Plant Model - Views

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ View ➔ Plant Model ➔ Views

FlwSolve Tab Settings Tab Audit Tab Project Tab RC Tab Species Tab Views Tab Soluble Tab WaterQuality Tab Qualities Tab
Environment Tab System Tab ModelList Tab Flowsheets Tab PrjNetworks Tab Status Tab Statistics Tab States Tab EvalSeq Tab Globals Tab

Introduction

This tab page allows the user to set the display options for stream / content properties display.

Data Section

Tag (Long/Short) Input / Options Description

Additional Properties to Include

PropertyOptions...
Energy Tickbox If this is enabled then Energy Flow Properties will be added to the project (except for the Values at User defined Temperature and Pressure). These will be visible for all streams. Otherwise they will be removed from the project (except for the Values at User defined Temperature and Pressure).
Saturation Tickbox If this is enabled then Saturation variables will be added to the project. These will be visible for all streams. Otherwise they will be removed from the project.
pH_Estimate Tickbox If this is enabled then Acidity (pH) variables will be added to the project. These will be visible for all streams. Otherwise these variables will be removed from the project.
Charge Tickbox If this is enabled then Charge variables will be added to the project. These will be visible for all streams. Otherwise these variables will be removed from the project.
Transport Tickbox If this is enabled then Transport Properties (including viscosity) will be added to the project. These will be visible for all streams. Otherwise they will be removed from the project.
DensityCorrections Tickbox If this is enabled then additional Density Correction variables will be added to the project. These will be visible for all streams. Otherwise these variables will be removed from the project.
HeatsOfCombustion Tickbox If this is enabled then additional Heats of Combustion variables will be added to the project. These will be visible for all streams. Otherwise these variables will be removed from the project.
ValuesAtUserTandP Tickbox If this is enabled then Values at user defined temperature and pressure will be added to the project. These will be visible for all streams. Otherwise they will be removed from the project.
SolutionImpurities Tickbox If this is enabled then Solution Impurity variables will be added to the project. These will be visible for all streams. Otherwise they will be removed from the project.
H2OProperties Tickbox If this is enabled then H2O Properties will be added to the project. These will be visible for all streams. Otherwise they will be removed from the project.
WaterQuality Tickbox If this is enabled then a new Water Quality tab page will be displayed to show additional settings and Water Quality variables will be added to the project. These will be visible for all streams. Otherwise these variables will be removed from the project.
UsrDefT Input The user defined temperature for use with the ValuesAtUserTandP group of variables.
UsrDefP (SaturationP) Input The user defined pressure for use with the ValuesAtUserTandP group of variables. If this is left as a * then the saturation pressure will be used.

Material View Options

(Sp and DSp Page)

SpViewOptions... Display Options (Saved in CfgFiles folder):

NOTE: The following display options are saved in the Cfgfiles\xxxx.Options.ini file, where xxxx is the name of the configuration file. All projects using the same configuration file will use the same saved settings. If the xxxx.Options.ini file is deleted, the display options will revert to default settings.

StreamColumnCount ValidRange:2-6 This allows user to specify how many columns of data are displayed in the stream species (Sp) Tabs. The default is 3 columns, one column will always display mass flow, users can choose what to display on the other columns. See Species Flow Section
Note: This value is set in the Project Configuration and therefore all projects using the same configuration will have the same number of columns visible on the Sp page of Links.
ContentColumnCount ValidRange:2-6 This allows user to specify how many columns of data are displayed in the content species (Sp) Tabs. The default is 3 columns, one column will always display mass, users can choose what to display on the other columns. Eg: Tank content in Dynamic Mode.
Note: This value is set in the Project Configuration and therefore all projects using the same configuration will have the same number of columns visible on the Sp page of Units that have Content tabs.
ImageColumnCount ValidRange:2-4 This allows user to specify how many columns of data are displayed in the image species (PSp) Tabs. The default is 2 columns. Eg: Tank Preset Image in Dynamic Mode..
Note: This value is set in the Project Configuration and therefore all projects using the same configuration will have the same number of columns visible on the Sp page of Units that have Image tabs.
Display Options (Saved in BaseFilesUser folder):

NOTE: The following display options are saved in the BaseFilesUser\SysCAD.User.Name.ini file - [SpeciesView] group. All projects used by the user will use these settings. If the SysCAD.User.Name.ini file is deleted, the display options will revert to default settings.

