NOTE: This feature is distributed with SysCAD but is currently in BETA. Please contact us ([email protected]) if you run into any issues using this model. This page is currently under development and details may change. Use with caution - we do not guarantee compatibility between different BETA versions.

Navigation: Models ➔ TCE Models ➔ ChemApp ➔ ChemApp Tank

ChemApp
Overview
ChemApp
Database Utility
ChemApp
Model Configuration
ChemApp
Direct Calc
ChemApp
Side Calc
ChemApp
Reactor
ChemApp
Feeder
ChemApp
Tank (Dynamic)

Latest SysCAD Version: 25 October 2024 - SysCAD 9.3 Build 139.36522

Related Links: ChemApp SysCAD Project Workflow


Released as a BETA version in Build 139.36061.

General Description

The ChemApp Tank model is used in Dynamic mode to emulate a perfectly mixed tank with surge. The model allows the user to 'call' the ChemApp solver to determine the state of the tank content.

The results can be applied to the tank content or just performed as a side calculation (similar to use of the ChemApp Side Calc Model).

Notes

  1. The user MUST have added and configured a ChemApp Model Configuration unit in the SysCAD project before this unit can function.
  2. The user MUST have installed a version of ChemApp on their computer to make use of the ChemApp functionality in SysCAD. Please see gtt-technologies.de for more information.

Inputs and Outputs

Label Required /
Optional
Input /
Output
Number of Connections Description
Min Max
Feed 1 Required Input 1 10 The feed to the Tank.
Overflow Required Output 1 1 Tank overflow stream.
Product Optional Output 0 5 Outlet stream/s from the Tank.
Vent Optional Output 0 1 Vent Stream (Vapour Only).

The ChemApp Tank can be incorporated into a SysCAD flowsheet, it can be connected with SysCAD inlet and outlet streams.

Model Theory

The ChemApp Tank Model uses the ChemApp algorithms and data to determine the status of the solution.

Mapping of the SysCAD to ChemApp streams is done via Species Mapping.

The ChemApp Tank can be incorporated into a SysCAD flowsheet, it can be connected with SysCAD inlet and outlet streams.

  1. User connects the ChemApp Tank with SysCAD input streams,
  2. The SysCAD feed stream(s) using SysCAD species is converted into ChemApp "Input" using ChemApp Species. The species mapping is defined in the corresponding ChemApp Model Configuration unit model.
  3. The ChemApp Tank calls the ChemApp algorithms to determine the status of the mixture using the converted ChemApp "input" data.
  4. The ChemApp results are displayed in the "output" tab using ChemApp species.
    • If the ChemApp Tank is in Side Calc mode, the results are NOT converted into SysCAD species. (SysCAD stream outlet = sum of SysCAD inlet streams, no change will occur)
    • If the ChemApp Tank is in Reactor mode, then the results are converted back into SysCAD species. Please see Species Mapping for more information.

NOTES:

  • The Input, Output and Diff tab pages are displayed using ChemApp species, as defined in the database (.cst or .dat) specified in the corresponding ChemApp Model Configuration unit model.
  • The species used in the SysCAD project are shown on the optional Sp pages, shown as part of the QFeed, QBypass, QUnmapped, QRxnProdBypass and QProd pages.
  • The calculations performed are similar to using ChemApp directly, except the contents of the SysCAD stream are mapped to equivalent ChemApp species using the settings defined in the ChemApp Model Configuration unit model.


Workflow

The suggested workflow for configuring the model is:

  1. Make sure the project contains at least one of the ChemApp Model Configuration model, and the model is loaded with the correct ChemApp database you would like to use for the ChemApp Tank model.
  2. On the ChemAppTank tab page, configure the model - methods, pressures, etc.
  3. On the TCE tab page, select the correct ChemModel (to match step 1) (Note: In older builds, this selection was made on the ChemAppTank tab page).
  4. Select other TCE options (Bypass, CFE, etc.)
  5. Perform an equilibrium calculation by pressing Solve in SysCAD.
  6. The Results are displayed in the CHEMAPPResults and Output tabs.
  7. Check and fix any species mapping issues. (ChemApp resulting species may change if the operating conditions change, so it is likely a change of temperature or feed composition will result in different ChemApp species.)

Data Sections

  1. ChemAppTank tab - This first tab allows the user to set some general options including the volume of the tank.
  2. Outlets tab - This tab allows user to configure the optional Product streams from the tank.
  3. TCE tab - This tab allows the user to choose the corresponding ChemApp Model Configuration unit and set other TCE options including the choice of model (Reactor or Side Calc).
  4. VLE - Optional tab, only visible if Model = Reactor and the UseSysCADVLE/VLE.On option is enabled on the TCE tab page.
  5. CFE - Optional tab, only visible if the UseCFE option is enabled on the TCE tab page.
  6. Bypass - Optional tab, only visible if the WithBypass option is enabled on the TCE tab page.
  7. RxnBypass - Optional tab, only visible if the WithBypass option is enabled on the TCE tab page.
  8. ChemAppResults tab - This tab displays the key results of the calculations.
  9. Input tab - This tab displays a summary of the mapped Input stream as ChemApp species.
  10. Output tab - This tab displays the Output stream results including the amounts of each ChemApp species present in the final mixture.
  11. Diff tab - Optional tab, only visible if the ShowRxnDiff option is enabled on the TCE tab page. This tab displays the amounts of each species which are formed or reacted as part of the calculations.
  12. ElemBal tab - This tab displays an elemental balance between the Input and Output streams.
  13. PhDeport tab - Optional tab, only visible if the PhaseElemDeportment option is enabled on the TCE tab page. This tab shows the movement of elements for the Solid, Liquid and Gas phases.
  14. IPhDeport tab - Optional tab, only visible if the IPhaseElemDeportment option is enabled on the TCE tab page. This tab shows the movement of elements for the individual ChemApp phases.
  15. UnitTag.ParamSweep tab - Optional tab, only visible if the ShowPlotter option is enabled on the TCE tab page. This tab allows the user to generate sets of data.
  16. SpForPlot tab - Optional tab, only visible if the SelectSp option is enabled on the UnitTag.ParamSweep tab. This tab allows the user to select which species to be reported in the sets of data to be generated.
  17. QUnmapped - Optional tab, only visible if ShowQUnmapped is enabled on the TCE tab page.
  18. QRxnUnmapped - Optional tab, only visible if ShowQRxnUnmapped is enabled on the TCE tab page.
  19. QBypass - Optional tab, only visible if ShowQBypass is enabled on the TCE tab page.
  20. QRxnBypass - Optional tab, only visible if ShowQRxnBypass is enabled on the TCE tab page.
  21. QFeed - Optional tab, only visible if ShowQFeed is enabled on the first tab page.
  22. Content tab - contains data on the material in the tank.
  23. Preset tab - Optional tab, only visible if UsePreset option is enabled on the first tab page. Allows user to define the Preset composition.
  24. QOF - Optional tab, only visible if ShowQF is enabled on the first tab page.
  25. QOutlet - Optional tab, only visible if ShowQOutlet is enabled on the first tab page.
  26. Preset tab - Optional tab, only visible if UsePreset option is enabled on the first tab page. Allows user to define the Preset composition.
  27. Info tab - contains general settings for the unit and allows the user to include documentation about the unit and create Hyperlinks to external documents.
  28. Links tab, contains a summary table for all the input and output streams.
  29. Audit tab - contains summary information required for Mass and Energy balance. See Model Examples for enthalpy calculation Examples.

