Material Content Section

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: Models ➔ Common Sections ➔ Material Content Section

Material (Content) Content Tab Include Properties Species (Sp) Optional Tabs
Basic Information Energy
ValuesAtUserTandP
Density Correction
Solubility
Saturation
Acidity
Charge
Transport
HeatsOfCombustion
Heating Values
Solution Impurity
H2O Properties
Water Quality Sp Tab
EC Tab
DLockup
LockUp
DTrack
Track
DSz
Sz
MSz
DSSA
SSA

Related Links: Common Content Section, Calculation Configuration


Introduction

This section is used to display material content and all the associated properties. For example there will be a Content and M section in a Tank - Dynamic Mode.

This model primarily has read only variables, and a few options that affect how information (or views) are displayed. The species model that is used will affect the display and may result in some extra fields or tab pages. The default 'Standard' species model will be described here.

Content Tab Page

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Include Properties Button.png

Displays a list of properties that the user can view or hide by clicking on the required property.
Energy Fields related to Thermodynamic properties, e.g. Hz, Hs, Cp, etc.
Saturation Fields related to the properties of the default Saturation species (usually H2O).
pH_Estimate Fields related to the pH estimate
Charge Fields related to Charge
Transport Transport properties such as viscosity and thermal conductivity
DensityCorrections Additional density correction variables
HeatsOfCombustion The Heat of Combustion is the heat released (i.e. enthalpy change) if the stream components undergo complete combustion with oxygen to produce carbon dioxide gas and water.
Available from Build 139. (Replaces old Heating Values option.)
ValuesAtUserTandP Additional variables will be evaluated at the user defined temperature and pressure
SolutionImpurities Impurity flows, fractions and concentrations.
H2OProperties Properties of pure water and steam
WaterQuality Properties of water streams such as hardness, alkalinity and oxygen demand
The following variables shows the species model that is used to calculate the physical properties of the contents, such as density, heat capacity, etc.
SpModel.Reqd Inherit Upstream configuration will be used.
Standard All the variables are calculated using the Mass Weighted Mean of the species.
Species Model Use an alternative species model, such as 'Bayer3' or 'Potash'.
SpModel.Used Standard The Standard species model is being used.
Species Model An alternative species model is being used.
SpModelType Display This field displays the Species Model type (or Name) used.
SpModelIdNo Display This field displays a unique number generated when the Species Model is created.
ShowHeatingValues Tickbox Removed in Build 139. If ticked, then the calorific Heating Values of the material in the content will be displayed. From Build 139, refer to Heats Of Combustion.

Qualities

Lockup.Action Input / Display The user may select Modify Content. The 'Lockup' values are set on the 'DLockup' tab.
The field displays the actual state of the Lock Up function: If this has been enabled then this will display 'Lockup.Action(On)', otherwise it will display 'Lockup.Action'. Please see LockUp for more information.
Note: Lockup must first be enabled on the Plant Model - Qualities Tab and created upstream of the surge unit before the user may modify it here.
MatTrack.Action Input / Display The user may select Modify Content. The 'Tracking' values are set on the 'DTrack' tab.
The field displays the actual state of the Material Tracking function: If this has been enabled then this will display 'MatTrack.Action(On)', otherwise it will display 'MatTrack.Action'. Please see Material Tracking for more information.
Note: Material Tracking must first be configured on the Plant Model - Qualities Tab and created upstream of the surge unit before the user may modify it here.
SzDist.Action Input / Display The user may select Modify Content. The 'Size Distribution' values are set on the 'DSz' tab.
The field displays the actual state of the Size Distribution function: If this has been enabled then this will display 'SzDist.Action(On)', otherwise it will display 'SzDist.Action'. Please see Size Distribution (PSD) for more information.
Note: Size Distribution must first be created upstream of the surge unit before the user may modify it here.
SzSSA.Action Input / Display The user may select Modify Content. The 'SSA' values are set on the 'SSA' tab.
The field displays the actual state of the SSA function: If this has been enabled then this will display 'SzSSA.Action(On)', otherwise it will display 'SzSSA.Action'. Please see Specific Surface Area (SSA) for more information.
Note: SSA must first be created upstream of the surge unit before the user may modify it here.
Lockup.InUse Display Displays the state of the LockUp function: Yes or No.
MatTrack.InUse Display Displays the state of the Material Tracking function: Yes or No.
SzDist.InUse Display Displays the state of the Size Distribution (PSD) function: Yes or No.
SzSSA.InUse Display Displays the state of the Specific Surface Area (SSA) function: Yes or No.
Properties
This section is shown in the Dynamic Tank model but not in the Multi-Storage model.
Temperature / T Input / Display This displays the temperature of the material contents. The user may also change the temperature here.
Pressure / P Display The pressure of the material contents.
Level / Lvl Input / Display This displays the level of the material contents. The user may also set the level in the unit here.
HiLevelLimit / HiLmt Input The highest allowable level of the unit. If the solids and liquids level rises above this value, the unit will give a warning. The default value is 102%, so if the user does not change this value, it will never give a warning.
LoLevelLimit / LoLmt Input The lowest allowable level of the unit. If the solids and liquids level drops below this value, the unit will give a warning. The default value is 0%, so if the user does not change this value, it will never give a warning.
LevelHi / LvlHi Display This is True (1) if the unit level is above the HiLevelLimit and False (0) otherwise.
LevelLo / LvlLo Display This is True (1) if the unit level is below the LoLevelLimit and False (0) otherwise.
LimitAsStatus TickBox If this is disabled then the warning messages for High and Low limits will not be displayed.
Mass
TotalMass / Mt Calc The total mass of material in the unit.
SolidMass / SMt Calc The mass of solids in the unit.
LiquidMass / LMt Calc The mass of liquids in the unit.
VapourMass / VMt Calc The mass of vapours in the unit.
SlurryMass / SLMt Calc The mass of solids and liquids in the unit.
AqDissolvedMass / AqDissMt Calc The mass of dissolved aqueous species in the unit. This will be the sum of all aqueous species excluding water.
AqueousMass / AqMt Calc The mass of all aqueous species (including water) in the unit.
InitTtlMass / InitMt Calc The mass in the unit at the start of the solver run.
DeltaTtlMass / DeltaMt Calc The total change in mass in the unit from the start of the solver run.
Volume
TotalVol / Vt Calc The total volume of material in the unit.
SolidVol / SVt Calc The volume of solids in the unit.
LiquidVol / LVt Calc The volume of liquids in the unit.
VapourVol / VVt Calc The volume of vapours in the unit.
SlurryVol / SLVt Calc The volume of slurry (solids and liquids) in the unit.
Normal Volume
TotalNormVol / NVt Calc The total volume of material in the unit at normal conditions.
SolidNormVol / SNVt Calc The volume of solids in the unit at normal conditions.
LiquidNormVol / LNVt Calc The volume of liquids in the unit at normal conditions.
VapourNormVol / VNVt Calc The volume of vapours in the unit at normal conditions.
SlurryNormVol / SLNVt Calc The volume of slurry in the unit at normal conditions.
Density See the section on Density for further information.
Density / Rho Calc Calculated Density of the material
SolidDensity / SRho Calc Density of the solids phase
LiquidDensity / LRho Calc Density of the liquid phase
VapourDensity / VRho Calc Density of the vapour phase
SlurryDensity / SLRho Calc Density of the Slurry (Liquid and Solid phase)
SolidConc Calc The solids concentration at stream temperature.

