Search results

Jump to navigation Jump to search
  • control purposes. The following 3 models are the most common Control models used in both Dynamic and Steady State projects and are available with a standard
    62 KB (2,065 words) - 03:33, 23 April 2024
  • bring up a pop-up list of short-cut commands. There are three sets of commands available to the user, depending on the state of the SysCAD project. The
    9 KB (235 words) - 02:00, 24 April 2024
  • Project Configuration (cfg File) (category Project Configuration) (section Right Click Pop up List)
    user to make a duplicate of the configuration file and set it to a different solver mode. If a dynamic configuration file is created, "_Dyn" will be appended
    11 KB (1,270 words) - 02:55, 5 April 2024
  • configuration file is set up with a set of user-defined chemical compounds (via SysCAD Species Database and Configuration File). A process flowsheet is created by
    5 KB (726 words) - 03:40, 27 March 2024
  • of the SysCAD install. For a list of these example projects, please see: Example Projects To open and run these example projects, users must have a valid
    11 KB (1,067 words) - 00:41, 11 April 2024
  • April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Graphics, Graphics Commands, ETip: Graphics Window Drawing Grids A SysCAD project is built using Graphics
    13 KB (1,068 words) - 14:18, 2 August 2023
  • Guide ➔ Menu Commands ➔ Actions Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250
    7 KB (18 words) - 02:11, 9 August 2023
  • Guide ➔ Menu Commands ➔ Edit Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250
    4 KB (18 words) - 16:01, 2 August 2023
  • Library" and "SysCAD 9.3 Solver Library" when using SysCAD 9.3. The corresponding DLL and TLB files are installed with SysCAD. If you have multiple copies of
    9 KB (1,319 words) - 17:49, 2 August 2023
  • reorganised the 2 heading lines over 3 lines with the feedback report date on it's own line. Model improvements for dynamic projects: Added totaliser display tags
    114 KB (16,094 words) - 02:05, 24 April 2024
  • controller (PGM file) to assist the PID control. Set up PGM logic to set some of the following based on user-defined logic: Measured Tag Min and Max Range
    34 KB (2,509 words) - 03:27, 5 April 2024
  • General Configuration (category Project Configuration)
    normally only set up once when a project group is first started. The user will set the preferred operating mode, Steady State or Dynamic, temperature and
    9 KB (506 words) - 10:15, 3 August 2023
  • your installed copy of SysCAD. SysCAD 9.2 and SysCAD 9.3 - SysCAD 9.2 projects should be upgraded to SysCAD 9.3. It is possible to share a USB License
    9 KB (1,708 words) - 02:24, 17 April 2024
  • model. For dynamic projects this is used extensively to simulate the control system as well as operator actions. It can be used to simulate events, for example
    20 KB (1,211 words) - 03:31, 5 April 2024
  • SolveMode to : Dynamic". The project should now open in Dynamic mode. Save the project. The project is now ready for Dynamic project configuration / changes. Note:
    14 KB (2,360 words) - 03:06, 5 April 2024
  • case of SysCAD simulation is set up and solved, the user can set up such a file to read in feed conditions from MS Excel, solve the simulation, produce a
    9 KB (1,571 words) - 01:42, 15 June 2021
  • Batch Feed - this section is available on the first Tab in Dynamic projects. This allows users to set the Feeder to deliver a fixed amount of flow. VLE - Optional
    47 KB (2,683 words) - 09:04, 2 February 2024
  • different combinations of solver mode and add-on options selected - please see SysCAD Structure for more information on the solver and add-ons. A site may
    190 bytes (1,504 words) - 14:42, 9 June 2021
  • state projects, Reference Start Time = Time Zero (midnight January 1 1970) In Dynamic projects, Reference Start Time = Time as set in the Solver Set up for
    3 KB (172 words) - 16:43, 2 August 2023
  • replacement method for the Loss to Ambient Method. Added Loss to Ambient 5 method - this heat loss method accounts for scale build up, and solves for the surface
    7 KB (848 words) - 12:57, 31 July 2023
  • Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 NOTE: We recommend using the Archive Reporter for dynamic project reports. The archive reporter is
    8 KB (798 words) - 00:34, 1 July 2021
  • Reaction Editor. SysCAD 9.3 requires Reaction Editor version 1.2. The new Reaction Editor can be used with SysCAD 9.2 and SysCAD 9.3. For 9.3 reactions, it supports
    42 KB (6,030 words) - 18:10, 2 August 2023
  • network solver will not be simplified. Pipes in new projects will be simple by default. For upgraded projects, the "Simplify" option will need to be set in
    19 KB (3,031 words) - 09:50, 11 March 2024
  • 2024 - SysCAD 9.3 Build 139.35250 A brief description of the SysCAD workflow is as follows: A project configuration file is set up with a set of user-defined
    9 KB (1,479 words) - 12:12, 20 February 2024
  • therefore the connected OPC Server), refer to Solver Setting - FS Solver for more information. In SysCAD 9.3 when a scenario is loaded, the SysCAD values
    33 KB (5,359 words) - 10:13, 1 February 2024
  • ALL referenced objects are set to Nothing.. Set ProBal = Nothing Set Solver = Nothing Set Tags = Nothing Set Prj = Nothing Set App = Nothing End Sub Follow
    8 KB (1,059 words) - 17:42, 2 August 2023
  • previously in Edit - Solver Setup. Now require separate Project Configuration (cfg File) for Steady State (ProBal) and Dynamic projects shown in separate
    8 KB (1,113 words) - 11:50, 20 February 2024
  • Models ➔ Precipitator3 ➔ Data Sections Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Alumina 3 Bayer Species Model Unit
    68 KB (396 words) - 01:37, 22 November 2023
  • documentation. Example Projects distributed with SysCAD have been updated, including some new Example projects. Reduced memory use for projects allowing even larger
    19 KB (2,881 words) - 18:38, 2 August 2023
  • gov/software/phreeqc-version-3 for more information. SysCAD includes a demonstration version of PHREEQC. Using demo mode, demonstration projects for can be run and modified
    13 KB (1,646 words) - 02:26, 13 March 2024
  • number of the first reaction on that page. For example, if the reaction file contains 5 reactions, the first 3 may appear on the R1 page, then the next page
    51 KB (118 words) - 01:56, 19 April 2024
  • July 2009). For notes on upgrading SysCAD projects from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes and Revision History.
