Solver Setting - PB

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ ProBal

SS Only Dynamic Mode Only
FS_Solver ProBal Dynamic Method Scenario Spills Vents SS Monitor SS Finder Convergence GlobalTear Tears TearTags Tolerances Analysis Changes

This tab will only be available in a Steady State (ProBal) project.

This tab page lists some of the configuration options as per the Solver Set up for Steady State Projects command.

Tag (Long/Short)

Input / Calc

Description

PB...
ProBal Solver Settings
Solver Start Actions
SetTimeToZero Tickbox Sets the time to zero at the start of the run.
RestartHistorian Tickbox Restarts the Historian at the start of the run.
InActiveNodes Ignore Inactive units will be ignored.
Reset Inactive units will be reset.
Options
LowQmFracOther Input Used when calculating the pressure used when mixing streams and there is no overriding pressure set or active OperatingP. The AutoDetect method as described in OperatingP is used and this determines the amount required for any stream to contribute to the total flow when calculating the mixture pressure. For example, if the total feed to the unit is 10 kg/s, and this field is set to 1%. Then any feed streams with less than 0.1 kg/s will be ignored in the pressure calculations.
ResultsValid Display A value of 1 indicates that the results are valid, while a value of 0 indicates that the results are invalid.