Search results

Jump to navigation Jump to search
  • to do the following: ; 1) Define the column number to use for test data ; 2) Sets the test data by executing SetTags (this is equivalent to pressing the
    19 KB (907 words) - 02:09, 21 February 2024
  • and [math]\displaystyle{ V_2 }[/math] Measured, Previous or Target Values in SysCAD SI Units [math]\displaystyle{ e_a = V_1-V_2 }[/math] Absolute error
    12 KB (2,123 words) - 10:57, 13 February 2024
  • For example, the user cannot configure the flash pressure required in the Flash Tank, as the Flash Train will calculate this. If the user has a Tie in a
    8 KB (1,137 words) - 09:43, 1 February 2024
  • if the user selects the 'Whiten Crusher' method. Selection/Breakage - The fields visible if the user selects the 'Selection/Breakage' method. Test Data -
    35 KB (768 words) - 04:54, 14 May 2024
  • General Options Colours (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ Tools ➔ General Options ➔ Colours NOTE: The colour layers are in the order of importance, as shown in the following
    8 KB (97 words) - 23:44, 24 March 2024
  • \dfrac{1}{2dev} }[/math] (if Tavg - dev <= t <= Tavg + dev) Gaussian: [math]\displaystyle{ P(t) = \cfrac{1}{dev\sqrt{2\pi}}\cdot e^{\dfrac{-(t-Tavg)^2}{2dev^2}}
    25 KB (626 words) - 01:43, 6 September 2023
  • project is solved. Step 2: Insert unit operations Set Tag List and Get Tag List Step 3: Create 2 csv files, one containing the User Defined values for the
    19 KB (2,641 words) - 03:13, 7 February 2024
  • Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Unit Test Framework Unit Testing is important. Running a model to compare previous
    7 KB (993 words) - 18:34, 2 August 2023
  • the user to have a large amount of data available. Test data giving the crusher product size distribution for a given feed distribution. The user is required
    23 KB (1,654 words) - 09:30, 2 February 2024
  • the model would give the user a warning: SFW wash loss 7.5 is out of user specified range of data points (0 to 5) User without test data may set up a simple
    17 KB (1,773 words) - 04:11, 21 February 2024
  • Solve the project in its current build SysCAD 9.2. The last released Major build in SysCAD 9.2 is Build135, user should make sure the project is solved and
    9 KB (1,253 words) - 04:25, 16 November 2023
  • SysCADxxx\BasefilesUser\Conversions.db3 SysCADxxx\BasefilesUser\Symbols\*.* SysCADxxx\BasefilesUser\SysCAD.Machine.ini SysCADxxx\BasefilesUser\SysCAD.User.xxxx.ini
    13 KB (1,190 words) - 03:38, 5 April 2024
  • requires the user to have a large amount of data available. Test data giving the Mill product size distribution for a given feed distribution. The user is required
    23 KB (1,686 words) - 09:39, 2 February 2024
  • Therefore, please take care when using 'QProd', and if necessary test the values by displaying test values from different functions. As an example, when using
    20 KB (1,014 words) - 01:44, 6 September 2023
  • required to be able to insert these models into a project, it is required if the user wishes to use any of the PSD methods within the models. Some models require
    62 KB (2,065 words) - 03:33, 23 April 2024
  • may be useful if the user is in the feasibility study phase where the SysCAD flowsheet can remain untouched and many sets of test cases need to be performed
    11 KB (986 words) - 03:35, 5 April 2024
  • Build " & App.VersionNumber(2) & "." & App.VersionNumber(3) Application.StatusBar = "Started " & Version 'MsgBox Version '== Test Build number, and Exit if
    8 KB (1,059 words) - 17:42, 2 August 2023
  • then the user can access the Solver Setup (ProBal) dialog box to set the solve options. If one of the Dynamic modes is selected, then the user can access
    8 KB (1,102 words) - 05:10, 7 February 2024
  • value to 2 (Acid). Each item in the EnumDropList has an integer value. The names in the EnumDropList list need to be globally unique. If the user does not
    14 KB (1,480 words) - 06:26, 19 April 2024
