Search results
Jump to navigation
Jump to search
- Navigation: Models ➔ Common Sections ➔ Info This section is common to all model types. This section is common to all model types.8 KB (21 words) - 05:55, 10 July 2024
- Flange (section Data Sections)between two Feeder-Cross Page Connector units operating as cross-page connection. Access to Flanges can be found on the Links tab (Detailed view) of any20 KB (262 words) - 19:05, 2 August 2023
- Falling Film Evaporator (section Data Sections)FFEvaporator1 tab - Contains general information relating to the unit. HX tab - This second tab contains the Heat Exchange information. Info tab - Contains12 KB (788 words) - 09:40, 20 February 2024
- Sugar Juice Screen (section Data Access Page)JuiceScreen - The first tab page in the access window will have this name. Configuration and connection inputs and results are displayed on this page. The second16 KB (1,234 words) - 09:31, 2 February 2024
- Sugar Mud Filter (section Data Access Page)MudFilter - The first tab page in the access window will have this name. Configuration and connection inputs and results are displayed on this page. The second19 KB (1,462 words) - 09:39, 2 February 2024
- Sugar Crusher (section Data Section)Type: SugarCrusher - The first tab page in the access window will have this name. User inputs and results are displayed on this page. Add to Configuration20 KB (2,104 words) - 09:38, 2 February 2024
- OLI Sample Model (section OLI Sample Model tab page)solution. Parms tab - This tab lists the results for OLI parameters. Scale tab - This tab lists the scaling tendencies of the OLI solids. Info tab - contains22 KB (603 words) - 13:58, 23 October 2023
- OLI Reactor (section OLI Reactor tab page)Parms tab - This tab lists the results for OLI parameters. This tab is not visible if CalculateProperties is set to Minimal. Scale tab - Optional tab, only29 KB (675 words) - 13:58, 23 October 2023
- Sugar Fugal 2 (section Data Access Page)second tab page in the access window. Input Parameters, results and calculated data are displayed on this page. Class: Data - The second tab page in the28 KB (2,097 words) - 09:30, 2 February 2024
- Falling Film Evaporator 2 (section Data Sections)FFEvaporator2 tab contains general information relating to the unit. Results - This second tab contains unit results for the shell and tube side. VLE tab - Contains21 KB (1,534 words) - 09:40, 20 February 2024
- OLI Chemistry Model (section OLI Chem Model tab page)for configuring the model is: On the OLIChemModel tab page, browse for required .dbs file. On the OLIChemModel tab page, press the Init and Load button36 KB (1,383 words) - 13:58, 23 October 2023
- Sugar Vacuum Pan (section Data Sections)VacuumPan - The first tab page in the access window will have this name. Configuration and connection inputs and results are displayed on this page. The second29 KB (2,700 words) - 09:37, 2 February 2024
- Sugar Dryer (section Data Access Page)drier may be displayed on this page. The data display is turned on or off in the first tab (see display segment data above). The data is displayed in a matrix27 KB (2,749 words) - 09:23, 2 February 2024
- Sugar Fugal (section Data Access Page)second tab page in the access window. Input Parameters, results and calculated data are displayed on this page. Class: Data - The second tab page in the31 KB (2,776 words) - 09:33, 2 February 2024
- Sugar Crystalliser (section Data Access Page)tick box ShowSegementData is selected a tab named Data appears and displays a matrix of results for segments through the process. Data is displayed sequentially33 KB (2,960 words) - 09:37, 2 February 2024
- Blend Control (section Data Sections)detail in the following tables. The first tab contains general information relating to the unit. The second "ASSY" tab contains the settings for controlling3 KB (265 words) - 10:55, 22 February 2024
- all columns on the Sp page. The Basis and Display options for the Elements section of the EC page and the Components section of the EC page can only be850 bytes (307 words) - 08:55, 19 July 2023
- Models (section TCE Overview and Common Functionality)by the user and must be checked to ensure data used are correct. For help on the entering and modifying data in the SysCAD.93.db3 file, please see Species66 KB (2,139 words) - 01:17, 21 August 2024
