Common Data Sections
Jump to navigation
Jump to search
Navigation: Models ➔ Common Sections ➔ Info
Model Tab | Optional Input Content Tabs | Optional Material Content Tabs | Optional Material Flow Tabs | Common Tabs | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
UnitType | Content Section | DSp Section | Content | Sp | EC | Qo | Sp | EC | Info | Links | Audit |
Common Data on Info Tab Page
This section is common to all model types.
Tag(Long/Short) | Input / Calc | Calculated Variables / Options |
Documentation | ||
EquipDescription / EqpDesc | Input | Description of the equipment. If not blank, this text will be displayed in the 'GenDesc' field on the first tab page of the unit. |
EquipMemo / EqpMemo | Input | A description of the unit as a memo text field. This field is handled by SysCAD like a normal tag, therefore it can reported and set via Excel. |
Link1/2 | Hyperlinks | Hyperlink to a web page or file. There are two fields available for Hyperlinks. If a valid link is entered, the globe icon lights up and becomes clickable. Web pages should begin with http:// or https://, and files should begin with file://host/ (or simply file:/// for local files). |
EquipIdString / EqpIdStr | Input | Equipment identifier that can be used for reporting. |
EquipLocation / EqpLocation | Input | Equipment location identifier that can be used for reporting. |
ReportMe | Tick Box | Useful flag to reference to include/exclude models or pipes in Excel TagSelect reports. |
ReportKey | Input | Custom report key number - this may be used to select user defined keys for reporting. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field above, this will be displayed here. If this field is blank, then:
|
System Info | ||
UnitType | Output | The unique Type of the model. This will be identical to the title of the first tab page. Useful for selecting types of units/pipes in Excel TagSelect reports. |
UnitGroup | Output | A group that this UnitType belongs to - Unit, Control, Stream, OtherLink or Electrical. Useful for selecting groups of models in Excel TagSelect reports. |
DllName | Output | Each SysCAD unit-model is stored and distributed in a "dynamic-link-library" (dll). The name of the dll where the unit-model is stored will be displayed here for user information. |
SubTypeList | Output | List of all SubType sub models found in this model. There may be one or many of each SubType. These are primarily used in TagSelect for reporting and queries. |
AddOnsReqdList | Output | Some SysCAD unit-models require specific add-ons to load the model. For example, the Flash Tank 2 unit-model requires the HeatBalance Addon to load. If user does not have the "HeatBalance" add-on license option, then the project will fail to load. |
AddOnsUsedList | Output | Some SysCAD unit-models require specific add-ons to run the model. For example, the General Separator unit-model using Solids PSD Solids separation method requires the PSD Addon to run. If user does not have the "PSD" add-on license option, then the project will not solve using the PSD option. |
Settings and Options | ||
Mode:<Direct> or <InLine>, <Transfer Push> or <Transfer Pull> (Only available from Build 139 for selected models in Dynamic mode) | ||
Solution (This field may only be set in Dynamic mode.) |
Direct | Only solution option for models which do not allow surge, e.g. Pipe, Tie, etc. |
Inline | Solution option for models with surge, e.g. Tank, Tailings Dam, etc. | |
The following 4 fields are only relevant for some models (such as pipes) in Dynamic mode. Please see Dynamic Transfer for more information on Transfer simulation modes. | ||
FlowCalc | Transfer Push | In Transfer Push mode the pipes act as chutes where flow is instantaneously transferred from the source to the destination unit. |
Transfer Pull | In Transfer Pull mode simple networks are established, and this will determine the flow through the individual pipes. | |
FlowCalc.Apply | Available from Build 139. | |
FlowCalc.IterFwd | Display | |
FlowCalc.IterRev | Display | |
Procedures | Tickbox | The user may enable the Procedures functionality within certain units, e.g. Tanks, Ties, Pipes, etc. This allows users to embed control functionality within the unit. If enabled, a new tab page called MP will appear. Please see Model Procedures for further information. |