ChemAppTank tab page

Unit Type: ChemAppTank - The first tab page in the access window will have this name.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.
If this field is blank, then SysCAD will display the UnitType or SubClass.
Requirements
Capacity.Volume Input The volume of the tank. Visible in dynamic mode only.
OperatingP - NOTE: this pressure is applied to the (combined) feed, before sub-models (if any).
Method AutoDetect If there are any liquids AND no vapours present in the feed, outlet streams will take the highest pressure of the feeds. Else (e.g. some vapours present) outlet streams will take the lowest pressure of the feeds.
LowestFeed Outlet streams will take the lowest pressure of the feeds.
HighestFeed Outlet streams will take the highest pressure of the feeds.
Atmospheric Outlet streams will be at Atmospheric Pressure. The atmospheric pressure is calculated by SysCAD based on the user defined elevation (default elevation is at sea level = 101.325 kPa). The elevation can be changed on the Environment tab page of the Plant Model.
RequiredP Outlet streams will be at the user specified pressure.
IgnoreLowMassFlow / IgnoreLowQm Tick Box This option is only visible if the AutoDetect, LowestFeed or HighestFeed methods are chosen. When calculating the outlet pressure and temperature of the tank, SysCAD will ignore the low flow feed streams should this option be selected. The low flow limit is set in the field below.
LowMassFlowFrac / LowQmFrac Input This field is only visible if the IgnoreLowQm option is selected. This is the amount any stream contributes to the total flow. For example, if the total feed to the tank is 10 kg/s, and this field is set to 1%. Then any feed streams with less than 0.1 kg/s will be ignored in the pressure calculations.
PressureReqd / P_Reqd Input This field is only visible if the RequiredP method is chosen. This is user specified pressure.
Result Calc The actual pressure used for the sum of the feeds which will also be the outlet pressure (unless further model options change the pressure).
PresetData...
UsePreset Tickbox If ticked, will allow user to set temperature, level and composition of the tank at startup. The composition can be set on the Preset tab page.
Temperature / T Input Only visible if UsePreset has been enabled. The temperature of the contents of the tank at startup.
Pressure / P Input Only visible if UsePreset has been enabled. The pressure of the contents of the tank at startup.
Level Input Only visible if UsePreset has been enabled. The level of the tank at startup.
Options
TrackOverflow Tickbox If ticked, will enable warnings if material is sent to overflow stream.
ShowQFeed Tickbox Allows the user to view the QFeed and associated tab pages, showing the properties of the combined feed stream. See Material Flow Section. This will be prior to any sub-model actions, mixing with the tank content or ChemApp calculations.
ShowQOF Tickbox Allows the user to view the QOF and associated tab pages, showing the properties of the overflow stream. See Material Flow Section. This will be the perfectly mixed tank contents after ChemApp calculations.
ShowQOutlet Tickbox Allows the user to view the QOutlet and associated tab pages, showing the properties of the outlet stream. See Material Flow Section. This will be the perfectly mixed tank contents after ChemApp calculations with the filter applied.
Results Summary (Tank)
Temperature / T Calc The current temperature of the contents of the tank.
Density / Rho Calc The current density of the contents of the tank.
TotalVol / Vt Calc The current volume of the contents of the tank.
Level / Lvl Calc The current level of the contents of the tank.
SolidFrac / Sf Calc The current fraction of solids in the contents of the tank.
TotalMass / Mt Calc The current mass of the contents of the tank.
InitTtlMass / InitMt Calc The mass of the contents of the tank at the start of the solver run.
DeltaTtlMass / DeltaMt Calc The total change in mass of the contents of the tank since the start of the solver run (TotalMass - InitTtlMass).
MassRateOfChange / QmAcc Calc The rate of accumulation of mass in the content of the tank.
MtAcc Calc The total change of mass over the time step.
Results Summary (Outlet Streams)
(The following group of tags are shown for each Product outlet stream connected to the Tank)
XXX Outlet Stream
XXX ...
CapControl.MassFlowReqd / QmReqd Calc Outlet mass flowrate required based on capacity control requirements (only relevant if downstream pipe is in push mode).
Pull.MassFlowReqd / QmReqd Calc Outlet mass flowrate required based on downstream pull requirements (only relevant if downstream pipe is in pull mode).
MassFlowReqd / QmReqd Calc Outlet mass flowrate required applied to the outlet pipe (minimum of above 2 specifications).
MassFlow / Qm Calc Actual outlet mass flowrate of the outlet stream.
VolFlow / Qv Calc Actual outlet volumetric flowrate of the outlet stream.

Outlets tab page

Notes:

  1. All gases exit via the Gas Vent and cannot exit via normal Outlet links.
  2. If no Gas Vent is connected, then any Gas will exit via an automatically created Gas Spill direct link.
Tag (Long/Short) Input/ Calc Description
(The following group of tags are shown for each Product outlet stream connected to the Tank)
XXX ...
ConnectedPipe Display The tag of the connected pipe.
Order Display The order used for determining outlet flows.
Filter None All liquid and solid material will be able to exit via the connected pipe.
Block-Solids Solids will be not be allowed to exit via the connected pipe.
Block-Liquids Liquids will be not be allowed to exit via the connected pipe.
Composition Allows the user to specify the solid, liquid and vapour fractions.
Individual Phase Allows the user to specify an individual phase to draw from the tank.
Composition.SolidFrac / Sf Input Only visible if Filter = Composition. The required solid fraction of the stream.
Composition.LiquidFrac / Lf Input Only visible if Filter = Composition. The required liquid fraction of the stream.
Composition.VapourFrac / Vf Input Only visible if Filter = Composition. The required vapour fraction of the stream.
IPhase / IPh Input Only visible if Filter = Individual Phase. The required individual phase of the stream.
HeightFrac Input The connection height of the pipe on the tank, expressed as a percentage or fraction of the tank height. Material will not flow out of the pipe unless the level in the tank reaches the height of the pipe.

