Solver Setting - Scenario
Jump to navigation
Jump to search
Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ Scenario
SS Only | Dynamic Mode Only | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FS_Solver | ProBal | Dynamic | Method | Scenario | Spills | Vents | SS Monitor | SS Finder | Convergence | GlobalTear | Tears | TearTags | Tolerances | Analysis | Changes |
Tag (Long/Short) |
Input / Calc |
Description |
Scenario... | ||
Specification | ||
Type | Manual | User manually press the Stop button to end the dynamic simulation run. |
Duration | User specifies a duration and SysCAD will stop the simulation when the duration period is reached. | |
StopTime | User specifies a Stop time and SysCAD will stop the simulation when the time counter has been reached. | |
Steps | User specifies the required number of steps and and SysCAD will stop the simulation when the step count is reached. | |
SteadyState | For this type of scenario, user must first set up some checking criteria on the Solver Setting - SS Monitor Tab, the user defined criteria will be used to stop the scenario when the conditions are met. | |
DurationReqd.Fmt | Input | Only visible with Type set to Duration. User can set the duration in a time format: Day:Hour:Minute:Seconds. For example: duration of 2 days and 1 hour can be set as: 2:01:00:00. Note that if this field is changed, after pressing the OK button the DurationReqd field is adjusted accordingly. |
DurationReqd | Input | Only visible with Type set to Duration. User can set the duration in terms of a time engineering unit. For example: duration of 2 days and 1 hour can be set as: 2.04 d OR 49 h. Note that if this field is changed, after pressing the OK button the DurationReqd.Fmt field is adjusted accordingly. |
StopTimeReqd.Fmt | Input | Only visible with Type set to StopTime. User can set the stop time in a time format: Day:Hour:Minute:Seconds. This works in conjunction with the Start Time, which can be found under Scenario.Start. For Example, if StopTimeRqd.Fmt is set at 0:00:20:00, and StartAt.Fmt is set at 0:00:10:00 with SetTime Ticked, the simulation will only run for 10 minutes and it will stop. Note that if this field is changed, after pressing the OK button the StopTimeReqd field is adjusted accordingly. |
StopTimeReqd | Input | Only visible with Type set to StopTime. User can set the stop time in terms of a time engineering unit. This works in conjunction with the Start Time, which can be found under Scenario.Start. For Example, if StopTimeRqd is set at 1200s, and StartAt is set at 600s with SetTime Ticked, the simulation will only run for 600s and it will stop. Note that if this field is changed, after pressing the OK button the StopTimeReqd.Fmt field is adjusted accordingly. |
StepCountReqd | Input | Only visible with Type set to Steps. The required number of steps to run before stopping. |
StopTime.Fmt | Display | Displays the StopTime in a time format. |
StopTime | Display | Displays the StopTime. |
ScnTime.Fmt | Display | Displays the current scenario time in a time format. |
ScnTime | Display | Displays the current scenario time. |
ScnTimeEnd.Fmt | Display | Displays the Scenario Ending time in a time format. |
ScnTimeEnd | Display | Displays the Scenario Ending time |
Solver Start Behaviour | ||
IfManualScn | Display | Only visible when Type is set to Manual.
|
The following two fields are visible when Type is set to Duration, StopTime, Steps or SteadyState. | ||
IfScnBusy | Display |
|
IfScnComplete | Ignore | If the simulation scenario has been completed, SysCAD will ignore the run command. NB If the scenario has completed and you try to restart SysCAD it will report "Scenario Complete - Restart Ignored" in the message window. To restart SysCAD, you must go to the Cmds tab and press the "Restart Scenario" button. |
ReStart | SysCAD will restart the scenario. | |
Start... | ||
Startup Options | ||
SetTime | Tickbox | Selecting this option will set the Start time specified in the following fields. |
StartAt.Fmt | Input | Allows the user to set a starting time in the format of Day:hour:Minute:seconds. This field will be used to determine the scenario run time if the StopTime Type has been selected. Note that if this field is changed, after pressing the OK button the StartAt field is adjusted accordingly. NOTE: use "StartAt" (next tag, maybe hidden) to set the start time from pgm or csv files. |
StartAt | Input | Allows the user to set a starting time. This field will be used to determine the scenario run time if the StopTime Type has been selected. Note that if this field is changed, after pressing the OK button the StartAt.Fmt field is adjusted accordingly. NOTE: use this tag to set the start time from pgm or csv files. See also Useful PGM code for Dynamic Projects. |
RestartHistorian | Tickbox | Selecting this will Restart the Historian when scenario is started. |
SetHistorianTagList | Tickbox | Selecting this will Set the Historian Tag List if used when scenario is started. |
RestartArchive | Tickbox | Selecting this will Restart the Archiver if used when scenario is started. Note that if this is enabled, it will override whatever setting the Clear parameter has been set to in the sac file. |
InActiveNodes | Ignore | Ignores all inactive models. (All inactive models will retain all the contents and conditions, care must be taken when analysing the results, should flag these model as inactive in the report, or not report them) |
Empty | Empties all inactive models. | |
Preset | Presets all inactive models according to their preset image. Make sure preset data have been defined. | |
Startup Reset Actions (These may also be set from the FS_Solver page of the Solver Access window) | ||
Process | Tickbox | This will empty all pipes and flow values when the run begins. |
Control | Tickbox | This will reset all controllers back to 'Base' state, i.e. the same state as when the controller is first inserted into the project. This is mainly relevant for PID controllers. |
Statistics | TickBox | Selecting this will Reset the Statistical blocks when scenario is started. |
EventsProfiles | TickBox | This will reset all Event and Profiles back to start time. |
Empty | Tickbox | This Empties all containers with surge, e.g. Tanks. |
Preset | Tickbox | This resets all tanks that have the 'Preset.On' button ticked and have Preset data. |
End... | ||
Completion Options | ||
Action | Stop | SysCAD will be stopped when scenario is completed. |
Idle | SysCAD will be placed in idle state when scenario is completed. | |
Results | ||
State | Display | Displays the state of the scenario run:
|
Reset | Reset Scenario Button | Resets the scenario |
Elapsed Time & Progress | ||
Progress | Display | Displays the simulation progress as a percentage of completion. |
Elapsed.Time | Display | Displays the current elapsed time. |
Elapsed.EstToGo | Display | Displays the estimated time till completion of the scenario. |