    20 KB (3,176 words) - 17:16, 2 August 2023
  • Build 13133: For dynamic projects, fixed error where start up options (Empty, Preset, etc) were corrupted when using the Project|Dynamic Setup... menu
    57 KB (9,089 words) - 09:50, 11 March 2024
  • ➔ Alumina Models ➔ Precipitation3 Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Alumina 3 Bayer Species Model The Precipitator
    13 KB (1,592 words) - 09:41, 2 February 2024
  • (ProBal) and Dynamic solver configuration. Two Access Windows are available and may be opened at any time: Access.1 is the default Access Window for unit models
    34 KB (1,045 words) - 23:50, 5 September 2023
  • Reporting Multiple Set Tag Error on the same variable Tag: Figure 2 - Message for Incorrectly Set Variable Any tag within a SysCAD project can be a Referenced
    7 KB (855 words) - 02:06, 15 June 2021
  • will bring up the Access Window for that tag. Right click on a message and a pop-up menu is shown: Access - activates the Access Window for the specified
    9 KB (1,228 words) - 10:38, 6 June 2023
  • always available; Nodes, Tears and Flows (Flows are only available for dynamic projects) information will be Off by default. The user may right click on
    23 KB (1,074 words) - 14:19, 2 August 2023
  • Reports and Import Data dialog box will bring up the following pop up list: For most of the options on the pop up list, they are simply an alternate method
    15 KB (1,320 words) - 11:47, 3 May 2024
  • contain data that that will be set in the output tags in the project. In the Example below the second column of data will Set the evaporation rate in the
    17 KB (1,330 words) - 05:32, 5 September 2023
  • Noise Controller (category Dynamic) (section Adding this Model to a Project)
    values generated. For the same seed value, a repeatable set of random numbers will be generated. For a different seed, a different set of random numbers
    13 KB (416 words) - 13:50, 1 February 2024
  • Commands for further information. In the View - Solver Settings, ProBal Tab, under Solver Start Actions uncheck SetTimeToZero. This can be set inadvertently
    8 KB (837 words) - 03:41, 27 March 2024
  • flowsheet (Dynamic mode) to specify a dynamic pond using embedded OLI calculations. OLI Legacy unit models: The following models are used for backward compatibility
    14 KB (2,278 words) - 02:07, 27 March 2024
  • See Solver Setting - Scenario tab page. NB the length of run can be set from the "Edit/SolverSetup" pop-up window, but you must use the "View/Solver Settings"
    4 KB (570 words) - 03:41, 27 March 2024
  • areas for that unit type will be deleted. The graphics for the fill area block will not be deleted. See below for how to remove the unwanted dynamic fill
    21 KB (1,196 words) - 10:05, 19 February 2024
  • may declare a matrix with a set of constant values. This allows the user to set up a table with known values for direct use (for example, as a lookup tabnle)
    36 KB (1,044 words) - 12:28, 9 January 2024
  • processor/s. The tag '$Solver.SolverThreadsRequired' in View - Solver Settings allows control of Multiprocessors for use by the network solver. The options are:
    20 KB (2,743 words) - 03:41, 27 March 2024
  • 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: What's New, Build 137 Revision History, Upgrading Projects SysCAD 9.3 Build 137 general release
    7 KB (139 words) - 18:34, 2 August 2023
  • Convergence Methods (category Solver) (section The need for damping)
    Navigation: User Guide ➔ Solver ➔ Convergence Methods Related Links: Tear, Solver Setting - Tears, Solver Setting - GlobalTear The SysCAD solver uses a "sequential
    16 KB (2,589 words) - 08:08, 24 November 2023
  • Reports ➔ Tag Select Reports Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Example SysCAD Excel Reports, Sensitivity Analysis
    29 KB (2,682 words) - 14:42, 3 April 2024
  • be selected for each individual column on the Sp page. If the BasisPerColumn option is NOT ticked, then the Basis can only be set once for all columns
    23 KB (1,392 words) - 10:18, 3 August 2023
  • Commands ➔ Graphics ➔ Copy & Paste Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Tag Copy and Paste, Graphics Symbols The Copy
    17 KB (2,348 words) - 05:11, 7 February 2024
  • start-up, when you press solve, SysCAD has a list of all tags used in SetTag() and GetTag() which it checks to see if they can ALWAYS be legally set/read
    11 KB (1,465 words) - 00:49, 19 January 2023
  • at the end of project solve, an example is given below. In this example we have used a user defined Class. This allows it to be used for any valid element
    5 KB (470 words) - 23:38, 20 February 2024