  • er})^2} {\operatorname{MaxI} - \operatorname{MinI}} }[/math] Examples - GC_1.value1 = 100: GetSqr(GC_1.value1,0.2) ;returns 400. Thus (10*0.2)^2 GetSqr(GC_1
    33 KB (5,359 words) - 10:13, 1 February 2024
  • recommended. The user specifies how many tables of data are required (maximum is 500), the frequency of reporting (each table may be reported at a user specified
    15 KB (689 words) - 00:24, 17 April 2024
  • "_Y_", 3) ;r = "SysCAD" (nothing to replace) r = StrReplaceFrom(s, "s", "_Y_", 2) ;r = "Sy_Y_CAD" (case sensitive) w = StrLen(s) ;w = 6 r = StrUpr(s) ;r = "SYSCAD"
    19 KB (494 words) - 08:06, 13 May 2024
  • alert the user to this. Please refer to section Hints and Comments for more comprehensive hints on how to troubleshoots the controller, user can also have
    34 KB (2,509 words) - 03:27, 5 April 2024
  • either be the Feed or the Product Temperature (for methods 2 and 3), depending on which value the user has selected. Notes for "Loss to Ambient 4" The pipe may
    36 KB (1,127 words) - 03:33, 5 April 2024
  • opening any dynamic projects, user must first edit the configuration file to select the dynamic solve mode, alternatively, user can select to edit the configuration
    8 KB (1,304 words) - 05:00, 5 October 2023
  • Find Units using Query (category User Interface)
    Navigation: User Guide ➔ Edit ➔ Find Units using Query Related Links: Quick Find This feature allows user to search Any SysCAD variable using TagSelect
    13 KB (750 words) - 16:01, 2 August 2023
  • Navigation: User Guide ➔ COM Automation ➔ C++ Automation Below is a C++ source code that can be compiled to a console application. The example is similar
    6 KB (666 words) - 18:13, 2 August 2023
  • these occur as Halite (NaCl), Sylvite (KCl), Bischofite (MgCl2.6H2O), and Carnallite (KCl.MgCl2.6H2O). Exactly which species are produced in crystallisation
    13 KB (1,431 words) - 02:29, 3 October 2023
  • location. See also: How do I send a project to another user? How do I open a project sent from another user? Why can't I open the OLI project created by others
    11 KB (1,703 words) - 05:19, 28 March 2024
  • DotProduct = y.inner(y2) ;sum of each element y_i * y2_i, returns 45068 EndSub ;Logic d = a.GetLen() ;gets the array length a.SetAll(2.2/2) ;sets all elements
    20 KB (916 words) - 09:00, 10 May 2024
  • QFeed and QProd to Compressor, Valve 2, Pump 2, Piping System Model and Pressure Exchanger. Improved management of user selection of conversion units in the
    114 KB (16,094 words) - 02:05, 24 April 2024
  • distribution data can be defined as Overall Test Data (PRIMARY_MILL) or Individual Test Data (SECONDARY_MILL). The Crusher2 unit model is used to emulate the mill
    7 KB (1,026 words) - 10:45, 22 May 2023
  • quick test is to see if you can create (and then delete) a folder or file in the license folder, if you can't then you don't have the appropriate user permissions
    12 KB (1,768 words) - 09:54, 1 February 2024
  • ➔ Screen 2 The Screen 2 model allows the user to specify a single screening unit with a number of individual decks, up to a maximum of 8 decks. The user must
    20 KB (2,817 words) - 05:37, 14 May 2024
  • the General Separator is unimportant. The user may connect the streams to any position on the unit. If the user disables the unit, by un-ticking the On tick
    6 KB (942 words) - 09:26, 2 February 2024
  • type of tank (for example, CSTR). For this type of tank, the user may define additional user variables, then define some correlations (functions or subroutines)
    46 KB (4,504 words) - 01:29, 12 March 2024
  • we can then assign values: XIn = (c_double*3)() XIn[0] = 0.01 XIn[1] = 0.2 XIn[2] = 0.0 Finally we can actually call the function: rate = pd.rateFn(T, P
    11 KB (1,786 words) - 18:53, 1 September 2022
  • a dynamic matrix and manipulate its elements. The user may read in a matrix from a text file. The user may set constant values into a matrix when it is
    36 KB (1,044 words) - 12:28, 9 January 2024
