Solver Setting - PB
Jump to navigation
Jump to search
Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ ProBal
| SS Only | Dynamic Mode Only | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FS_Solver | ProBal | Dynamic | Method | Scenario | Spills | Vents | SS Monitor | SS Finder | Convergence | GlobalTear | Tears | TearTags | Tolerances | Analysis | Changes |
This tab will only be available in a Steady State (ProBal) project.
This tab page lists some of the configuration options as per the Solver Set up for Steady State Projects command.
|
Tag (Long/Short) |
Input / Calc |
Description |
| PB... | ||
| ProBal Solver Settings | ||
| Solver Start Actions | ||
| SetTimeToZero | Tickbox | Sets the time to zero at the start of the run. |
| RestartHistorian | Tickbox | Restarts the Historian at the start of the run. |
| InActiveNodes | Ignore | Inactive units will be ignored. |
| Reset | Inactive units will be reset. | |
| Options | ||
| LowQmFracOther | Input | Used when calculating the pressure used when mixing streams and there is no overriding pressure set or active OperatingP. The AutoDetect method as described in OperatingP is used and this determines the amount required for any stream to contribute to the total flow when calculating the mixture pressure. For example, if the total feed to the unit is 10 kg/s, and this field is set to 1%. Then any feed streams with less than 0.1 kg/s will be ignored in the pressure calculations. |
| ResultsValid | Display | A value of 1 indicates that the results are valid, while a value of 0 indicates that the results are invalid. |