Plant Model - RC

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ View ➔ Plant Model ➔ Range Check

FlwSolve Tab Settings Tab Audit Tab Project Tab RC Tab Species Tab Views Tab Soluble Tab WaterQuality Tab Qualities Tab
Environment Tab System Tab ModelList Tab Flowsheets Tab PrjNetworks Tab Status Tab Statistics Tab States Tab EvalSeq Tab Globals Tab

Introduction

This tab page on the Plant Model Access Window allows the user to set up range check related parameters.

Tag (Long/Short) Options Description/Calculated Variables

Range Checks

RC...
Action Off Never carry out any Range Checks - the user will not get any warnings if values are outside of their expected ranges. If this option is selected then none of the fields described below will be visible.
WhenNotBusy Do the Range Checks when the solver is not busy, i.e. when the model is stopped or paused.
Continuous Do the Range Checks at every iteration.
OnCount Do the Range Checks at specific iteration intervals - the interval is defined by the user.
WhenSolved Only available in a steady state project. Do the Range Checks when the project is solved.
Count Input The number of iterations/steps between each range check - this field is only visible if OnCount is chosen above.
RelMassTolerance Input The Relative Mass Tolerance value, as a percent, used to check if a stream has flow of the relevant species. If the flow of the species is less than this tolerance then no checks will be performed.
Mixture
Project.T Tickbox This enables a check of the unit or stream temperature against the maximum and minimum values specified in the project configuration file. (The maximum and minimum values specified in the project configuration file are displayed next to this tick box). Please see Temperatures and Pressures in the Project Configuration.
Project.P Tickbox This enables a check of the unit or stream pressure against the maximum and minimum values specified in the project configuration file. (The maximum and minimum values specified in the project configuration file are displayed next to this tick box). Please see Temperatures and Pressures in the Project Configuration.
BPE.T Tickbox This enables a check of the Boiling Point Elevation (BPE). Please see Boiling Point Elevation for more information on the BPE.
SaturationT Tickbox This enables a check of the Saturation temperature.
Density.Correction Tickbox This enables a check of the mass fraction of species with density corrections against the maximum mass fraction specified in the species database when using the Standard Species Model. Please see Density Correction in the Species Table for more information on the Density Correction function.
Density.NoSolvent Tickbox Only available in Build 138 or later. This enables a warning to be given if a species with a Density Correction function is present with no solvent. Please see Density Correction in the Species Table for more information on the Density Correction function.
Density.HiSolute Tickbox Only available in Build 138 or later. This enables a check of the mass fraction of species with density corrections against the maximum mass fraction specified in the species database when using the Standard Species Model. For each species, warnings will only be given if the Generate Warnings field in the Density Correction Function specification in the Species Database is 'On'. Please see Density Correction in the Species Table for more information on the Density Correction function.
Cp.LowLiq Tickbox This enables a check when using the Standard Species Model to ensure that stream specific heats are greater than a user defined value (see Cp.LowLiq.Value below). SysCAD allows users to enter negative Cp values for aqueous species only. This allows the aqueous species to lower the specific heat of an aqueous stream. However, if the aqueous species are more concentrated than expected, the stream Cp may become negative, which is physically impossible and this causes problems with the energy balance and temperature calculations. The following 2 fields are only visible if this Tickbox is enabled.
Cp.LowLiq.Value Input This is only visible if Cp.LowLiq is enabled. The user may enter lowest allowable Cp value in an aqueous stream. SysCAD will flag a warning if the Cp is below this value and Cp.LowLiq is enabled. It does not adjust the Cp value actually used.
Cp.LowLiq.Rule All Solutions When using the Standard Species Model, report errors for ALL liquid streams that have a Cp value lower than the value in the field above.
IgnoreIfNoH2O When using the Standard Species Model, report errors only for liquid streams that contain water AND that have a Cp value lower than the value in the field above.
This prevents users getting errors when they add a stream, either as a makeup or a normal stream, that contains only an aqueous species with a negative Cp.
VelLimit.ShowAs Off No velocity limit messages will be shown.
Note Velocity limit messages will be shown as notes.
Warning Velocity limit messages will be shown as warnings.
Error Velocity limit messages will be shown as errors.
VelLimit.Slurry Input Allows user to set an upper limit for slurry velocity. Messages may be displayed based on the VelLimit.ShowAs method selected. See the above field.
VelLimit.Vapour Input Allows user to set an upper limit for vapour velocity. Messages may be displayed based on the VelLimit.ShowAs method selected. See the above field.
Individual Species
The first 2 fields below allow the user to enable or disable specific heat (Cp) checks for INDIVIDUAL species, rather than for the total stream. These are for Standard Species Model.
Cp.T Tickbox If this is ticked, then SysCAD will check the temperature of the unit or stream against the extended temperature range, as specified in the configuration file. If the measured temperature is outside the species Cp extended temperature range, then SysCAD will give the user a warning. Please see Heat Capacity (Cp) in the Species Table for more information on the Cp function and Increasing the Temperature Range of a Species in the Species Configuration.
Cp.T.Tolerance Tickbox
  • If this is ticked, then SysCAD will NOT give the user a message if the temperature of the unit or stream is outside of the temperature range specified for the species specific heat (Cp) value in the species database, but within the extended temperature range.
  • If this is NOT ticked, and the measured temperature is outside the species Cp normal temperature range, but within the extended range, then SysCAD will give the user a message.

NOTE: If the measured temperature is outside the species Cp extended temperature range SysCAD will still give the user a warning.

H2O.CriticalTemp Tickbox If the tick box is checked and H2O liquid, H2O(l), is present and the stream temperature is above the Critical Temperature of water, SysCAD will give the user a warning.