Active | Tickbox | Activates or Deactivates the unit operation. This is normally set by SysCAD when the user Activates or Deactivates an entire flowsheet, see Active Pages and Manipulating Graphics and Trend Windows for methods of Activating and Deactivating flow sheets.. |
Hold | Tickbox | Puts the unit operation on Hold so the solver ignores it when building a solution. |
SetState | Blank | No action required |
Complete_Reset | This option is effectively a combination of all the following SetState options. | |
Reset_Process | This will empty a pipe and flow values when the run begins. | |
Reset_Control | This will reset a controller back to 'Base' state, i.e. the same state as when the controller is first inserted into the project. This is mainly relevant for PID controllers. | |
Reset_Statistics | Selecting this will Reset the Statistics. | |
Reset_EventsProfiles | This will reset the Event or Profile back to start time. | |
Empty_Process | This Empties the unit if it has surge, e.g. if it is a Tank. | |
Preset_Process | This will preset the unit with the Preset data entered by the user. | |
Remove_Quals | This will clear the qualities information from all models and streams in a project. Used to clear unwanted qualities build up in recycle streams. See Remove Qualities for more information. | |
Copy_to_Preset | If the unit has surge, this will copy the current contents to the Preset image. | |
SetTimetoZero | Reset the starting time to zero. | |
SetAction (The State Action may also be set using the Options Button on the first tab page of the unit. |
Shown as button list, user can select any of the following actions (not all are available, depends on Solver Mode and Unit Type):
| |
InactiveOption | None | No action is taken when the model is placed in inactive mode. |
Reset | Only available in Steady-State (ProBal) projects. The process unit is reset when it is placed in inactive mode. | |
Empty | Only available in Dynamic projects. The process unit is emptied when it is placed in inactive mode. | |
Preset | Only available in Dynamic projects. Preset is used when it is placed in inactive mode. | |
Custom | Only available in Dynamic projects. Only selected models will have the "Custom" option. For example, in dynamic project a user may want to force or change valve/pump positions, or manipulate tank level and temperature. The purpose is for Marshal or XRefs or reports to see "meaningful" values. If "Custom" is used then the inactive model is "executed" each iteration but only to manipulate a few basic "custom" inactive options. | |
NodeStats.Generate | Tickbox | Toggles the NodeStats option on/off. If this is selected, individual unit's solver related statistical information will be display on the unit model's NodeStats tab page in the access window. |
Location.Count | Output | |
Location.Graphic | Output | The flowsheet the unit model is located on. |
Location.Area | Output | The area that the unit model is a part of. |
Network Info | ||
Network.Show | Available from Build 139. Analyse and show network in Find Result dialog box. | |
Marked | Tickbox | |
Network.ID | Output | The ID of the Network that the unit belongs to. |
Network.EvalNet | Output | |
Network.EvalOrder | Output | The Evaluation order of the unit set by the SysCAD Solver. |
LocalNetwork.Set | Only available in Dynamic projects. | |
LocalNetwork.Show | Only available in Dynamic projects. Analyse and show summary of local network. | |
LocalNetwork.Analyse | Only available in Dynamic projects. Analyse local network. | |
LocalNetwork.Find | Only available in Dynamic projects. Analyse and show local network in Find Result dialog box. | |
LocalNetwork.IDList | Output | Only available in Dynamic projects. |
LocalNetwork.IDSeqList | Output | Only available in Dynamic projects. |
Common Data on First Tab Page
This section is common to all model types.
Tag (Long/Short) | Input / Calc | Calculated Variables / Options |
---|---|---|
Tag | Display | This name tag may be modified with the change tag option. |
Condition | Display | OK if no errors/warnings, otherwise lists errors/warnings. |
ConditionCount | Display | The current number of errors/warnings. If condition is OK, returns 0. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here. If this field is blank, then SysCAD will display the UnitType or SubClass. |