Search results

Jump to navigation Jump to search
  • Get Tag List (category Models) (section Get Tag List Format)
    easiest way to create the Get Tag List is by using MS Excel. The Get Tag List format and example is given above. Once the Get Tag List is created, save it as
    6 KB (605 words) - 16:38, 2 August 2023
  • Set Tag List (category Models) (section Set Tag List Format)
    The Get Tag List model also supports optional multiple columns so if the current column number for this is changed at the same time, the Get Tag List
    9 KB (817 words) - 19:09, 2 August 2023
  • ; 1) [[Set Tag List]] Model is used to Set the user defined data ; 2) [[Get Tag List]] Model is used to report the required value (with GetAtEnd option
    19 KB (907 words) - 02:09, 21 February 2024
  • lines within their set tag list by starting the line with a semi-colon (;), similar to PGMs. This also applies to Get Tag List Model. The Environmental Heat
    42 KB (6,030 words) - 18:10, 2 August 2023
  • version released in January 2009. Implemented new Get Tag List Model. New Alumina 3 Bayer Species Model. (Note that if you were using earlier Build 126 versions
    18 KB (2,754 words) - 03:55, 11 September 2023
  • Orderby [Graphic] [Parent.Tag] [Index], Groupby [Parent.Tag] [Tag] BoldHeading:1, Clear: On) To create a list for all the PIDs: SysCAD_TagSelect(PID, V,50,1000
    29 KB (2,682 words) - 14:42, 3 April 2024
  • Model Procedures (category Sub-Models)
    use the "Copy Tag for PGM" option to Copy the Tag from Access Window Right click popup list Use Copy Tag (without the model name) when a tag is being concatenated
    20 KB (1,014 words) - 01:44, 6 September 2023
  • when mouse hovers over the drop list field includes 'Underlying tag is a String type' in the description. When making the droplist selection from a PGM
    34 KB (1,045 words) - 23:50, 5 September 2023
  • General Controller (category Models) (section Model Theory)
    and PGMs Set Tag Controller - the user may carry out the simple ratio control and set multiple tags using the the Set Tag Controller model. The diagram
    20 KB (1,211 words) - 03:31, 5 April 2024
  • a simple list of all models. Flange Flows is a list of all flanges (the connection flange objects between pipes and models). Tears is a list of all Solver
    23 KB (1,074 words) - 14:19, 2 August 2023
  • Variable Tag: some report type (e.g.: Tag List report) requires the Full Variable Tag, please use Copy Full Tag to copy the tag. Primary tag: When a full
    24 KB (2,037 words) - 17:02, 2 August 2023
  • and choose the Copy Graphics, Tag List to Clipboard option, then paste them into MS Excel. To obtain an equipment list for a selected graphics page, from
    11 KB (986 words) - 03:35, 5 April 2024
  • stricter model tag naming rules by not allowing four more symbols in tag names (\ ' " and ;). Give error message at project load if any models contain illegal
    33 KB (5,180 words) - 11:24, 14 February 2024
  • Build139 or later, user can get the used/unused species list directly from Plant Model - Species tab. How to generate a list of Species with Flow, useful
    7 KB (589 words) - 03:35, 7 February 2023
  • Models (category Models) (section General Models)
    implemented as a Species Properties Model but as a unit model for use at appropriate locations in a plant model. These models use OLI Systems leading Electrolyte
    62 KB (2,065 words) - 03:33, 23 April 2024
  • Vapour Liquid Equilibrium (VLE) (category Sub-Models) (section Model Theory)
    vapour and liquid species in the model or stream. The VLE sub-model is used in a number of unit models. Different models may have options to specify some
    22 KB (1,593 words) - 00:17, 13 December 2023
  • Exec(Criteria_Tag, false, false) ; find total number of SpeciesChanges SpciesChangeCount = SpeciesChanges.GetLen() ; get all species change flows flow_tag = Concatenate("
    7 KB (632 words) - 06:27, 22 February 2024
  • Feeder-Cross Page Connector (category Models) (section Model Theory)
    first section, Model. Model determines which species model the feeder uses. The options available to the user will depend on the species model used by the
    47 KB (2,683 words) - 09:04, 2 February 2024
  • allows the user to set some solver related tags as well as display the current status for the SysCAD application. Tag groups on this tab include: Project Solver
    21 KB (106 words) - 10:13, 3 August 2023
  • Data dialog box will bring up the following pop up list: For most of the options on the pop up list, they are simply an alternate method to access the
    15 KB (1,320 words) - 11:47, 3 May 2024
  • Analysis - scenarios, tag list document, command script and COM automation. Topics covered in this document include: Using sub models in the unit operation
    8 KB (922 words) - 01:42, 10 May 2024
  • variable, user may get "Unknown tag "GM.IOs.[P_002].Splt.H2O(l) (%)'", this is because the [] function expects a full tag instead of partial tag. Please see troubleshooting
    11 KB (1,465 words) - 04:14, 13 May 2024
  • of a changed tag. This is relevant to the Get Tag List, Set Tag List, Plant Model Set Tag List, Events, Profile and Queue Profile models, as well as the
    3 KB (9 words) - 10:53, 27 April 2021
  • Marshal IO tag list must be made directly in the tag list file, there is no user interface in SysCAD or SysCAD Marshal to manage the tag list. When adjustment
    33 KB (5,359 words) - 10:13, 1 February 2024
  • SysCAD_SetTagList(ReportName, Tag Location (either H or V), Search Length). These parameters are explained in Basic Format of a simple Get Tag Report. Some
    11 KB (1,168 words) - 18:42, 2 August 2023
  • Profile (category Models) (section Adding this Model to a Project)
    Navigation: Models ➔ Control 2 Models ➔ Profile Controller The Profiler model is only used in Dynamic projects. It allows users to vary input parameters
    17 KB (1,330 words) - 05:32, 5 September 2023
  • mathematical model is attached to some selected graphics from the DXF drawing. The unit model's mathematical model and its graphics are linked by a tag name:
    13 KB (1,068 words) - 14:18, 2 August 2023
  • Controller or Model Procedures; Tags may also be set from any of the following units: Set Tag List Model, Profile Model, Events Model, Queue Model, Noise Model
    7 KB (855 words) - 02:06, 15 June 2021
  • Tag List Step 3: Create 2 csv files, one containing the User Defined values for the Set Tag List and another containing the results for the Get Tag List.
