t/h)")). For SetDynTag() and GetDynTag() the checking of the tag validity is
    11 KB (632 words) - 18:26, 2 August 2023
  • only limited to the unit model variables, they can be also include driver tags. NOTE: Tag names are NOT case sensitive. A tag is NOT checked to see if
    13 KB (1,333 words) - 05:22, 7 February 2024
  • generating an Excel report and then find & correct any tags in Excel. Data Historian: If a tag has been added to the historian at any time (even if it
    8 KB (837 words) - 03:41, 27 March 2024
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ FlwSolve This tab page on the Plant Model Access Window has a number of parameters that the user may either
    6 KB (33 words) - 16:59, 2 August 2023
  • multi-layered screen model that replaces the original Screen model. It includes all of the features of the original screen model, as well as: Allows the
    20 KB (3,176 words) - 17:16, 2 August 2023
  • columns, but all the possible tags always work even if they are not visible on the access window display. If you have referenced a tag from the matrix (e.g. in
    36 KB (1,044 words) - 12:28, 9 January 2024
  • from Case 1. The Case1 Report is a SetTagList Report, as shown in Cell E6, the subsequent reports are SetTagListOffset reports. (The image below shows
    5 KB (767 words) - 15:22, 17 May 2023
  • Notes: The Makeup Block is a sub-model which is evaluated sequentially. The user can change the order that the sub-models are solved using the drop down
    75 KB (1,154 words) - 03:33, 5 April 2024
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ Range Check This tab page on the Plant Model Access Window allows the user to set up range check related
    8 KB (27 words) - 05:09, 7 February 2024
  • important inputs to the model can be set from the Model Criteria Inputs to the model are well laid out and comprehensive Results Reports: Model Criteria Output
    9 KB (1,479 words) - 12:12, 20 February 2024
  • SysCAD with the tags we want to adjust for opimisation set to these values, and return our calculated error. We have a list of optimising tag strings, and
    9 KB (842 words) - 09:06, 3 November 2022
  • be ignored. The Array class allows user to Get / Set numeric values only. Please see StrArray Class for getting/setting String values. None The examples
    20 KB (916 words) - 09:00, 10 May 2024
  • to change the model over to an alternate, improved model. During this grace period, discontinued models should still load and project will run as is. However
    2 KB (256 words) - 13:41, 23 October 2023
  • variables listed in the Standard constants list variables listed in the Special constants list variables listed in the Special variables list names used
    5 KB (143 words) - 01:32, 27 January 2023
  • Configuration File Sort either by DLL or Group: See Model Selection for more information on adding models to the configuration file. Insert into Project Flowsheet
    34 KB (2,555 words) - 05:12, 21 February 2024
  • the species database (see Boiling Point Elevation for Std Model), or the unit uses a species model with an Elevated Boiling point calculation, then the equilibrium
    26 KB (2,038 words) - 09:28, 2 February 2024
  • FeederTag@{Tag}{Comment("Expect a valid Feeder Tag (Class instance name)")} Bit ValidTag, ValidModelType, ValidReference@ string SourceConnector@{Tag}{Comment("Uses
    7 KB (812 words) - 00:02, 12 April 2024
  • Transmitter (category Models) (section Model Theory)
    access a tag directly. However, using the transmitter can improve the display of the control logic on a flowsheet and better represent the actual equipment
    11 KB (341 words) - 11:45, 21 February 2024
  • Improved options for setting tag text sizes in graphics for units and links. New Tag menu section on the Graphics menu for tag manipulation. Build 13306:
    57 KB (9,089 words) - 09:50, 11 March 2024
  • some tag changes have been made, you may need to fix referenced tags in controllers, etc. The solver may not start until you have resolved the tag name
    6 KB (1,009 words) - 16:41, 2 August 2023
  • Direct Contact Heater (category Models) (section Model Theory)
    NOTE: This model is being phased out and will be removed in future versions (refer to Discontinued Models and Dlls). In Build 139, to add this model to the
    18 KB (1,906 words) - 09:24, 2 February 2024
  • conversion family specifies the group of conversions the tag belongs to. It also allows setting/getting the tag value correctly from Trends, Excel, etc. using any
    24 KB (1,906 words) - 03:11, 2 May 2024
  • display the SolutionImpurities in the Plant Model - Views tab page or from the Include Properties dropdown list on the first page of the material flow section
    6 KB (758 words) - 11:39, 20 February 2024
  • "Species_With_Flow" list. The "Species With Flow" list is then compared to the full species list, thus creating a "Species No Flow" list by difference. The
    8 KB (1,044 words) - 13:39, 23 October 2023
  • Reaction Block Summary (category Sub-Models)
    Project User Value 1 (set in Plant Model) (equivalent to Q) Val(2) = reference to Project User Value 2 (set in Plant Model) (equivalent to K') C_Li = a previously
    26 KB (2,722 words) - 03:26, 5 April 2024
  • the way the project runs. The "models".cfg, SysCAD.93.db3 and ModelData.db3 files contained data related to the process model library (tanks, pipes etc.)
    10 KB (412 words) - 12:09, 20 February 2024
  • Shows the use of ChemApp Model Configuration. Shows the use of ChemApp Direct Calc Model Shows the use of ChemApp Side Calc Model Shows the use of ChemApp
    26 KB (3,454 words) - 01:10, 23 October 2023
  • their own model procedures (MP) to be evaluated as part of some unit models. It is like having a PGM inside a Tank, Tie or Pipe model where the code is
    11 KB (1,683 words) - 01:57, 6 September 2023
  • will get 100 t/h coming out to the sink XPG_002. In Steady State (and Transfer Push) the flow is effectively controlled at the inlet. The same model in Dynamic
    8 KB (1,269 words) - 11:05, 30 November 2022
  • fetch values local to the current Tie model. Therefore when fetch values, unit Tag name is not used. Use the Get() function to retrieve values from SysCAD
    2 KB (268 words) - 11:01, 22 May 2023
  • from Case 1. The Case1 Report is a SetTagList Report, as shown in Cell E6, the subsequent reports are SetTagListOffset reports. (The image below shows
    5 KB (685 words) - 10:14, 6 September 2021
  • the IO list: The IO List (Marshal OPC Client Tag List) can be edited by editing the Marshal_Tags.db3 directly. This is where user defines the tag matching
    4 KB (564 words) - 10:14, 1 February 2024