Notes

  1. If multiple pipes are connected at the same height, then depending on capacities, the behaviour for calculation of flows for each pipe (and spill) may be undefined. It is recommended to have each outlet pipe at a different level. (For example, when 2 outlet pipes have them at 99.8% and 99.9%.)
  2. The IO connections are sorted in the order of connection height. Therefore, if you make a change to the IO connection height, please double check the IO "Link name" before configuring the IO, as the IO display order may have changed.
XXX ...
Outlet XXX
(These Output connection tags are also available on the Pipe access window. Any changes made here will be updated on the pipe access window and vice-versa.)
CapacityControl Off The maximum mass flow through the outlet will be set to unlimited amount (uncontrolled).
ByMassFlow The user can specify the maximum mass flow through the outlet.
ByVolumeFlow The user can specify the maximum volumetric flow through the outlet.
Qm.ReqdCapacity / Capacity Input Visible with the ByMassFlow method. The required pipe Capacity in mass flow.
Qm.MinCapacity / MinCap Input Visible with the ByMassFlow method. The minimum user specified flow capacity by mass.
Qm.MaxCapacity / MaxCap Input Visible with the ByMassFlow method. The maximum user specified flow capacity by mass. Enter * for unlimited flow.
Qv.ReqdCapacity / Capacity Input Visible with the ByVolumeFlow method. The required pipe Capacity in volumetric flow.
Qv.MinCapacity / MinCap Input Visible with the ByVolumeFlow method. The minimum user specified flow capacity by volume.
Qv.MaxCapacity / MaxCap Input Visible with the ByVolumeFlow method. The maximum user specified flow capacity by volume. Enter * for unlimited flow.
MeasRho Display The stream density used when converting between mass and volume flows.
OverCapacity Spill If more material enters the pipe then the Maximum Capacity value, then the excess material will be 'spilled' and sent to the Spills area.
Accept If more material enters the pipe then the Maximum Capacity value, then the pipe must accept the excess material.
BatchMethod None The Batch functionality is not enabled.
Total Mass The Batch functionality is enabled and the required batch size is defined in terms of Mass flow. Further fields will become visible if this option is selected allowing the user to set the required batch mass.
Total Volume The Batch functionality is enabled and the required batch size is defined in terms of Volume flow. Further fields will become visible if this option is selected allowing the user to set the required batch volume.
The following fields will be visible if Total Mass is selected as the Batch method.
M.BatchAddition Input The Mass of the required Batch. This amount of material will be allowed to flow out of the pipe at the rate specified in Qm.Capacity or Qv.Capacity.
When this value is set the amount of material will be added to the amount of material already in M.BatchRemaining (the field below), and then this field will revert to 0.
M.BatchRemaining Calc / Input The Mass of material currently in a Batch, i.e. the amount of material in a Batch that still has to flow through the pipe. Normally this value is initialised at the start of a run and then it is calculated by SysCAD from the amount required in M.BatchAddition and the amount already delivered by the batch.
However, the user may set this value and hence override the calculated Batch amount at any stage.
If the users sets this as Undefined (or '*') this is equivalent to any infinite Batch and therefore the flow through the pipe will not be restricted.
M.BatchTotal Display The Total Mass that has flowed through the pipe using the Batch addition method.
The following fields will be visible if Total Volume is selected as the Batch method.
V.BatchAddition Input The Volume of the required Batch. This amount of material will be allowed to flow out of the pipe at the rate specified in Qm.Capacity or Qv.Capacity.
When this value is set the amount of material will be added to the amount of material already in V.BatchRemaining (the field below), and then this field will revert to 0.
V.BatchRemaining Calc / Input The Volume of material currently in a Batch, i.e. the amount of material in a Batch that still has to flow through the pipe. Normally this value is initialised at the start of a run and then it is calculated by SysCAD from the amount required in V.BatchAddition and the amount already delivered by the batch.
However, the user may set this value and hence override the calculated Batch amount at any stage.
If the users sets this as Undefined (or '*') this is equivalent to any infinite Batch and therefore the flow through the pipe will not be restricted.
V.BatchTotal Display The Total Volume that has flowed through the pipe using the Batch addition method.
The following fields will be visible if Total Mass or Total Volume is selected as the Batch method.
BatchState None No Batch mode has been set.
Inactive A Batch method has been selected, but the Batch is undefined.
Busy A Batch method has been selected, there is material remaining in the Batch, and hence there is flow in the pipe due to the Batch.
Stop Flow A Batch method has been selected, there is NO material remaining in the Batch, and hence there is no flow in the pipe, i.e. the Batch will prevent any flow in the pipe.
BatchClearOnEmpty Tickbox If enabled, any remaining batch amount will be cleared on Empty action command.
BatchUsePreset Tickbox This enables the use of Preset for the Batch amount.
M or V.BatchUsePreset Input The Mass or Volume of the Batch when the model is Preset. Refer to Actions Commands - Preset for more information.

TCE tab page

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
This program contains ChemApp Copyright GTT-Technologies, Germany
Chemistry Model
ChemModel...
UnitTag List The tag of the relevant ChemApp Model Configuration unit model- this may be chosen from the drop down list of all ChemApp Model Configuration unit models available in the project.
ModelCfgTagUsed/ModelCfgTag Display The tag of the relevant ChemApp Model Configuration unit model.
Check Check Tag.png If the user clicks on this button, SysCAD will check that the UnitTag is a valid ChemApp Model Configuration unit model.
ConnOK Tickbox If SysCAD finds a valid ChemApp Model Configuration unit model, then this field will be enabled.
Status OK The specified chemistry model (ChemApp Model Configuration) has been initialised correctly and the database file has been found and loaded correctly.
ChemModel Tag not Specified No tag has been specified for the Chemistry Model. Specify the desired Chemistry Model (ChemApp Model Configuration) in the UnitTag field.
Valid ChemModel Tag Required The tag specified for the Chemistry Model in the UnitTag field is invalid and needs to be corrected.
Init Required The specified Chemistry Model (ChemApp Model Configuration) needs to be initialised.
ChemModel Load Required The database of the specified Chemistry Model (ChemApp Model Configuration) needs to be loaded.
DLL or Version Error There is a problem with the ChemApp DLL or version.
Init Failed Initialisation of the specified Chemistry Model (ChemApp Model Configuration) has been attempted but failed.
Select actions if species unmapped
FwdSpMap.UnmappedAction Stop Solver Any unmapped SysCAD species will cause the solver to stop, user will need to fix the species mapping before solving again.
Bypass Any unmapped SysCAD species will be bypassed, i.e. will not be present in the ChemApp input
RevSpMap.UnmappedAction Make Inactive Any unmapped SysCAD species will cause the model to be inactive.
Stop Solver Any unmapped SysCAD species will cause the solver to stop, user will need to fix the species mapping before solving again.
Allow Solve Any unmapped SysCAD species will be ignored. Model will solve but will have a mass balance error.
ActionOnError Continue The model will continue solving if the ChemApp calculation fails.
Pause The model will pause solving if the ChemApp calculation fails.
Stop The model will stop solving if the ChemApp calculation fails.
Requirements
Model None (Off) No calculations will be performed and input=output.
Side Calc The results from the ChemApp calculation will be displayed but will not be applied to the output stream (input composition = output composition). This is similar to using the ChemApp Side Calc Model.
Reactor The results from the ChemApp calculation will be applied to the output stream, potentially affecting the composition and temperature/enthalpy of the stream.
UseSysCADVLE / VLE.On Tickbox Only visible if Model = Reactor. Allows user to switch on SysCAD VLE calculations. If ticked, then VLE tab will appear.
VLEModel Display Displays the VLE model used.
UseCFE Tickbox If this is ticked, then the CFE (Constrained Free Energy) tab page will appear.
  • If CFE is not available, this ticked box will be greyed out.
  • This option allows a portion of a species to be locked up and not allowed to react.
  • Applying CFE can have a significant effect on the final composition, use of this feature requires detailed knowledge of the process chemistry.
WithBypass Tickbox If this is ticked, then the Bypass tab page will appear.
Select dependent variable and target value
OpMode...
OpMode Temperature The target variable is the Temperature of the final solution.
FeedT The target variable is the Temperature of the feed solution.
Enthalpy CHEMAPP The target variable is the Enthalpy of the final solution. ChemApp Enthalpy is maintained.
PhaseFormation Available in full ChemApp only. The target variable is the amount of a particular phase present in the final solution.
PhasePrecipitation Available in full ChemApp only. The target variable is the point of precipitation of a second phase from a single phase. For example, if you have a stream which is entirely gas phase, you can calculate the temperature at which a second phase starts to appear.
TemperatureReqd / T_Reqd Input Only visible if OpMode = Temperature. The user specified target temperature for the final solution.
dEnth.Reqd / dH.Reqd Input Only visible if OpMode = Enthalpy CHEMAPP. The user specified target duty.
CalcEnthalpy Tickbox Visible when OpModeEnthalpy CHEMAPP. If the calculation requires a heat balance, then this option should be selected. If heat balance is not required, untick this option to save on computation time.
Note: unticking this option will also remove the enthalpy display from the Input and Output tabs.
SelPhase... (only visible if OpMode = PhaseFormation or PhasePrecipitation)
Filter Input Only visible if OpMode = PhaseFormation or PhasePrecipitation. Allows user to optionally shorten the Phase Selection list (Phase) by entering in some letters from the desired phase.
Phase List Only visible if OpMode = PhaseFormation or PhasePrecipitation. The user can select one phase from the list of all phases in the ChemApp database. The list will not show all phases if user has entered some letters in the Filter field above.
MoleBasis Tickbox Only visible if OpMode = PhaseFormation. Selecting this tickbox allows user to specify the target mole flow. If this is not selected, then mass flow is used.
Phase.MassFlowReqd / Phase.QmReqd Input Only visible if OpMode = PhaseFormation and MoleBasis = unticked. The user specified mass flow of the chosen phase/species that is to be formed.
Phase.MoleFlowReqd / Phase.QMlReqd Input Only visible if OpMode = PhaseFormation and MoleBasis = ticked. The user specified moles of the chosen phase/species that is to be formed.
Select independent variable to adjust to achieve target (The following section is only displayed if OpModeTemperature or FeedT)
AdjustVar...
Method AdjustT The chosen independent variable for adjustment is Temperature.
InitTemperature / InitT Input Only visible if Method = AdjustT. The initial guess to be used for the temperature of the final solution.
MaxTemperature / MaxT Input Only visible if Method = AdjustT. The maximum temperature of the final solution.
Target calculation details (only displayed if OpModeTemperature or FeedT)
TargCalc...
UseRelaxation Tickbox
RelaxationFactor Input The RelaxationFactor, used when UseRelaxation is ticked. Values limits: 0.001 < RelaxationFactor < 5.
Settings TargSolv Reset Button.png If the user clicks on this button, the all the target solver settings will be reset to their default values.
ChemApp Environmental Heat Transfer
ChemApp.HeatLossMethod None No heat transfer between the unit and the environment.
Fixed HeatFlow The user specifies a fixed heat loss between the unit and the environment.
Ambient SysCAD calculates the overall heat loss based on user specified HTC and Area and the temperature difference between the Feed and environmental temperatures. The environmental temperature is assumed to remain constant.
ChemApp.EHX.HeatLossReqd Input Visible when the HeatLossMethod = Fixed HeatFlow. The required heat loss.
ChemApp.EHX.HTC Input Visible when the HeatLossMethod = Ambient. The Overall Heat Transfer coefficient.
ChemApp.EHX.Area Input Visible when the HeatLossMethod = Ambient. The Heat Transfer area.
ChemApp.EHX.AmbientT Display Visible when the HeatLossMethod = Ambient. The ambient temperature. The ambient temperature is specified in the Plant Model - Environment_Tab
ChemApp.EHX.HeatLoss Calc Visible when the HeatLossMethod = Ambient. The calculated heat flowrate.
Options
ShowQUnmapped Tickbox Allows the user to view the QUnmapped and associated tab pages. See Material Flow Section. This is the SysCAD species flows which are not mapped to ChemApp species, and therefore are not taken into account in the ChemApp calculation.
ShowQRxnUnmapped Tickbox Allows the user to view the QRExnUnmapped and associated tab pages. See Material Flow Section.
ShowQBypass Tickbox Only visible when WithBypass is ticked. Allows the user to view the QBypass and associated tab pages. See Material Flow Section. This is the SysCAD species flows which bypass the ChemApp calculation.
ShowQRxnBypass Tickbox Only visible when WithBypass is ticked. Allows the user to view the QRxnBypass and associated tab pages. See Material Flow Section.
ShowRxnDiff Tickbox Allows the user to view the Diff tab page. This shows the difference between the mapped input stream seen by ChemApp and the ChemApp calculation results.
PhaseElemDeportment Tickbox If this is ticked, then the PhDeport tab page will appear. This tab shows the mass movement of elements for the Solid, Liquid and Gas phases.
IPhaseElemDeportment Tickbox If this is ticked, then the IPhDeport tab page will appear. This shows how the elements move between phases due to the ChemApp calculation results.
ShowPlotter Tickbox This option is only visible if this model has been successfully run. Allows the user to perform a parameter sweep using the product stream of the side calculator. If this is ticked, then the ParamSweep tab page will appear.
DebugMode Tickbox Allows the user to using the debug mode of ChemApp. When this mode is enabled, a log file will be written to showing the stream inputs seen by ChemApp and calculation results generated by ChemApp. All results in log file are in a per second time basis, i.e. kJ = kW, MJ = MW, etc.
DebugErrorFile OpenFileButton.png Only visible when DebugMode is ticked. Opens the error debug file that was just written to by the unit operation.
DebugMessageFile OpenFileButton.png Only visible when DebugMode is ticked. Opens the message debug file that was just written to by the unit operation.