  • Separators are copied into the Excel report. The SysCAD_TagSelect statement is set up for the unit type in the Quick View window, in this case Pipes, or streams
    9 KB (1,024 words) - 18:54, 2 August 2023
  • Demo.spf\Project.spj' SysCAD = wc.DispatchEx(ProgID) ## Fire up SysCAD Prj = SysCAD.OpenProject(ScdDir+ScdPrj) ## Open project Tags = Prj.Tags Solver = Prj
    4 KB (600 words) - 18:44, 1 September 2022
  • species model can be set. Notes: The DEFAULT species model for the project needs to be set in the models configuration file (.cfg). For more information on
    14 KB (1,835 words) - 03:18, 5 April 2024
  • is on. See List Graphics Symbols for examples of how to use this. The default background scheme colour for SysCAD 9.3 is White. The user may select a different
    16 KB (2,028 words) - 03:06, 5 April 2024
  • Models ➔ Precipitation3 ➔ Model Theory (PSD) Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: Alumina 3 Bayer Species Model
    39 KB (5,250 words) - 18:32, 2 August 2023
  • tags can be checked for validity at solver startup or by CheckTags button. The functions [" "], GetTag and SetTag can be used. For numerical tags Conversions
    13 KB (1,333 words) - 05:22, 7 February 2024
  • file. So each Project Configuration (cfg File) can be used for either Dynamic OR Steady State, not both. This means any dynamic projects will need to be
    4 KB (913 words) - 11:50, 20 February 2024
  • SysCAD project are: Set up a SysCAD dynamic project. The project should have RealTime selected. Switch on the OPC Server option. See Project Project Settings
    4 KB (711 words) - 18:59, 2 August 2023
  • any opened projects and edit the project configuration file to include NH3(g) and NH3(aq) in the Display List. (See Species Configuration for further information
    12 KB (1,587 words) - 03:41, 27 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow Formally released as part of Build 139
    7 KB (1,712 words) - 04:04, 28 March 2024
  • release of Build 133. For notes on upgrading SysCAD projects from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes for a list of new features
    11 KB (1,683 words) - 01:57, 6 September 2023
  • Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow The PHREEQC solver is called to determine the state
    9 KB (1,933 words) - 04:05, 28 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow Released as a BETA version in Build 139
    114 bytes (1,749 words) - 13:23, 6 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: ChemApp SysCAD Project Workflow Formally released as part of Build 139
    6 KB (1,567 words) - 01:42, 13 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow Only available in Build 139.30807 or later
    5 KB (1,257 words) - 04:06, 28 March 2024
  • Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow The PHREEQC solver is called to determine the state
    8 KB (1,741 words) - 04:05, 28 March 2024
  • same results as Dynamic projects with the same parameters when run to steady state. See Preciptitator3 for sample results comparison. Project using species
    454 bytes (1,312 words) - 11:43, 25 May 2021
  • Model Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: OLI SysCAD Project Workflow Released as a BETA version in Build 139
    89 bytes (1,775 words) - 11:47, 21 February 2024
  • Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow The PHREEQC solver is called to determine the state
    11 KB (2,072 words) - 04:02, 28 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow Formally released as part of Build 139
    7 KB (1,742 words) - 04:05, 28 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow Formally released as part of Build 139
    6 KB (1,197 words) - 02:42, 14 March 2024
  • Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250 Related Links: PHREEQC SysCAD Project Workflow, Potash Evaporator, Evaporator The Evaporator
    9 KB (2,350 words) - 04:05, 28 March 2024
  • and changes from SysCAD 9.1 to SysCAD 9.2 Build 131. For notes on upgrading SysCAD projects from 9.1 to 9.2 see Upgrade to SysCAD 9.2. The new Simple Heat
    16 KB (2,427 words) - 10:14, 1 February 2024
  • separate the output based on individual phase or density. User can set up the unit for solvent extraction or organic stripping. The model also allows imperfect
    10 KB (1,809 words) - 02:50, 14 March 2024
  • 2024 - SysCAD 9.3 Build 139.35250 Related Links: OLI SysCAD Project Workflow, OLI Example Project Available from Build 139.31866. The above set of OLI unit
    9 KB (2,327 words) - 02:49, 14 March 2024
  • network model for green steelmaking. For Part 3, the focus will be on developing a fully trained convolutional neural network for dynamic simulation. Artificial
    29 KB (4,645 words) - 23:31, 14 February 2024