  • may contain user defined individual phases. However, the phase description must match what has been defined in the species database. User must check the
    8 KB (79 words) - 23:14, 25 May 2021
  • }[/math] [math]\displaystyle{ U2 = U1^2 \left(1 + CV^2\right) }[/math] [math]\displaystyle{ U3 = U1^3 \left(1 + 3 CV^2\right) }[/math] The massecuite at
    29 KB (2,700 words) - 09:37, 2 February 2024
  • [math]\displaystyle{ C(x) = 1-\left(\cfrac{K_2-x}{K_2-K_1}\right)^{K_3}, \qquad K_1 \lt x \lt K_2 }[/math] Where the parameters K1, K2 and K3 can be entered directly
    14 KB (1,789 words) - 04:42, 14 May 2024
  • 3. SysCAD 9.2 Build 135 is the last release of SysCAD 9.2. Please see Revision History for SysCAD 9.2 for details on changes in SysCAD 9.2 versions. SysCAD
    33 KB (5,180 words) - 11:24, 14 February 2024
  • Navigation: User Guide ➔ Edit ➔ Project Configuration (cfg File) ➔ Calculation Configuration ➔ User Property Expressions NOTES: Function SumPhase() has
    15 KB (79 words) - 23:14, 25 May 2021
  • equivalent to Real a1*, b1* INTEGER a2{result}, b2{r} ; a2 and b2 are result fields - equivalent to INTEGER a2@, b2@ Real a3{c}, b3{r,c} ; a3 is a concealed
    24 KB (1,906 words) - 03:11, 2 May 2024
  • From within the Configuration Editor at Step 2 of 2, double click on a species or click on the Edit User Database button. In the 'Project Configuration'
    21 KB (3,316 words) - 04:42, 6 September 2023
  • [math]\displaystyle{ \operatorname{erf}(z) = \dfrac{2}{\sqrt{\Pi}} \,\int\limits_{0}^{z} \, e^{-t^2} \, dt }[/math] Recovery to underflow for a given solid
    943 bytes (400 words) - 09:58, 22 December 2021
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ Settings This tab page on the Plant Model Access Window has a number of parameters that the user may either
    11 KB (32 words) - 17:10, 2 August 2023
  • from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes for a list of new features and changes from SysCAD 9.1 to SysCAD 9.2 Build 131. Allows
    13 KB (2,038 words) - 19:09, 2 August 2023
  • is running. The user specifies how many tables of data are required, the frequency of reporting (each table may be reported at a user specified time) and
    17 KB (1,542 words) - 19:04, 2 August 2023
  • stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator
    7 KB (1,469 words) - 03:58, 24 April 2024
  • Navigation: User Guide ➔ Reports ➔ Archive Reporter ➔ Archive Editor The Archive Editor is used to define the user requirements for the Archive Reporter
    9 KB (1,122 words) - 16:58, 2 August 2023
  • Solver Setting - Tears (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ Tears Related Links: Tear, Convergence Methods, Tolerance Testing The Tears Summary lists
    7 KB (246 words) - 12:54, 17 May 2023
  • while loop, tags PC_001 to PC_014.Agglom.Rate.Correction will be set to the user defined value. ;The function IntStr0 will convert integers "1 to 14" to 3-character
    5 KB (293 words) - 23:54, 9 April 2024
  • Exchanger, Barometric Condenser). The user does not have to set any variables to make this functionality work. When the user connects and configures the unit
    14 KB (1,996 words) - 01:30, 6 September 2023
  • second section allows user to specify method and tolerances values for the tear block. Convergence - The third section allows user to specify the tolerances
    33 KB (570 words) - 05:54, 5 December 2023
  • Solver Set up for Dynamic Projects (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ Solver Setup (Dynamic) Related Links: Solver Set up for Steady State Projects NOTES: This command will display
    7 KB (94 words) - 06:18, 16 April 2024
  • configuration file Edits the user species database with reference to the selected configuration file Edits the user conversion database Tests the species database
    11 KB (1,270 words) - 02:55, 5 April 2024
  • Controls Window (redirect from Trend Window (for PID2 Controllers)) (category User Interface)