CFE tab page

This tab is only visible if the UseCFE option is enabled on the TCE tab page.

  • This option allows a portion of a species to be locked up and not allowed to react.
  • Applying CFE can have a significant effect on the final composition, use of this feature requires detailed knowledge of the process chemistry.
  • This feature is unavailable if using SysCAD VLE with ChemApp.
Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Constrained Free Energy (CFE) Configuration
CFE...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
Filter View
Filter Button - Filter On.png
Button - Filter Off.png
This button will enable or disable the species filter options.
ShowUnmapped
(Only visible if Filter is enabled)
Tickbox When enabled, all species will be displayed. When disabled, only species that are mapped to a SysCAD species will be shown.
Phases
(Only visible if Filter is enabled)
All No filtering of species based on phase.
Solids Only show solid phase species, hide other species.
Liquids Only show liquid phase species, hide other species.
Vapours Only show vapour (gaseous) phase species, hide other species.
Solids & Liquids Only show solid and liquid phase species, hide other species.
Solids & Vapours Only show solid and vapour (gaseous) phase species, hide other species.
Liquids & Vapours Only show liquid and vapour (gaseous) phase species, hide other species.
IPhase Only show "IPhase" individual phase species, hide other species. The individual phases shown will depend on the ChemApp database chosen.
Filters Display Always set to 'Content'.
Content
(Only visible if Filter is enabled)
All No filtering of species based on element or name.
Contains Any Element This will display all species that contain any of the elements entered in their elemental definition.
Contains All Elements This will display only species that contain ALL of the elements entered in their elemental definition.
Starts with ... This will display species that start with the text entered based on the short or long species tag depending on the current SpeciesTag selection.
Contains any ... This will display species that contain the text entered in the currently displayed short or long species tag.
Contains All ... This will display species that contain ALL the separate text entered in the currently displayed short or long species tag.
Select Input Only visible if Filter is enabled and Content is NOT set to All. The user specified Elements or text to filter the species list. Refer to Species Filter for more information and examples.
(The following tables (one per phase) display the ChemApp species from the selected database. The user can set the Inert Fraction for each species. Note that liquid ions are not shown on this page as the Inert Fractions cannot be set for them.)
(Each table has the following column (one row per ChemApp species):)
InertFrac Input The user specified fraction of the species that is considered inert, i.e. cannot react to form other species/ions. The presence of the inert fraction is still taken into account when calculating stream properties. This is only available as an input for molecular species (not ions).