- Falling Film Evaporator 3 (section Data Sections)FFEvap3 tab contains general information relating to the unit. Results - This second tab contains unit results for the shell and tube side. VLE tab - Contains30 KB (3,084 words) - 09:40, 20 February 2024
- Common Content Section (section WQ Tab Page)Views tab page or from the Include Properties dropdown list on the first page of the material Flow section. The values will appear on a new tab page called865 bytes (200 words) - 06:01, 9 January 2023
- PHREEQC Overview (redirect from PHREEQC - Common Data Sections)SysCAD.93.db3 file. The database is created using existing SysCAD data, PHREEQC Model data is not transferred to the SysCAD database. Once a SysCAD.93.db39 KB (1,409 words) - 01:17, 21 August 2024
- Navigation: Models ➔ Common Sections ➔ Material Flow Section ➔ Acidity (pH), Charge, Transport Related Links: Common Content Section This section is used2 KB (64 words) - 01:59, 16 July 2024
- to "default data tabs" (e.g. D1 for data, M1 or matrix and so on) or user defined tabs (if pagelabel is used within the PGM file). Info tab - Contains general20 KB (1,211 words) - 03:31, 5 April 2024
- Feeder-Cross Page Connector (section Content Tab Page)FeederSink - The first tab page in the access window will have this name. The Data section of the cross page connector changes depending on the Operation47 KB (2,683 words) - 07:00, 14 June 2024
- Define Species (DSp) Section (section DSp Data Section)Navigation: Models ➔ Common Sections ➔ Define Species (DSp) Section This Tab will contain a list of all of the species that are specified in the Project2 KB (255 words) - 09:38, 24 June 2024
- Navigation: Models ➔ Common Sections ➔ Material Flow Section ➔ Solution Impurities, H2O Properties Related Links: Common Content Section This section is1 KB (40 words) - 01:37, 16 July 2024
- Navigation: Models ➔ Common Sections ➔ Material Content Section ➔ Acidity (pH), Charge, Transport Related Links: Common Content Section This section is948 bytes (30 words) - 02:15, 16 July 2024
- TCE Species Mapping (section Common Error Messages)error conditions on the TCEModelCfg (1st tab), as shown in the AQSol example below . To fix the error, go to the TCEConfig tab (2nd tab) and press . This19 KB (2,877 words) - 02:27, 11 September 2024
- Access Window (section Data Entry in SysCAD)conversion units for the individual data field, at any time. Please see Conversions. When entering data into SysCAD data fields, the default mode is overwrite34 KB (1,071 words) - 03:54, 4 September 2024
- Navigation: Models ➔ Common Sections ➔ Material Flow Section ➔ Density Correction, Solubility, Saturation Related Links: Common Content Section This section973 bytes (30 words) - 02:04, 16 July 2024
- Navigation: Models ➔ Common Sections ➔ Material Content Section ➔ Solution Impurities, H2O Properties Related Links: Common Content Section This section858 bytes (30 words) - 02:15, 16 July 2024
- has chosen to display the Energy (Thermodynamic) Properties on the Plant Model - Views tab page.1 KB (60 words) - 06:02, 9 January 2023
- Navigation: Models ➔ Common Sections ➔ Material Content Section ➔ Density Correction, Solubility, Saturation Related Links: Common Content Section This992 bytes (30 words) - 02:14, 16 July 2024
- (Plant Model - Flowsheets tab page), then create the first Area if none and force any new graphics pages to belong to first Area. Added option to include123 KB (17,258 words) - 12:31, 22 August 2024
- FEM_Reaction option on the first page is NOT enabled then the following tab pages are NOT shown: FEM, Solver, Analysis, Results, VCS Data and QFEM. Unit Type:73 KB (3,653 words) - 05:20, 7 February 2024
- Simple Condenser (section Data Sections)- The first tab page in the access window will have this name. This page is only visible if the HXSizeCalc option is ticked on the first tab page. Add to23 KB (1,291 words) - 05:07, 7 February 2024
- Hydrocyclone (section Common Data Fields)Cyclone tab - This page contains all of the fields relating to the Hydrocyclone method. PartCrv tab - This tab displays the partition curve data for the49 KB (3,078 words) - 18:33, 22 August 2024
