Solver Setting - Method
Jump to navigation
Jump to search
Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ Integration
SS Only | Dynamic Mode Only | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FS_Solver | ProBal | Dynamic | Method | Scenario | Spills | Vents | SS Monitor | SS Finder | Convergence | GlobalTear | Tears | TearTags | Tolerances | Analysis | Changes |
This page is for Build 139 or later. For Build 138 or earlier, please see Solver Setting - Integration or Solver Setting - Network.
Tag (Long/Short) |
Input / Calc |
Description |
Dynamic Solver Settings | ||
RealTime.SyncClock | Tickbox | |
RealTime.On | Tickbox | SysCAD will solve the model at a speed relative to the time on your PC. If the RealTimeMultiplier is set to 1 (100%), then it will take 1 second of running time to simulate 1 second of real time. |
RealTime.Multiplier | Input | Multiplier of time when using the RealTime option. If the RealTimeMulitplier is set to 2 (200%), then it will take 1 second of running time to simulate 2 seconds of real time. |
StepSize | Input | The size (time) of each step. A higher value results in a faster relative speed, but generally a less accurate solution. The maximum step size that can be used is dependent on the dynamics of process (relative flow rates, volumes of units, timing of events, etc.). A single step can have multiple iterations to solve the flowsheet and associated controls, similar to solving a steady state project. The maximum number of iterations per step is set on the Tears tab . |
StepSize.Min | Input | Minimum step size. |
StepSize.Max | Input | Maximum step size. |
Integration | ||
Method | Input | The method used for the dynamic simulation can be changed here.
|
DerivEstInc | Input | |
Link Convergence | ||
Link.RelTol | Input | The relative tolerance used when determining the estimated flows in a piping network. |
Link.AbsTol | Input | The absolute tolerance used when determining the estimated flows in a piping network. |
Network Convergence | ||
Network.DeRating | Input | |
Network.MaxResRatio | Input | |
Network.CnvCount | Input | |
Network.ResRunAvgStart | Input | |
Network.ResRunAvgCount | Input | |
Network.UDFCnvCount | Input | |
Network.FastConverge | Tickbox | |
Flow Calculations | ||
NetFlow.Vapour | Allow | |
Force | ||
Block | ||
NetFlow.Liquid | Allow | |
Force | ||
Block | ||
Mass Flow Differences | ||
ShowQmDiffAs | Off | |
Note | ||
Warning | ||
Error | ||
QmMatchRel | Input | |
QmMatchAbs | Input | |
Options | ||
KFactMult | Input |