PageLayout
(See Species Flow Section)
See Note 1.
One The Species, Component or Elemental information will be shown on the Sp Tab based on what is chosen in "Select" list.
Two-Always The Species information will be shown with two Tabs, Sp where user can access species information by phase and EC where user can access Elemental and/or Components view.
Two-Optional The Species information will be shown with one or two tabs, EC Elemental or Components view is optional and can be shown/hidden by the user. This is the default setting.
ShowEC_Page Tickbox This is only visible if the page layout is two pages.
This is a Global User setting, so ticking this box will show the EC page in ALL SysCAD projects on the same computer.
ShowComponents Tickbox This is only visible if the page layout is two pages.
This is a Global User setting, so ticking this box will show the components information in ALL SysCAD projects on the same computer.
ShowIons Tickbox
BasisPerColumn Tickbox If not ticked, then all column views will have the same basis (All, by phase and so on), if ticked, then each column can have different basis.
This is a Global User setting, so ticking this box will change the basis in ALL SysCAD projects on the same computer.
UseGroupConversions Tickbox If ticked, then each column will have the same conversion units, if not ticked, then each field within the same column can have different conversion units.
This is a Global User setting, so ticking this box will change the basis in ALL SysCAD projects on the same computer.
ResetToDefaults Button Pressing this button will change the Material View Options to the default settings.

Additional Display Comments

DisplayOptions...
General Display Button States (Saved in BaseFilesUser folder):

NOTE: The following display options are saved in the BaseFilesUser\SysCAD.User.Name.ini file - [General] group. All projects used by the user will use these settings. If the SysCAD.User.Name.ini file is deleted, the display options will revert to default settings.

DisplayLongTag Tickbox Check this to use long variable tags. Equivalent to pressing the Tag:Long button on the access window.
DisplayLongSpeciesTag Tickbox Check this to use long Species Names. Equivalent to pressing the Species:Long button on the access window.
HideZeros Tickbox Check this to hide species with no flow. Equivalent to pressing the Hide Zero button on the access window.
TCE.HideZeros Tickbox For TCE unit models only. Check this to hide species in TCE unit models with no flow. Equivalent to pressing the Hide Zero button in TCE unit models.
Links.TableInfo Basic The links table will be displayed with basic information only, these include Mass flow and Temperature in steady state mode, and additional mass column in dynamic mode.
Detailed The links table will be displayed with additional information, including volumetric flow, pressure, total heat of formation, connection information and link type.
Additional Display Comments (Saved in CfgFiles folder):

NOTE: The following display options are saved in the Cfgfiles\xxxx.Options.ini file, where xxxx is the name of the configuration file. All projects using the same configuration file will use the same saved settings. If the xxxx.Options.ini file is deleted, the display options will revert to default settings.

ShowUserFormulas Tickbox If this is enabled then the User Property Calculations formulas for the user defined calculations, set up in the Configuration file, and will be visible next to the calculated values on all the streams. ViewUserCalc.png If this is disabled then the user defined calculations will still be visible, but the actual formulas will not be displayed. (See notes below.)
ShowSpFormulas Tickbox If this is enabled then the Species Calculations formulas for the user defined calculations, set up in the Configuration file, and will be visible next to the calculated values on all the streams. ViewSpeciesCalc.png
If this is disabled then the user defined calculations will still be visible, but the actual formulas will not be displayed. (See notes below.)

NOTES:

  1. This value is a Global User setting for SysCAD and therefore ALL SysCAD projects on the same computer will have the same number of pages visible.
  2. Available from Build 139.37028. The ShowUserFormulas checkbox is displayed at the bottom of the User Property Calculations section, allowing users to easily toggle the display.
    ViewUserCalc2.png
  3. Available from Build 139.37028. The ShowSpFormulas checkbox is displayed at the bottom of the Sp/EC tabs, enabling users to toggle the display easily.
    ViewSpeciesCalc2.png