Bypass tab page

This tab is only visible if the WithBypass option is enabled on the TCE tab page. This will allow some or all of the SysCAD species to bypass the thermodynamic engine calculations.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Specify Bypass of Feed
BypassMode Species A bypass fraction can be set for each species in the project.
Phases A bypass fraction can be set for each phase (Solid, Liquid or Vapour) in the project.
BypassUnmapped BypassUnmapped Button.png If this button is pressed then the bypass fraction for all Unmapped Species will be set to 100%. This is only relevant if BypassMode = Species.
NOTE: There is no automatic undo for this function. It is recommended to bypass all species in the SysCAD model which are not present in the ChemApp model you are using.
ShowUnmappedSpecies Tickbox If ticked, all the unmapped species will be displayed in a list immediately under this field.
BypassSpCount Calc The number of species to be bypassed.
PhaseBypass... (only displayed if BypassMode = Phases)
PhaseBypass.Solid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD solid species. A non-zero value will allow some or all (100%) of the SysCAD solid species to bypass the thermodynamic engine calculations.
PhaseBypass.Liquid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD liquid species. A non-zero value will allow some or all (100%) of the SysCAD liquid species to bypass the thermodynamic engine calculations.
PhaseBypass.Vapour.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD vapour species. A non-zero value will allow some or all (100%) of the SysCAD vapour species to bypass the thermodynamic engine calculations.
The remaining fields are only displayed if BypassMode = Species)
On Button - Filter On.png
Button - Filter Off.png
This button will enable or disable the species filter options.
Phases
(Only visible if Filter is enabled)
All No filtering of species based on phase.
Solids Only show solid phase species, hide other species.
Liquids Only show liquid phase species, hide other species.
Vapours Only show vapour (gaseous) phase species, hide other species.
Solids & Liquids Only show solid and liquid phase species, hide other species.
Solids & Vapours Only show solid and vapour (gaseous) phase species, hide other species.
Liquids & Vapours Only show liquid and vapour (gaseous) phase species, hide other species.
IPhase Only show "IPhase" individual phase species, hide other species. The individual phases shown will depend on the ChemApp database chosen.
Filters Display Always set to 'Content'.
Content
(Only visible if Filter is enabled)
All No filtering of species based on element or name.
Contains Any Element This will display all species that contain any of the elements entered in their elemental definition.
Contains All Elements This will display only species that contain ALL of the elements entered in their elemental definition.
Starts with ... This will display species that start with the text entered based on the short or long species tag depending on the current SpeciesTag selection.
Contains any ... This will display species that contain the text entered in the currently displayed short or long species tag.
Contains All ... This will display species that contain ALL the separate text entered in the currently displayed short or long species tag.
Select Input Only visible if Filter is enabled and Content is NOT set to All. The user specified Elements or text to filter the species list. Refer to Species Filter for more information and examples.
GroupValue Input The user specified bypass value that will be used for all species displayed when the Set to GroupValue button is pressed.
SetVisible Set to GroupValue.png When pressed, this button will set the bypass parameter for all species currently displayed (based on Filter settings) equal to the GroupValue.
SysCAD Feed Stream Bypass
(The following table displays all the SysCAD species in the project (unless restricted by the Filter settings). The table has the following column (one row per SysCAD species):)
Bypass.XXX Input The user specified Bypass fraction for SysCAD species XXX. A non-zero value will allow some or all (100%) of the SysCAD species to bypass the thermodynamic engine calculations.

RxnBypass tab page

This tab is only visible if the WithBypass option is enabled on the TCE tab page. This will allow some or all of the SysCAD species to bypass the thermodynamic engine calculations.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Specify Bypass during Solver Solution
RxnBypass...
BypassMode Species A bypass fraction can be set for each species in the project.
Phases A bypass fraction can be set for each phase (Solid, Liquid or Vapour) in the project.
BypassUnmapped BypassUnmapped Button.png If this button is pressed then the bypass fraction for all Unmapped Species will be set to 100%. This is only relevant if BypassMode = Species.
NOTE: There is no automatic undo for this function. It is recommended to bypass all species in the SysCAD model which are not present in the ChemApp model you are using.
ShowUnmappedSpecies Tickbox If ticked, all the unmapped species will be displayed in a list immediately under this field.
BypassSpCount Calc The number of species to be bypassed.
PhaseBypass... (only displayed if BypassMode = Phases)
PhaseBypass.Solid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD solid species. A non-zero value will allow some or all (100%) of the SysCAD solid species to bypass the thermodynamic engine calculations.
PhaseBypass.Liquid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD liquid species. A non-zero value will allow some or all (100%) of the SysCAD liquid species to bypass the thermodynamic engine calculations.
PhaseBypass.Vapour.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD vapour species. A non-zero value will allow some or all (100%) of the SysCAD vapour species to bypass the thermodynamic engine calculations.
The remaining fields are only displayed if BypassMode = Species)
On Button - Filter On.png
Button - Filter Off.png
This button will enable or disable the species filter options.
Phases
(Only visible if Filter is enabled)
All No filtering of species based on phase.
Solids Only show solid phase species, hide other species.
Liquids Only show liquid phase species, hide other species.
Vapours Only show vapour (gaseous) phase species, hide other species.
Solids & Liquids Only show solid and liquid phase species, hide other species.
Solids & Vapours Only show solid and vapour (gaseous) phase species, hide other species.
Liquids & Vapours Only show liquid and vapour (gaseous) phase species, hide other species.
IPhase Only show "IPhase" individual phase species, hide other species. The individual phases shown will depend on the ChemApp database chosen.
Filters Display Always set to 'Content'.
Content
(Only visible if Filter is enabled)
All No filtering of species based on element or name.
Contains Any Element This will display all species that contain any of the elements entered in their elemental definition.
Contains All Elements This will display only species that contain ALL of the elements entered in their elemental definition.
Starts with ... This will display species that start with the text entered based on the short or long species tag depending on the current SpeciesTag selection.
Contains any ... This will display species that contain the text entered in the currently displayed short or long species tag.
Contains All ... This will display species that contain ALL the separate text entered in the currently displayed short or long species tag.
Select Input Only visible if Filter is enabled and Content is NOT set to All. The user specified Elements or text to filter the species list. Refer to Species Filter for more information and examples.
GroupValue Input The user specified bypass value that will be used for all species displayed when the Set to GroupValue button is pressed.
SetVisible Set to GroupValue.png When pressed, this button will set the bypass parameter for all species currently displayed (based on Filter settings) equal to the GroupValue.
SysCAD Feed Stream Bypass
(The following table displays all the SysCAD species in the project (unless restricted by the Filter settings). The table has the following column (one row per SysCAD species):)
Bypass.XXX Input The user specified Bypass fraction for SysCAD species XXX. A non-zero value will allow some or all (100%) of the SysCAD species to bypass the thermodynamic engine calculations.

