Solver Setting - Changes

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ Menu Commands ➔ View ➔ Solver Settings ➔ Solver Setting - Changes

SS Only Dynamic Mode Only
FS_Solver ProBal Dynamic Method Scenario Spills Vents SS Monitor SS Finder Convergence GlobalTear Tears TearTags Tolerances Analysis Changes

Reworked for Build 139.36061.

Changes

Change Monitor is similar to Analysis in that it provides a mechanism to monitor selected values and changes in the solver. It can provide a useful output of changes while troubleshooting or trying to understand problems in solver convergence. Unlike the Analysis feature, this simply outputs all the selected changes to output log files for each iteration.

Tag (Long/Short) Input/Calc Description
Change Monitor
On Tickbox By default, Monitor.On is always switched off when a project is loaded (the setting is intentionally not saved). When the user requires this feature, simply turn it on, then run the project to monitor changes in the project.
LogMessages Tickbox Output some information messages while collecting Changes to the Messages tab of Message Window.
Items to Track
Track.Inputs Tickbox Stream inputs to Pipes and Unit models.
Track.Outputs Tickbox Stream outputs to Pipes and Unit models.
Track.Tears Tickbox Stream Tears.
Track.TagRefs Tickbox Controller cross reference tags.
Track.Conditions Tickbox Condition messages for Pipes and Unit models.
Options for Inputs & Outputs
Include.MassPhase Tickbox Include stream phase massflow tags SQm, LQm and VQm.
Include.Energy Tickbox Include stream tags totHf and T.
Include.Species Tickbox Include individual species mass flows.
Include.Properties Tickbox Include stream tags P, SatT@P and Rho.
Include.Qualities Tickbox Currently only PSD quality is included (if in use in project).
Filter
Select Errors Only report errors.
Changes Only report changes larger than specified ChangeBy.
All Report Changes and Errors.
ChangeBy Input The relative change for reporting Changes. Only shown if Filter selection is Changes or All.
Report Files
Report.Location Project.Log Change monitor files placed in project LogOutputs folder.
Temp.Folder Change monitor files placed in user Temp folder.
Report.FileID Input Prefix part of filename generated.
Report.Delete Button Delete change monitor files found.
Report.Filename Display Full filename of last change monitor file generated.
Report.Open Button Open last change monitor file in a text editor.