    Navigation: User Guide ➔ Windows ➔ Controls Window Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Control Commands, Controls
    7 KB (520 words) - 07:19, 17 April 2024
  • Recycle O2(g) Reactions: 1 FeCO3(s) + 1 H2SO4(aq) -> 1 FeSO4(aq) + 1 H2O(l) + 1 CO2(g) Extent: Fraction FeCO3(s) = 0.44 4 FeSO4(aq) + 2 H2SO4(aq) + O2(g) =
    18 KB (1,466 words) - 02:47, 20 September 2023
  • cases without further user input. As is, this file is used to test the sensitivities of TWO variables. User can define the test value range for the two
    5 KB (767 words) - 15:22, 17 May 2023
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ Species This tab page on the Plant Model Access Window has a number of parameters that the user may either
    17 KB (32 words) - 00:20, 13 December 2023
  • Solver Setting - Dyn (category User Interface)
    information as well as allows the user to load in a historian tag list. NOTE: The first line in the Historian Tag list is ignored, user can place heading or comments
    7 KB (113 words) - 02:41, 16 January 2023
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ States Related Links: Plant Model - States - Full Detail The States tab page gives information on the time
    17 KB (38 words) - 18:16, 2 August 2023
  • Echo "Installing Notepad++" npp8.4.2.Installer /S Echo "Install script completed" Pause The following applies when user upgrades a SysCAD version or Major
    11 KB (1,674 words) - 05:32, 5 September 2023
  • Navigation: User Guide ➔ Solver ➔ Solver Methodology This section describes the methodology used by the SysCAD software to produce a solution for a user defined
    8 KB (1,292 words) - 18:27, 2 August 2023
  • Navigation: User Guide ➔ Frequently Asked Questions ➔ Installation Questions Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related
    6 KB (912 words) - 01:57, 6 September 2023
  • Solver Setting - Tolerances (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ Tolerances
    1 KB (9 words) - 04:43, 16 January 2023
  • For notes on upgrading SysCAD projects from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes and Revision History.
    20 KB (3,176 words) - 17:16, 2 August 2023
  • Navigation: User Guide ➔ Solver ➔ Constants There are a number of constants used in SysCAD in calculations, models or the solver. Wherever possible the
    2 KB (225 words) - 12:38, 21 November 2023
  • Navigation: User Guide ➔ Licensing ➔ USB License Key Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 SysCAD USB License Keys are used
    4 KB (793 words) - 05:56, 28 February 2024
  • General Separator, Thickener, Thickener 2, Multi-Stage Counter Flow Tie, Screen 2, Direct Contact Heater 2, Flash Tank 2, Evaporator, Hot Flash Tie An Evaluation
    10 KB (1,668 words) - 04:17, 25 September 2023
  • release of SysCAD 9.2 (31st July 2009). For notes on upgrading SysCAD projects from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes for
    57 KB (9,089 words) - 09:50, 11 March 2024
  • Solver Setting - GlobalTear (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ GlobalTear Settings for convergence of recycle tears. Please see Convergence Methods
    9 KB (22 words) - 12:50, 5 December 2023
  • Project Settings (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ Edit ➔ Project Settings This command will open the Project Settings dialog box. NOTE: SysCAD must be stopped for
    10 KB (143 words) - 00:43, 5 April 2024
  • the tag being fetched is a string variable $ Example 2 [string] or GetDynStrTag is useful for users wanting to dynamically build up some control logic either
    11 KB (632 words) - 18:26, 2 August 2023
  • Process understanding, studies, optimisation Control system (e.g. PLC) testing Operator training There is currently one solver mode functionality add-on
    8 KB (1,102 words) - 04:41, 6 September 2023
  • Controlled and Referenced Variables (category User Interface)
    controlled will have a coloured arrow indicating this fact to the user. In addition to this, the user may right click on the tag and a menu will be visible with