ChemAppResults tab page

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
ChemApp Calculation Results Summary
Feed Mass Summary
Bypass.Mass / M Display The mass of material in the feed which bypasses the calculation due to user selection of bypass species. Use ShowQBypass to view full stream.
Unmapped.Mass / M Display The mass of material in the feed which is not forward mapped to a species and therefore bypasses the calculation. Use ShowQUnmapped to view full stream.
ChemApp.Feed.Mass / M Display The mass of material in the feed to the ChemApp calculation.
TotalFeed.Mass / M Display The total feed mass to the ChemApp model block. Sum of bypasses and feed to ChemApp calculation.
Product Mass Summary
ChemApp.Prod.Mass / M Display The mass flow of material in the product of the ChemApp calculation. Same value as tag Prod.Qm.
RxnBypass.Mass / M Display
RxnUnmapped.Mass / M Display The mass of material in the product which is not reverse mapped to SysCAD species.
TotalProd.Mass / M Display The total product mass for the ChemApp model block. Sum of bypasses and product of ChemApp calculation.
Solids Yield
Solids.Yield Display The solids concentration in the product stream.
Solids.Precip Display The change in solids flow, feed-product. A positive value indicates precipitation has occurred. A negative value indicates dissolution has occurred.
Content Properties Summary
Prod...
Temperature / T Display The Temperature of the final solution.
Pressure / P Display The Pressure of the final solution.
Mass / M Display The Mass of the final solution.
Hf@T Display The Enthalpy of the final solution per unit mass.
Enthalpy / totHf@T Display The Enthalpy of the final solution.
FreeEnergy / Gf@T Display The Free Energy of the final solution.
Entropy Display The entropy of the final solution.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all phases/species that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all phases/species will be displayed, including those with zero mass flow.
Note this setting applies to the subsequent pages as well.
Feed...
Feed Phase Content Summary
(The following table displays a summary of results for the different phases. The table has the following columns (one row per phase)):
Mass / M Display The mass of the relevant phase in the feed.
MassFrac / Mf Display The mass fraction of the relevant phase in the feed.
Moles / Ml Display The moles of the relevant phase in the feed.
MoleFrac / Mlf Display The mole fraction of the relevant phase in the feed.
Prod...
Prod Phase Content Summary
(The following table displays a summary of results for the different phases. The table has the following columns (one row per phase)):
Mass / M Display The mass of the relevant phase in the final solution.
MassFrac / Mf Display The mass fraction of the relevant phase in the final solution.
Moles / Ml Display The moles of the relevant phase in the final solution.
MoleFrac / Mlf Display The mole fraction of the relevant phase in the final solution.
ChemApp Energy Balance
ChemApp.HeatFlow Display Difference in enthalpy between the product and feed of the ChemApp reactions calculated by ChemApp.
Bypass.HeatFlow Display The heat required to adjust the temperature and pressure of the bypass stream to exit conditions.
HeatLoss Display The environmental heat loss.
HeatFlow Display The heat flow required to achieve the product conditions relative to the feed conditions. Includes environmental heat loss if applicable. This is calculated by ChemApp and accounts for bypass and heat loss. Note that Bypass heat is calculated by SysCAD.
Forward Mapping Summary
FwdMap.ScdFeed Display This displays mass and SysCAD enthalpy of the feed stream to ChemApp before mapping and after bypass and unmapped are removed.
FwdMap Display This displays mass and ChemApp enthalpy of the Input stream to ChemApp after forward mapping. The enthalpy of the FwdMap stream and the FwdMap.ScdFeed stream are likely to be different. Some reasons for differences include differences in enthalpy values for pure species and the incorporation of additional solution thermodynamics terms.
FwdMap.Diff Display This displays the difference in mass and enthalpy between the feed stream and Input stream. There should never be differences in mass. Small enthalpy differences are expected but large differences may indicate issues with SysCAD database enthalpy data.
FwdMap.RelDiff Display This displays the relative difference in mass and enthalpy between the feed stream and Input stream. There should never be differences in mass. Small enthalpy differences are expected but large differences may indicate issues with SysCAD database enthalpy data.
Reverse Mapping Summary
RevMap.TCEProd Display This displays mass and ChemApp enthalpy of the Output stream from ChemApp. The enthalpy of the RevMap.TCEProd stream and the RevMap stream are likely to be different. Some reasons for differences include differences in enthalpy values for pure species and the incorporation of additional solution thermodynamics terms.
RevMap Display This displays mass and SysCAD enthalpy of the Prod stream after reverse mapping.
RevMap.Diff Display This displays the difference in mass and enthalpy between the Output stream and Prod stream. There should never be differences in mass. Small enthalpy differences are expected but large differences may indicate issues with SysCAD database enthalpy data.
RevMap.RelDiff Display This displays the relative difference in mass and enthalpy between the Output stream and Prod stream. There should never be differences in mass. Small enthalpy differences are expected but large differences may indicate issues with SysCAD database enthalpy data.
Copy Reverse Mapping Reactions to Clipboard
RevMap.IonRxns RevMapIonsCopyToClipboard.png Pushing this button copies to the clipboard a list of reactions that were executed to perform the reverse mapping. These can then be pasted into Excel to generate a table.
Calculation Summary
Summary...
LastCalcType Display This displays the type of calculation (OpMode) used for the last calculation.
Remove Remove Duplicates.png If the user clicks on this button, SysCAD will remove duplicate error messages received.
ErrorCount Display The total number of errors encountered in the last calculation.
ErrorXX Display If there are error messages associated with the last calculation, they will be displayed here.
ConvergenceError Display The largest numerical convergence error. This is often zero when the solution converges with no errors.

Input tab page

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Content Properties Summary
Feed...
Temperature / T Display The Temperature of the feed solution. This is calculated using the SysCAD enthalpy context.
Pressure / P Display The Pressure of the feed solution.
Mass / M Display The Mass of the feed solution.
Hf@T Display The Enthalpy of the feed solution per unit mass. This is calculated by ChemApp.
Enthalpy / totHf@T Display The Enthalpy of the feed solution. This is calculated by ChemApp.
FreeEnergy / Gf@T Display The Free Energy of the feed solution.
Entropy Display The entropy of the feed solution.
Feed...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all species that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all species will be displayed, including those with zero mass flow.
StreamView Mass.png
Molar.png
If the Mass button is clicked, the species will be shown in mass flow view.
If the Mole button is clicked, the species will be shown in mole flow view.
Stream Copy to Clipboard Button.png Mass Copy stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Mole Copy stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Unmapped Mass Copy unmapped stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
Unmapped Mole Copy unmapped stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
(The following tables display the mass/moles, mass/mole fraction of the individual species.)
(Each table (one for each phase) has the following columns (one row for each species):)
Mass / M Display Visible when StreamView = Mass. The mass of the species in the feed stream.
MassFrac / Mf Display Visible when StreamView = Mass. The mass fraction of the species in the feed stream.
PhaseMassFrac / IPh:Mf Display Visible when StreamView = Mass. The mass fraction of the species in the displayed phase.
Moles / Ml Display Visible when StreamView = Mole. The moles of the species in the feed stream.
MoleFrac / Mlf Display Visible when StreamView = Mole. The mole fraction of the species in the feed stream.
PhaseMoleFrac / IPh:Mlf Display Visible when StreamView = Mole. The mole fraction of the species in the displayed phase.


Output tab page

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Content Properties Summary
Prod...
Temperature / T Display The Temperature of the product solution. This is calculated by ChemApp.
Pressure / P Display The Pressure of the product solution.
Mass / M Display The Mass of the product solution.
Hf@T Display The Enthalpy of the product solution per unit mass. This is calculated by ChemApp.
Enthalpy / totHf@T Display The Enthalpy of the product solution. This is calculated by ChemApp.
FreeEnergy / Gf@T Display The Free Energy of the product solution.
Entropy Display The entropy of the product solution.
Prod...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all species that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all species will be displayed, including those with zero mass flow.
StreamView Mass.png
Molar.png
If the Mass button is clicked, the species will be shown in mass flow view.
If the Mole button is clicked, the species will be shown in mole flow view.
Stream Copy to Clipboard Button.png Mass Copy stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Mole Copy stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Unmapped Mass Copy unmapped stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
Unmapped Mole Copy unmapped stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
(The following tables display the mass/moles, mass/mole fraction of the individual species.)
(Each table (one for each phase) has the following columns (one row for each species):)
Mass / M Display Visible when StreamView = Mass. The mass of the species in the product stream.
MassFrac / Mf Display Visible when StreamView = Mass. The mass fraction of the species in the product stream.
PhaseMassFrac / IPh:Mf Display Visible when StreamView = Mass. The mass fraction of the species in the displayed phase.
Moles / Ml Display Visible when StreamView = Mole. The moles of the species in the product stream.
MoleFrac / Mlf Display Visible when StreamView = Mole. The mole fraction of the species in the product stream.
PhaseMoleFrac / IPh:Mlf Display Visible when StreamView = Mole. The mole fraction of the species in the displayed phase.
Activity Display Only shown for non-gaseous species. The activity of the species.
Fugacity Display Only shown for gaseous species. The fugacity of the species.