- project that uses the database, and clicks on the button in an Access window of a pipe or on the Content page, then the Species Short Name with individual19 KB (1,988 words) - 10:19, 1 August 2024
- User data, and just use the Hardwired data. To edit the user properties, either: Click on the 'Edit User Data' line in the list of available data; OR Double32 KB (2,138 words) - 05:10, 16 August 2024
- Makeup Block (MU) (section Data Section)sub-models are solved using the drop down lists on the first tab page - Off, On-AutoSequence, On-Sequence1, On-Sequence2, etc. The AutoSequence option will75 KB (1,154 words) - 03:33, 5 April 2024
- displayed on a new tab page in the Access window, with the page name matching the class instance name. The user does not need to specify PageLabel(xxx)46 KB (4,504 words) - 01:29, 12 March 2024
- Evaporator (section Data Sections)Examples. Unit Type: Evaporator - The first tab page in the access window will have this name. HX - Optional tab, only visible if an Internal Heat Exchanger7 KB (1,469 words) - 03:58, 24 April 2024
- Shell and Tube Heat Exchanger 2 (section Data Sections)The first tab page in the access window will have this name. This tab page is only shown if "Method=Condensing" and "Layout = Tube Detail". This tab page49 KB (3,135 words) - 06:46, 3 July 2024
- the syntax is as follows: 1. If the required variable is on the first tab page (or any page with same name) of the access window and not indented below13 KB (1,333 words) - 05:22, 7 February 2024
- Multi-Storage (section Data Sections)Optional tab, only visible if the TotalStore.Calculate option is enabled on the first tab page. The combined total of all stores. This series of tabs also25 KB (1,298 words) - 17:43, 2 August 2023
- FAQ - Species Related questions (section Can I perform a mass balance on a selected species easily?)input the data points directly into the Spline Table data without the need to first fit it to a curve. Repeat the above for Ca[OH]2(aq) Once the data has been14 KB (1,835 words) - 03:18, 5 April 2024
- PHREEQC Evaporator (section PHREEQCEvaporator tab page)ShowQRxnBypass is enabled on the TCE tab page. QFeed - Optional tab, only visible if ShowQFeed is enabled on the first tab page. This page shows the properties9 KB (2,350 words) - 15:55, 21 June 2024
- AQSol Evaporator (section AQSolEvaporator tab page)ShowQRxnBypass is enabled on the TCE tab page. QFeed - Optional tab, only visible if ShowQFeed is enabled on the first tab page. This page shows the properties9 KB (2,284 words) - 17:40, 21 June 2024
- database and replace it with the default SysCAD data. You may choose to overwrite the default data with your own data after the upgrade step. ALL SysCAD 9.2 databases25 KB (4,079 words) - 10:09, 3 August 2023
- Falling Film Evaporator 4 (section Data Sections)calculation Examples. Unit Type: FFEvaporator4 - The first tab page in the access window will have this name. The page contains the results fields. Add to Configuration33 KB (2,346 words) - 09:40, 20 February 2024
- OLI Evaporator (section OLIEvaporator tab page)is enabled on the TCE tab page. QBypass - Optional tab, only visible if ShowQBypass is enabled on the TCE tab page. QRxnBypass - Optional tab, only visible9 KB (2,327 words) - 17:28, 21 June 2024
- Calculation Configuration. LPC Tab (Leg Evaluation Block Solubility On) Select the Potash solubility System. NOTE the Potash Solubility data requires the Potash Addon15 KB (2,133 words) - 10:09, 3 August 2023
- be updated. One common example is XXX.Prod.HeatFlow is now XXX.HeatFlow (was shown on the Output tab page, now shown on the Results page). Once the projects9 KB (1,371 words) - 18:58, 2 August 2023
- Discussion: Annual Climate Data for Dynamic Modelling, Part III (section Using the Output Periodic Data)unit. Each of the outputs has a common period (one year) so we can select the CommonPeriod option on the first tab. Data for each of the signals is then8 KB (1,193 words) - 08:30, 14 July 2023
- Potash Evaporator (section Data Sections)PotashEvaporator - The first tab contains general information that can be set by the user. Results - This tab contains the unit results. HX - Optional tab, only visible33 KB (1,430 words) - 06:10, 24 April 2024
