Blend Control

From SysCAD Documentation
Jump to navigation Jump to search

NOTE: This feature is currently in BETA with limited release. Please contact us ([email protected]) if you are interested in using this model. This page is currently under development and details may change. Use with caution - we do not guarantee compatibility between different BETA versions.

Navigation: Main Page ➔ Process Control Models ➔ Blend Control Related Links: Multi-Storage


General Description

  • This unit operation is used to control the product grade from a Multi-Storage.
  • The main inputs to the model include specifying the Multi-Storage bin and product stream tags, the assay and assay count as well as the blend criteria.
  • The Blend Control model is used for dynamic simulation only.

Diagram

Blend Symbol.jpg

The diagram shows the default drawing of the Blend control unit.

Inputs and Outputs

There are no connections to this unit.

How to use the Blend Control

This screen dump shows the first tab from the Blend Control.

The variable "MultiStoreTag" is simply the Multi-Storage bin tag name which is going to be used with the controller. The stream tag is the Multi-Storage bin output stream tag name. This stream will be the blended product.

Blend Access.jpg

Data Sections

The default sections and variable names are described in detail in the following tables.

  1. The first tab contains general information relating to the unit.
  2. The second "ASSY" tab contains the settings for controlling the number of assays as well as the type of species per assay.
  3. The next "BC" tab allows you to select the blend method, number of criteria and tank fractional limits etc.
  4. If using the 'Auto' blend method, the "Crit" tab will appear and contains settings for the criteria requirements.

Unit Type: BlendCon - The first tab page in the access window will have this name.

Tag / Symbol

Input / Calc

Description/Calculated Variables / Options

Common Data on First Tab Page

On Tick Box Enables or disables the Blend Control.
MultiStoreTag Input Input for the multi-storage bin tag name.
StreamTag Input Multi-storage bin output stream tag.
CalculateAlways Tick Box Calculate the blend flow rates continually.
ConditionsOff Tick Box
TrackErrors Tick Box Allow the software to track errors relating to the blend solution
TrackLowMassErrors Tick Box Allow the software to track errors relating to low bin levels in the multi storage bins vs blend requirements.
TrackNotes Tick Box Allow the software to record notes relating to solver outcomes
TrackSetData Tick Box Allow the software to record changes to set data
State Display Determines the state of the blend controller
Msg_1 Display Message display

Adding this Model to a Project

Add to Configuration File

Sort either by DLL or Group:

  DLL:
Control2.dll
Units/Links Control 2: Blend
or Group:
General
Units/Links Control 2: Blend

See Model Selection for more information on adding models to the configuration file.


Insert into Project Flowsheet

  Insert Unit Control 2 Blend

See Insert Unit for general information on inserting units.