Diff tab page

This tab is only visible if ShowRxnDiff is ticked. The displayed results are the difference between input and output contents.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Content Properties Summary
Diff...
Temperature / T Display The Temperature difference between the feed and product solutions.
Pressure / P Display The Pressure difference between the feed and product solutions.
Mass / M Display The Mass difference between the feed and product solutions.
Hf@T Display The Enthalpy difference between the feed and product solutions per unit mass. This is calculated by ChemApp.
Enthalpy / totHf@T Display The Enthalpy difference between the feed and product solutions. This is calculated by ChemApp.
FreeEnergy / Gf@T Display The Free Energy difference between the feed and product solutions.
Entropy Display The entropy difference between the feed and product solutions.
Diff...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all species that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all species will be displayed, including those with zero mass flow.
StreamView Mass.png
Molar.png
If the Mass button is clicked, the species will be shown in mass flow view.
If the Mole button is clicked, the species will be shown in mole flow view.
Stream Copy to Clipboard Button.png Mass Copy stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Mole Copy stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard.
Unmapped Mass Copy unmapped stream contents to clipboard, mass basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
Unmapped Mole Copy unmapped stream contents to clipboard, mole basis, for pasting into Excel. If Zeros is set to hide, zero values will not be copied to the clipboard. Unmapped species are those which will not be mapped to the exiting SysCAD stream.
(The following tables display the mass/moles, mass/mole fraction of the individual species.)
(Each table (one for each phase) has the following columns (one row for each species):)
Mass / M Display Visible when StreamView = Mass. The difference in mass of the species.
MassFrac / Mf Display Visible when StreamView = Mass. The difference in mass fraction of the species.
PhaseMassFrac / IPh:Mf Display Visible when StreamView = Mass. The difference in mass fraction of the species in the displayed phase.
Moles / Ml Display Visible when StreamView = Mole. The difference in moles of the species.
MoleFrac / Mlf Display Visible when StreamView = Mole. The difference in mole fraction of the species.
PhaseMoleFrac / IPh:Mlf Display Visible when StreamView = Mole. The difference in mole fraction of the species in the displayed phase.


ElemBal tab page

This tab performs an element balance between the ChemApp Input and Output streams and separately, between the SysCAD Input and Output streams.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
ElemBal...
Tol.SigDigits Input This provides an easy way to change the Tol.Rel value. For example, 4 here will set Tol.Rel = 1.00e-4. If user changes the Tol.Rel value, this value will also be updated.
Tol.Rel Input The relative tolerance for Element Balance (Input - Output). If the relative error is > Tol.Rel then an error is generated. The value of Tol.Rel shown/specified here is used in all ChemApp unit models which reference the same ChemApp Model Configuration unit model.
Tol.Abs Input The absolute tolerance for Element Balance (Input - Output). If the absolute error is > Tol.Abs then an error is generated. The value of Tol.Abs shown/specified here is used in all ChemApp unit models which reference the same ChemApp Model Configuration unit model.
ChemApp...
ElementBalanceView Mass.png
Molar.png
If the Mass button is clicked, the elements will be shown in mass flow view.
If the Mole button is clicked, the elements will be shown in mole flow view.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all elements that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all elements will be displayed, including those with zero mass flow.
ChemApp Element Balance
(The following table displays the mass/molar flows, and absolute and relative errors of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the ChemApp Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the ChemApp Output. The QRxnBypass stream is also included in this total. This can be viewed by clickingShowQRxnBypass.
AbsErr / M.Err Display Visible when ElementBalanceView = Mass. The difference in mass of the element between the ChemApp Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the ChemApp Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the ChemApp Output.
AbsErr / Ml.Err Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the ChemApp Output and Input.
RelErr Display The relative difference in amount of the element between the ChemApp Output and Input, relative to the Input.
Scd...
SysCAD Element Balance
(The following table displays the mass/molar flows, and absolute and relative errors of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the SysCAD Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the SysCAD Output. The QRxnBypass stream is also included in this total. This can be viewed by clickingShowQRxnBypass.
AbsErr / M.Err Display Visible when ElementBalanceView = Mass. The difference in mass of the element between the SysCAD Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the SysCAD Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the SysCAD Output.
AbsErr / Ml.Err Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the SysCAD Output and Input.
RelErr Display The relative difference in amount of the element between the SysCAD Output and Input, relative to the Input.

PhDeport tab page

This tab is only visible if PhaseElemDeportment is ticked. This tab shows the mass movement of elements for the Liquid, Solid and Gas phases.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
PD...
ElementBalanceView Mass.png
Molar.png
If the Mass button is clicked, the elements will be shown in mass flow view.
If the Mole button is clicked, the elements will be shown in mole flow view.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all elements that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all elements will be displayed, including those with zero mass flow.
ChemApp.Liquid...
ChemApp Deportment
(The following table displays the mass/moles, and absolute and relative changes of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the liquid phase of the Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the liquid phase of the Output.
Change / M.Chng Display Visible when ElementBalanceView = Mass. The change in mass of the element between the liquid phase of the Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the liquid phase of the Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the liquid phase of the Output.
Change / Ml.Chng Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the liquid phase of the Output and Input.
RelChange Display The relative change in the amount of the element between the liquid phase of the Output and Input, relative to the Input.
ChemApp.Solid...
ChemApp Deportment
(The following table displays the mass/moles, and absolute and relative changes of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the solid phase of the Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the solid phase of the Output.
Change / M.Chng Display Visible when ElementBalanceView = Mass. The change in mass of the element between the solid phase of the Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the solid phase of the Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the solid phase of the Output.
Change / Ml.Chng Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the solid phase of the Output and Input.
RelChange Display The relative change in the amount of the element between the solid phase of the Output and Input, relative to the Input.
ChemApp.Gas...
ChemApp Deportment
(The following table displays the mass/moles, and absolute and relative changes of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the gas phase of the Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the gas phase of the Output.
Change / M.Chng Display Visible when ElementBalanceView = Mass. The change in mass of the element between the gas phase of the Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the gas phase of the Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the gas phase of the Output.
Change / Ml.Chng Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the gas phase of the Output and Input.
RelChange Display The relative change in the amount of the element between the gas phase of the Output and Input, relative to the Input.

IPhDeport tab page

This tab is only visible if IPhaseElemDeportment is ticked. This tab shows the mass movement of elements for each ChemApp phase.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
IPD...
ElementBalanceView Mass.png
Molar.png
If the Mass button is clicked, the elements will be shown in mass flow view.
If the Mole button is clicked, the elements will be shown in mole flow view.
Zeros Hide Zeros.png
Show Zeros.png
If the Hide Zeros button is clicked, all elements that have NO mass flow will be hidden.
If the Show Zeros button is clicked, all elements will be displayed, including those with zero mass flow.
ChemApp.<ChemApp PHASE>...
ChemApp Deportment
(The following table displays the mass/moles, and absolute and relative changes of the individual elements.)
The table has the following columns (one row for each element):
MassIn / M.In Display Visible when ElementBalanceView = Mass. The mass of the element in the selected ChemApp phase of the Input.
MassOut / M.Out Display Visible when ElementBalanceView = Mass. The mass of the element in the selected ChemApp phase of the Output.
Change / M.Chng Display Visible when ElementBalanceView = Mass. The change in mass of the element between the selected ChemApp phase of the Output and Input.
MolesIn / Ml.In Display Visible when ElementBalanceView = Mole. The moles of the element in the selected ChemApp phase of the Input.
MolesOut / Ml.Out Display Visible when ElementBalanceView = Mole. The moles of the element in the selected ChemApp phase of the Output.
Change / Ml.Chng Display Visible when ElementBalanceView = Mole. The difference in moles of the element between the selected ChemApp phase of the Output and Input.
RelChange Display The relative change in the amount of the element between the selected ChemApp phase of the Output and Input, relative to the Input.

ParamSweep tab page

This tab is only visible if ShowPlotter is ticked and the model has been successfully run.