Density Correction

Please see included properties - Density Correction.

Mass Fractions
SolidFrac / Sf Calc Solids mass fraction
LiquidFrac / Lf Calc Liquid mass fraction
VapourFrac / Vf Calc Vapour mass fraction
SlurryFrac / SLf Calc Available from Build 139.31388. Slurry (solids + liquids) mass fraction.
Slurry.SolidFrac / Slurry.Sf Calc Solids mass fraction on slurry basis (solids + liquids)
Slurry.LiquidFrac / Slurry.Lf Calc Liquid mass fraction on slurry basis (solids + liquids)
Volume Fractions
SolidVolFrac / Svf Calc Solids volume fraction
LiquidVolFrac / Lvf Calc Liquid volume fraction
VapourVolFrac / Vvf Calc Vapour volume fraction
SlurryVolFrac / SLvf Calc Available from Build 139.31388. Slurry (solids + liquids) volume fraction.
Slurry.SolidVolFrac / Slurry.Svf Calc Available from Build 139.31388. Solids volume fraction on slurry basis (solids + liquids)
Slurry.LiquidVolFrac / Slurry.Lvf Calc Available from Build 139.31388. Liquid volume fraction on slurry basis (solids + liquids)
Molar Fractions
MlSolidFrac / MlSf Calc Solids molar fraction
MlLiquidFrac / MlLf Calc Liquid molar fraction
MlVapourFrac / MlVf Calc Vapour molar fraction
MlSlurryFrac / MlSLf Calc Available from Build 139.31388. Slurry (solids + liquids) molar fraction.
MoleWt Calc The average molecular weight of all the species.
SolidMoleWt / SMoleWt Calc Available from Build 139. The average molecular weight of all solid species.
LiquidMoleWt / LMoleWt Calc Available from Build 139. The average molecular weight of all liquid species.
VapourMoleWt / VMoleWt Calc Available from Build 139. The average molecular weight of all vapour species.

Energy Values

Please see included properties - Energy.

Values at User Defined T and P

Please see included properties - Values at User Defined T and P.

Solubility Values

Please see included properties - Solubility.

Saturation Values

Please see included properties - Saturation .

Acidity (pH)

Please see included properties - Acidity

Charge

Please see included properties - Charge

Transport Properties

Please see included properties - Transport

Heating Values

Only available in Build 138 or earlier, please see included properties - Heating Values. For Build 139 or later, refer to Heats of Combustion.

Heats of Combustion

Only available in Build 139 or later, please see included properties - Heats of Combustion.

Solution Impurities

Please see included properties - Solution Impurities

H2O Properties

Please see included properties - H2O Properties

User Property Calculations

Users can define their own calculations (called User Property Calculations) in the Project Configuration (cfg File) which will be displayed on the Qi/Qo page. Refer to Calculation Configuration for more details.