Introduction

This tab page on the Plant Model Access Window has a number of parameters that the user may either set or read for Global settings. Most of the settings can also be made on the Audit page of any unit model.

Tag (Long/Short)
Input/Calc/Options
Description/Calculated Variables

AuditOptions

(also see Audit)

Audit.On Tickbox Switch the Total Mass and Energy Audit calculations on or off. If off, no Total Audit calculations will be performed or displayed.
ElemAudit.On Tickbox Switch the Elemental Audit calculations on or off. If off, no Elemental Audit calculations will be performed. This option is for debugging and is always unticked on project load.
AuditCheck.MassTol.Rel Display Relative tolerance for mass balance checks.
AuditCheck.MassTol.Abs Display Absolute tolerance for mass balance checks.
AuditCheck.HeatTol.Rel Display Relative tolerance for energy (heat) balance checks.
AuditCheck.HeatTol.Abs Display Absolute tolerance for energy (heat) balance checks.
Frequency
This setting determines when the Audit tests are performed.
EveryIteration Only available in a steady state project. Audit calculations are carried out at every iteration.
EveryStep Only available in a dynamic project. Audit calculations are carried out at every step.
WhenSolved Only available in a steady state project. Audit calculations will only be carried out when the project is solved.
WhenPausedOrSolved Audit calculations will only be carried out when the solver is not busy, i.e. when the model is paused or stopped.
------ All Options Shown
Basics.ShowExtra Tickbox Show Extended Audit Details on the Audit tab.
Streams.Collect Tickbox Collect and show Streams Audit Summary table on the Audit tab.
Elements.Collect Tickbox Collect and show Elemental Audit Table on the AuditEl tab.
Elements.ShowExtra Tickbox Show additional columns in the Elemental Audit Table on the AuditEl tab.
Species.Collect Tickbox Collect and show Species Audit Table on the AuditSp tab.
Species.ShowExtra Tickbox Show additional columns in the Species Audit Table on the AuditSp tab.
Messages.OnError Tickbox Report audit errors to Messages Log in addition to Conditions window.
Pause.OnMassError Tickbox Pause model if a mass balance error occurs. This option is for debugging and is always unticked on project load.
Pause.OnElemMassError Tickbox Pause model if an elemental mass balance error occurs. This option is for debugging and is always unticked on project load.
Pause.OnHeatError Tickbox Pause model if a heat (energy) balance error occurs. This option is for debugging and is always unticked on project load.
Elements.DisplayTol.Rel Input Relative display tolerance for elemental mass imbalances.
Status - List worst tag and error

Audit

MaxError.Qm.Tag Display Displays the SysCAD Stream that carries the maximum Mass Balance error - only works if Audit is switched on.
MaxError.Qm.Rel Display Displays the above stream's relative Mass Balance error - only works if Audit is switched on.
MaxError.Qm.Abs Display Displays the above stream's Absolute Mass Balance error - only works if Audit is switched on.
MaxError.Hf.Tag Display Displays the SysCAD Stream that carries the maximum Energy Flow Error - only works if Audit is switched on.
MaxError.Hf.Rel Display Displays the above stream's relative Heat Balance error - only works if Audit is switched on.
MaxError.Hf.Abs Display Displays the above stream's Absolute Heat Balance error - only works if Audit is switched on.