- statement as well as the table data. There are many examples of the tag select reports, these are documented on a separate page, please see Excel Tag Select24 KB (2,037 words) - 17:02, 2 August 2023
- SysCAD 9.2 Release Notes (category Outdated pages) (section Notes on Upgrading your 9.1 projects to SysCAD 9.2)equipment memo field on Info tab page of all models, which is ideal for longer descriptions in models. New link fields on Info tab page of all models, which19 KB (3,031 words) - 09:50, 11 March 2024
- Embedded Heat Exchanger (HX) (section HX Page)red in the above picture. If the user disables the unit, by un-ticking the On tick box, then the following actions occur: All streams connected to the 'Shell'1 KB (502 words) - 23:58, 15 January 2023
- Historian files - Histxxxx.xxx. Used to store data when historian is switched on. Various Project ini files Controls.Data (This was called Other.dat in Build 13814 KB (2,374 words) - 15:57, 9 July 2024
- Heap Leach (section Layers Tab Page)liquids data on the various layers in the heap. VLayers tab - Optional tab, only visible if the WithVapours option is enabled. Contains vapour data on the44 KB (1,891 words) - 03:59, 14 May 2024
- Discard Block (DB) (section Data Section)sub-models are solved using the drop down lists on the first tab page - Off, On-AutoSequence, On-Sequence1, On-Sequence2, etc. The AutoSequence option will112 KB (2,517 words) - 16:40, 2 August 2023
- LPrandtlNo). In a Dynamic Tank, the "SpeciesFilter" Filter.Method (on the Connect tab page) does not upgrade, as the possible selections with this option have21 KB (3,316 words) - 04:42, 6 September 2023
- Model, under the section "SSA" located on the Content or Qi tab page respectively; the user MUST tick the SetData box and enter the appropriate values,33 KB (3,902 words) - 23:27, 22 February 2024
- Signal Waveform (section User-Input Data)choice between: Data input as instantaneous Data Points or as interval Average Data Linear or Spline fitting between data points Data points at interval19 KB (1,298 words) - 05:23, 7 February 2024
- Build 135 Release Notes (category Outdated pages)display field on Audit page for Heat of Dilution contribution (for each species with HOD data) for change in dilution based on the common flow (i.e. minimum20 KB (3,176 words) - 06:28, 1 July 2024
- available. SatIdx of 100 for H2O(s) has been entered in the "PHREEQCConfig" tab. Salts First algorithm has been selected for species re-building in both Minteq_v427 KB (3,652 words) - 21:31, 31 May 2024
- Revision History for SysCAD 9.2 (category Outdated pages)new display field on Audit page for Heat of Dilution contribution (for each species with HOD data) for change in dilution for the common flow between inlets57 KB (9,089 words) - 06:28, 1 July 2024
- variable for added functionality. Some of the common keywords are summarised in the table below, Common Options for Variable declaration. A list of all24 KB (1,906 words) - 06:14, 2 June 2024
- Command Scripts (category Pages with syntax highlighting errors)processing or generating Excel Reports. If the Clear messages on run option is ticked on the Options tab of the Message Window, then even with this option ticked19 KB (907 words) - 02:09, 21 February 2024
- Discussion: Estimation of Specific Heat for Mineral Species (category Pages with syntax highlighting errors)For reference, you can see a SysCAD summary of common elements on the right. In this discussion page we will look at why this is so, how we can use this36 KB (1,198 words) - 09:46, 21 July 2023
- Manifold (section Data Sections)Examples for enthalpy calculation Examples. Unit Type: Manifold - The first tab page in the access window will have this name. Add to Configuration File10 KB (213 words) - 13:12, 9 February 2024
- description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here. If this field is blank, then1,002 bytes (104 words) - 05:37, 22 June 2023
- If not blank, this text will be displayed in the 'GenDesc' field on the first tab page of the unit. EquipMemo / EqpMemo Input A description of the unit5 KB (0 words) - 14:50, 26 May 2023
- embedded heat exchangers in the evaporator. This can also be changed on the first tab page. Type Fixed Heat Flow This will exchange a fixed amount of heat between7 KB (0 words) - 06:42, 23 April 2024