This tab allows the user to perform multiple calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Use tools on this page to generate tabular data on clipboard from parameter sweep
ParamSweep...
Method AdjustT The chosen independent variable is Temperature.
AdjustQMl The chosen independent variable is flow of an individual species.
MinTemperature / MinT Input Only visible if Method = AdjustT. The minimum temperature of the final solution in the data set.
MaxTemperature / MaxT Input Only visible if Method = AdjustT. The maximum temperature of the final solution in the data set.
SelPhase... (only visible if Method = AdjustQMl)
Filter Input Only visible if Method = AdjustQMl. Allows user to optionally shorten the Phase Selection list (SelPhase) by entering in some letters from the desired phase.
PhaseFilter List Only visible if Method = AdjustQMl. List of available phases to choose from. The list will not show all phases if user has entered some letters in the Filter field above.
SelSp... (only visible if Method = AdjustQMl)
Filter Input Only visible if Method = AdjustQMl. Allows user to optionally shorten the Species Selection list (TargetSpAdjust) by entering in some letters from the desired species.
TargSpAdjust List Only visible if Method = AdjustQMl. The user can select a single species from the list of all species in the ChemApp database to have its flow varied. The list will be limited to those in the selected phase (SelPhase) and will not show all species if user has entered some letters in the Filter field above.
MoleBasis Tickbox Only visible if Method = AdjustQMl. If this box is ticked, user specifies the minimum and maximum mole flow of selected species. If this is not ticked, user can specify these flows in terms of mass flow.
MinSpMassFlow / QmMin Input Only visible if Method = AdjustQMl and MoleBasis is not ticked. The minimum mass flow of the selected species in the final solution.
MaxSpMassFlow / QmMax Input Only visible if Method = AdjustQMl and MoleBasis is not ticked. The maximum mass flow of the selected species in the final solution.
MinSpMoleFlow / QMlMin Input Only visible if Method = AdjustQMl and MoleBasis is ticked. The minimum mole flow of the selected species in the final solution.
MaxSpMoleFlow / QMlMax Input Only visible if Method = AdjustQMl and MoleBasis is ticked. The maximum mole flow of the selected species in the final solution.
Prod.T Input The required temperature of the product stream.
Prod.P Input The required pressure of the product stream.
StepSize Input The step size between each data point. If the user changes this value, then SysCAD will automatically adjust DataPoints (Below). (=(Max-Min)/(DataPoints-1))
DataPoints Input The number of calculations to perform/rows of data to generate. If the user changes this value, then SysCAD will automatically adjust StepSize (Above). (=(Max-Min)/StepSize + 1)
IndVarRanges IndVar Defaults Button.png If the user clicks on this button, the inputs for the independent variable limits will be reset to their default values. (Applied to the temperature option only).
PlotDataCreate GenerateButton.png If the user clicks on this button, SysCAD will perform the requested calculations based on the chosen parameters, to generate the required data.
PlotDataTable GenerateData Button.png If the user clicks on this button, SysCAD will perform the requested calculations based on the chosen parameters, to generate the required data. SysCAD will also copy the generated data to the clipboard, allowing it to be pasted into an external program such as MS Excel.
Select Dependent Variables for Output
SelectSpecies / SelectSp Tickbox Allows the user to select species to be reported. If this option is enabled, the SpForPlot tab will appear.
ShowActCoeff / ShowAC Tickbox Only visible if the SelectSp option is enabled. If this option is enabled, the activity coefficients of the species selected on the SpForPlot tab will be reported.
HideZeros Tickbox Only visible if the SelectSp option is enabled. If this option is enabled, the outputted table will be filtered so that only species which have a non-zero value in any of the calculations in the sweep will be shown in the table.
ResultsType (only visible if the SelectSp option is enabled)
Flow The results generated will include the flows of the selected species in the final product stream.
Frac The results generated will include the overall fractions of the selected species in the final product stream.
PhaseFrac The results generated will include the phase fractions of the selected species in the final product stream.
SelectedSpCount Display Only visible if the SelectSp option is available. The number of species selected on the SpForPlot tab.
Select Properties For Output
PropertiesCount / PropsCount Input The number of properties to be included in the reported data set.
PropX List The property to be reported from the list of available properties. Note: This field is only visible if the entry for NumPropsForOutput is greater then 0. If there is one property then X=1. If there are two properties, then X=1 and X=2, etc.

SpForPlot tab page

This tab is only visible if the SelectSp option is enabled on the ParamSweep tab. It allows the user to select which species to be reported in the sets of data to be generated.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
SpForPlot...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
SelectVisible SelectVisibleButton.png User can select all the species which are currently visible in the access window. The ones that are visible may be limited by use of the Filter (see options below).
UnselectVisible UnselectVisibleButton.png User can unselect all the species which are currently visible in the access window. The ones that are visible may be limited by use of the Filter (see options below).
Filter View
Filter Button - Filter On.png
Button - Filter Off.png
This button will enable or disable the species filter options.
ShowUnmapped
(Only visible if Filter is enabled)
Tickbox When enabled, all species will be displayed. When disabled, only species that are mapped to a SysCAD species will be shown.
Phases
(Only visible if Filter is enabled)
All No filtering of species based on phase.
Solids Only show solid phase species, hide other species.
Liquids Only show liquid phase species, hide other species.
Vapours Only show vapour (gaseous) phase species, hide other species.
Solids & Liquids Only show solid and liquid phase species, hide other species.
Solids & Vapours Only show solid and vapour (gaseous) phase species, hide other species.
Liquids & Vapours Only show liquid and vapour (gaseous) phase species, hide other species.
IPhase Only show "IPhase" individual phase species, hide other species. The individual phases shown will depend on the ChemApp database chosen.
Filters Display Always set to 'Content'.
Content
(Only visible if Filter is enabled)
All No filtering of species based on element or name.
Contains Any Element This will display all species that contain any of the elements entered in their elemental definition.
Contains All Elements This will display only species that contain ALL of the elements entered in their elemental definition.
Starts with ... This will display species that start with the text entered based on the short or long species tag depending on the current SpeciesTag selection.
Contains any ... This will display species that contain the text entered in the currently displayed short or long species tag.
Contains All ... This will display species that contain ALL the separate text entered in the currently displayed short or long species tag.
Select Input Only visible if Filter is enabled and Content is NOT set to All. The user specified Elements or text to filter the species list. Refer to Species Filter for more information and examples.
(The following tables (one per phase) display the ChemApp species from the selected database. The user can select any number of species.)
(Each table has the following column (one row per ChemApp species):)
Select Tickbox The properties (selected on the ParamSweep tab) of the selected species will be reported when the Generate function (ParamSweep tab) is used.
SetAll...(displayed at the end of each phase)
SelectAll SelectAllButton.png User can select all the species in the relevant phase.
UnselectAll UnselectAllButton.png User can unselect all the species in the relevant phase.

Preset tab page

The Preset page contains a Copy to Clipboard button which copies the current temperature, pressure and composition of the Preset to the clipboard for pasting into external programs such as Excel.

This page is used to set the required composition of the Tank when it is Preset. This is identical in functionality to the DSp page used in Feeders.

Adding this Model to a Project

Insert into Configuration file

Sort either by DLL or Group.

 

DLL:

ScdChemApp.dll

Units/Links

TCE ChemApp:Dynamic: ChemApp Reactor Tank

or

Group:

Energy Transfer

Units/Links

TCE ChemApp:Dynamic: ChemApp Reactor Tank

See Model Selection for more information on adding models to the configuration file.


Insert into Project

 

Insert Unit

TCE ChemApp

Dynamic

ChemApp Reactor Tank

See Insert Unit for general information on inserting units.