    7 KB (855 words) - 02:06, 15 June 2021
  • Viscosity is Ns/m² User can use a number formats for entering viscosity data into the SysCAD database: Constant - User can enter a constant value Equations for
    11 KB (838 words) - 02:14, 9 November 2023
  • [math]\displaystyle{ S =\matrix{H_2 \\ CH_4\\ O_2\\ H_2O\\ CO\\ CO_2\\} \pmatrix{ 0 & 0 & 2 \\ 0 & 1 & 4 \\ 2 & 0 & 0 \\ 1 & 0 & 2 \\ 1 & 1 & 0 \\ 2 & 1 & 0 \\} \quad
    29 KB (4,645 words) - 23:31, 14 February 2024
  • Navigation: User Guide ➔ COM Automation ➔ Testing if SysCAD is Open in VBA Generally a COM Automation macro is written to start SysCAD, load a project
    4 KB (564 words) - 09:40, 9 February 2022
  • Navigation: User Guide ➔ Mass and Energy Balance SysCAD will always try to maintain a mass and energy balance. For information on how SysCAD calculates
    7 KB (982 words) - 02:06, 15 June 2021
  • Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Database Access Manually entering a lot of data into the database can be tedious
    2 KB (315 words) - 18:57, 1 September 2022
  • -rr[:, 0]**2/rr[:, 1] ## Affinity DeltaN2O4 = -np.diff(rp[:, 1]) ## Change in [N2O4] N2O4Term = k*(rp[:-1, 1]+rp[1:, 1])/2. ## Average value of [N2O4] in each
    4 KB (600 words) - 18:44, 1 September 2022
  • stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator
    9 KB (2,284 words) - 02:45, 14 March 2024
  • set nFC = -2, nC = 2 : [math]\displaystyle{ \left(\cfrac{A_o - A^*}{F}\right)^2=\left(\cfrac{A_o - A^*}{C}\right)^2 \times \cfrac{C^2}{F^2} }[/math] SAL
    33 KB (3,902 words) - 23:27, 22 February 2024
  • Graphics Symbols (category User Interface) (section BaseFiles and BaseFilesUser Symbols)
    BaseFilesUser\Symbols folder. The purpose of the ..SysCADxxx\BaseFilesUser\Symbols folder is for user defined symbols. For example, if the user creates
    19 KB (2,757 words) - 22:44, 12 May 2024
  • stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator
    9 KB (2,327 words) - 02:49, 14 March 2024
  • stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator
    9 KB (2,350 words) - 04:05, 28 March 2024
  • converged. Recycle Between Ties 1 0 1.0 2 0.5 1.5 3 0.75 1.75 4 0.875 1.875 5 0.9325 1.9325 .... 18 0.99999905 2 SysCAD has an implementation of the method
    16 KB (2,589 words) - 08:08, 24 November 2023
  • to SysCAD 9.2. For a full list of differences between SysCAD 9.1 and SysCAD 9.2, please refer to SysCAD 9.2 Release Notes. Install SysCAD 9.2. This should
    25 KB (4,079 words) - 10:09, 3 August 2023
  • Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Optimisation Related Links: Example Project - ChemApp with Python Optimisation
    9 KB (842 words) - 09:06, 3 November 2022
  • 75694246e+02, 1.76991503e+02, 2.72699554e+01, 1.28469206e+01, 6.32469251e-01, 2.60232738e+00, 5.87385513e-01, 1.45618792e+01, 5.32841733e-02, 2.42947148e+01, 4.20754018e-02])
    6 KB (857 words) - 04:19, 25 September 2023
  • Similarly, if T2 > TUpper Limit then: [math]\displaystyle{ \Delta H _{T_{upperlimit} \quad \; \to \; T_2} \; = Cp_{T_{upperlimit}} \quad *\left ( T_2 - T_{upperlimit}
    25 KB (1,870 words) - 09:58, 1 February 2024
  • configuration file. In Step 2 of 2, select the Calculations tab Follow instructions given in Calculation Configuration User can add customised species calculation
    14 KB (1,835 words) - 03:18, 5 April 2024
  • TagValue("FEED_ppm_SET.TC[1].User.Value")) ## Print another tag print ("Changing value to 45 ppm") Tags.SetTagValue("FEED_ppm_SET.TC[1].User.Value", 45) ## Change
    11 KB (1,558 words) - 18:42, 2 August 2023
  • Scenarios (category User Interface)
    model is to be used for scenario testing, it is recommended to save a scenario file for each test case performed, so that user can quickly recall the scenario
    8 KB (1,164 words) - 05:40, 5 September 2023
  • by the user. The Conveyor Belt will set the required capacity in the link between the conveyor and the upstream bin. A Shuttle conveyor with 2 or more