    19 KB (2,641 words) - 03:13, 7 February 2024
  • right click on the tag and select "Open Find Results" menu option (or press F8) to get a list of values for this tag in all unit models of the same type
    114 KB (16,094 words) - 02:05, 24 April 2024
  • PGM Include Files, Get Tag List, Set Tag List, Plant Model Set Tag List, Task Model, Events Model, Profile Model, Queue Profile Model, Command Scripts A
    3 KB (342 words) - 23:57, 24 March 2021
  • Au(s) (oz/d)" print ("Gold in product", end=" ") print (Tags.TagValue(goldFlow)) ## Get a tag value Solver = Prj.Solver ProBal = Solver.ProBal ProBal.Start()
    11 KB (1,558 words) - 18:42, 2 August 2023
  • Class (section ClassList)
    class name to the unit model tag through use of UnitTag = ClassTag() within the class definition, then we can use the unit tag name as the class instance
    46 KB (4,504 words) - 01:29, 12 March 2024
  • you can use any of those that you see in the list when you insert a unit model, or just "*Default*" to get the default symbol. The final parameters are
    6 KB (869 words) - 18:56, 1 September 2022
  • Noise Controller (category Models) (section Model Theory)
    }[/math] = Standard Deviation For all methods, the tag PlantModel.RandomSeedAtStart (set on the Plant Model - FlwSolve page) affects the repeatability of the
    13 KB (416 words) - 13:50, 1 February 2024
  • Queue Profile (category Models) (section Adding this Model to a Project)
    SysCAD finds a blank column or an invalid tag, all remaining tags are ignored. Queue Profiles do not support string tags. The columns in the profile should contain
    7 KB (340 words) - 01:37, 6 September 2023
  • the SysCAD Excel Get Tag Reports, the tag "Graphic" may be used to report the name of the graphics window that the unit is on. See List Graphics Symbols
    16 KB (2,028 words) - 03:06, 5 April 2024
  • stage. If the Set Tag List or General Controller appear to be setting tags too late, then consider using the Set Tag List in the Plant Model - Project or methods
    4 KB (570 words) - 03:41, 27 March 2024
  • Makeup Source (category Models) (section Model)
    first section, Model. Model determines which species model the feeder uses. The options available to the user will depend on the species model used by the
    21 KB (899 words) - 03:34, 5 April 2024
  • Configuration File Sort either by DLL or Group: See Model Selection for more information on adding models to the configuration file. Insert into Project Flowsheet
    18 KB (1,286 words) - 09:26, 2 February 2024
  • Reactor (Gibbs FEM) (category Models) (section Model Theory)
    FEM model is used in an overall plant model, the user has no direct control over which species are present in the feed, and consequently the model may
    73 KB (3,653 words) - 05:20, 7 February 2024
  • example 2 on how to set up user calculations. The model is not currently sensitive to pH or temperature. The model assumes that the pH and temperature are correct
    47 KB (3,928 words) - 05:12, 21 February 2024
  • PID Controller (category Models) (section Model Theory)
    iteration is treated as a "one second time increment". The PID Output tag and the Measured tag, will have coloured triangles shown in the access window of those
    34 KB (2,509 words) - 03:27, 5 April 2024
  • Events (category Models) (section Adding this Model to a Project)
    sets SysCAD tags at regular intervals using a profile that is read in from a CSV file. The Scheduled Events model will set a single SysCAD tag to a required
    10 KB (481 words) - 13:51, 1 February 2024
  • Navigation: Models ➔ Control 2 Models ➔ Scheduled Events This model is used in Dynamic Simulation only. This unit is similar to the Downtime model and the
    11 KB (379 words) - 01:44, 6 September 2023
  • inlet stream has a quality model, all the outlet streams will have the same quality models. Unless in some cases where a unit model can be configured to prevent
    10 KB (1,566 words) - 01:36, 6 September 2023
  • species model in the configuration file as shown below. It is then possible to select the Bayer model (either Bayer3 or a client-specific Bayer model). On
    28 KB (784 words) - 14:07, 14 March 2024
  • contain a number of documents, these may include: Model files - ModelData.db3, stores the project model data. Graphics files - xxxx.DXF and xxxx.scg file
    13 KB (1,190 words) - 03:38, 5 April 2024
  • imbalance in the model, user will be given a warning, to prevent this, make sure the steam supply is auto adjusted via General controller / Set Tag Controller
    49 KB (3,135 words) - 01:11, 7 February 2024
  • Signal Waveform (category Models) (section Model Theory)
    Navigation: Models ➔ Control 2 Models ➔ Signal Waveform Controller The Signal Waveform Controller model is used in Dynamic projects. It allows input of
    19 KB (1,298 words) - 05:23, 7 February 2024
View (previous 50 | ) (20 | 50 | 100 | 250 | 500)