    32 KB (1,036 words) - 10:54, 22 February 2024
  • and very likely is referring to older version of the software. Navigation: User Guide ➔ SysCAD Version History ➔ Revision History for SysCAD 9.1 Build 127
    18 KB (2,754 words) - 03:55, 11 September 2023
  • Navigation: User Guide ➔ SysCAD Version History ➔ Build 138 Release Notes Latest SysCAD 138 Version: 2 March 2022 - SysCAD 9.3 Build 138.30470 Related
    12 KB (133 words) - 17:54, 2 August 2023
  • | Project Configuration - step 2 of 2 | Calculations: On the User Property Calculations section (top half), add two user defined properties to represent
    34 KB (2,555 words) - 05:12, 21 February 2024
  • [math]\displaystyle{ \beta_{ij,T} \propto \frac {S_{ij}^2}{S_j}.\left( 1-\frac {S_{ij}^2}{D_{max}^2} \right) }[/math] Where: [math]\displaystyle{ S_{ij} }[/math]
    39 KB (5,250 words) - 18:32, 2 August 2023
  • compounds would act in the same way. This should be reviewed based on real test data. Reagent concentrations, ratios and excesses were often assumed and
    6 KB (1,011 words) - 04:03, 8 September 2023
  • constants in the Rosenberg-Healy equation may be specified by the user by selecting the RosenbergUser option: [math]\displaystyle{ \alpha_0 }[/math] = ASat.a0 etc
    19 KB (552 words) - 14:10, 14 March 2024
  • SysCAD 9.2, What's New, Revision History The formal release date for SysCAD 9.2 Build 131.6369 is 30th July 2009. Since this release, SysCAD 9.2 Build 132
    19 KB (3,031 words) - 09:50, 11 March 2024
  • heat absorbed by the surrounding air, thus: (2) [math]\displaystyle{ \cfrac{L}{G} = \cfrac{h_2-h_1}{C(T_1-T_2)} }[/math] where: G = air loading, mass flow
    19 KB (1,556 words) - 04:18, 21 February 2024
  • method to allow user to selectively define which species is included in the elemental concentration count. For example, user can select Fe2+ only, not total
    19 KB (2,881 words) - 18:38, 2 August 2023
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ States ➔ Full Detail Related Links: Plant Model - States This page describes the extension of the States
    7 KB (61 words) - 09:55, 23 March 2023
  • cases without further user input. As is, this file is used to test the sensitivities of TWO variables. User can define the test value range for the two
    5 KB (685 words) - 10:14, 6 September 2021
  • (partial) Tag,Value SLURRY_IN.QmReqd (t/h),40 Feed_ppm_Set.TC[1].User.Value,40 Feed_ppm_Set.TC[2].User.Value,500 SLURRY_IN.Content.DLockup.[Au(s)].LockupReqd (%)
    10 KB (1,420 words) - 06:53, 19 February 2024
  • dKernel tab only shown when Agglom.Kernel.Type = User or Kernel Builder. With Agglom.Kernel.Type = User, [math]\displaystyle{ \beta }[/math] values are
    68 KB (396 words) - 01:37, 22 November 2023
  • unit tag names. New BaseFilesUser folder, along side BaseFiles folder, for all global user settings, user Symbols and user engineering conversions. BaseFiles
    16 KB (2,427 words) - 10:14, 1 February 2024
  • the user to specify a single heat loss factor. User can choose reference temperature to be the feed or product temperature. SuperHeat Loss : User can lose
    42 KB (6,030 words) - 18:10, 2 August 2023
  • Notes The user MUST have added and configured a PHREEQC Model Configuration unit in the SysCAD project before this unit can function. The user MUST have
    9 KB (1,933 words) - 04:05, 28 March 2024
  • CoO.Al2O3 132.0 132.2 0.174 0.75 ....... Fe2S3 117.9 47.8 59.468 0.57 Na2C2O4 132.0 34.0 74.248 0.99 2CaO.[Al2O3].8SiO2 567.1 97.7 82.781 0.82 CrO2 52.7
    36 KB (1,198 words) - 09:46, 21 July 2023
  • Navigation: Models ➔ Control 2 Models ➔ Transmitter The transmitter is used to pass a value to a PID block. Its use is not required since a PID can access
    11 KB (341 words) - 11:45, 21 February 2024
  • Navigation: Models ➔ Control 2 Models ➔ Actuator The Actuator is used to get a value from a PID block and then change the value of a tag in the model.
    5 KB (204 words) - 11:45, 21 February 2024