Search results
Jump to navigation
Jump to search
Did you mean: eb evaluation data sections
- Flash Tank 2 (section EB (Evaluation Block)...)and would usually be the last sub-model evaluated. Other sub-models allowed as part of the Evaluation Block (EB) are Makeup Block (MU), Reaction Block (RB)9 KB (889 words) - 09:29, 2 February 2024
- Phase Change (PC) (section Data Sections)Navigation: Models ➔ Sub-Models ➔ Evaluation Blocks ➔ Phase Change (PC) Related Links: Evaluation Blocks, Solubility, Potash Solubility, Plant Model -9 KB (537 words) - 01:41, 6 September 2023
- enter the data in 2 columns. SysCAD will interpolate the data using the TSpline method. The easiest way to enter the data is to copy the data from a spreadsheet15 KB (1,831 words) - 09:49, 11 March 2024
- Feeder-Cross Page Connector (section Data Sections)the project. This section is only available in Dynamic mode. This section mainly has read only variables, except for the first section, Model. Model determines47 KB (2,683 words) - 09:04, 2 February 2024
- be enabled in the Evaluation Block (EB) in a unit. Therefore, the user must be careful to ensure that the order of evaluation in the EB will produce the36 KB (1,127 words) - 03:33, 5 April 2024
- Tank - Dynamic Mode (section Data Sections)selected, then NONE of the EB sub models will be available Two groups of sub-models are allowed in a Dynamic Tank: Evaluation Block (EB) sub-models that act43 KB (2,552 words) - 16:25, 25 January 2024
- Pipe (section EB (Flow Evaluation Block))disable Simplify and then the Evaluation Block (EB) will be visible. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled23 KB (1,392 words) - 10:18, 3 August 2023
- Thickener (section EB (Flow Evaluation Block))several sections: Thickener1 tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB.PhaseChange@T9 KB (803 words) - 05:13, 21 February 2024
- General Separator (section Data Sections)outlets. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible6 KB (942 words) - 09:26, 2 February 2024
- no BPE data in the species database, then the equilibrium point will be that of saturated steam, as found in Steam Tables. If there is BPE data in the26 KB (2,038 words) - 09:28, 2 February 2024
- disable Simplify and then the Evaluation Block (EB) will be visible. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled28 KB (655 words) - 19:00, 2 August 2023
- Flotation Cell (section EB (Evaluation Block))chosen. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible19 KB (1,611 words) - 05:14, 7 February 2024
- Washer (section EB (Flow Evaluation Block))operate. Please see General Description or Notes in the Inputs and Outputs section for more information on washer connections based on mixing efficiency /15 KB (1,264 words) - 05:13, 21 February 2024
- in SysCAD can be selectively enabled in individual units using the Evaluation Block (EB). Solubility Information in Pipes - The information shown in the3 KB (401 words) - 11:08, 17 May 2023
- Drum Filter (section EB (Flow Evaluation Block))consists of three sections: DrumFilter tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On is11 KB (855 words) - 04:36, 21 February 2024
- Tank (section Data Sections)information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled on the first tab. MU - Optional tab12 KB (1,353 words) - 18:49, 25 January 2024
- Tie (section Data Sections)unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. MU - Optional tab, or multiple tabs9 KB (1,053 words) - 09:22, 2 February 2024
- Disk Centrifuge (section EB (Flow Evaluation Block))environment. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible8 KB (672 words) - 04:35, 21 February 2024
- Classifier (section EB (Flow Evaluation Block))several sections, Classifier tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB.PhaseChange@T8 KB (643 words) - 04:18, 21 February 2024
- Underflow Washer (section EB (Feed Evaluation Block))sub-models in the Feed section, Underflow and Overflow sections. The following sub-models are available in each section: The Feed section, EB, allows the user11 KB (988 words) - 11:32, 21 February 2024
- consists of several sections, CCWasher tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On is enabled11 KB (919 words) - 04:35, 21 February 2024
- Reverse Osmosis (RO) Unit (section Data Sections)unit PC - Optional tab, only visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible10 KB (795 words) - 09:23, 2 February 2024
- Solids Recovery Unit (section EB (Evaluation Block))relating to the unit including Evaluation Block settings. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled on15 KB (1,739 words) - 09:31, 2 February 2024
- Batch Centrifuge (section EB (Flow Evaluation Block))general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On is enabled on the first tab. MU - Optional tab, or multiple11 KB (789 words) - 04:10, 21 February 2024
- Hot Flash Tie (section EB (Flow Evaluation Block))unit. PC - Optional tab, only visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible9 KB (844 words) - 09:34, 2 February 2024
- Screen 2 (section Data Sections)Reactions are enabled in the Evaluation Block. EHX - Optional tab, only visible if the EnvironHX is enabled in the Evaluation Block. Evap - Optional tab20 KB (2,817 words) - 05:37, 14 May 2024
- Potash Solubility (section Data Sections)solubility data from Perry (ref. 3) - therefore ignore any other species in solution and use data for 'pure' CaSO4; or Use solubility data from d'Ans (Ref27 KB (1,563 words) - 10:16, 1 February 2024
- Multi-Stage Counter Flow Tie (section Data Sections)Absorbers, Kilns, Scrubbers, etc. Each stage in the model has an Evaluation Blocks (EB), and hence the user may enable Reactions (RB), Vapour-Liquid Equilibrium14 KB (1,055 words) - 09:23, 2 February 2024
- Reaction Block is part of an Evaluation Block (EB) then the user may use the 'On-AutoSequence' option or change the evaluation sequence relative to other26 KB (2,722 words) - 03:26, 5 April 2024
- Model Procedures (section Data Sections)e. if it is used in the function MP_Eval_BeforeEB(), then it may be stream feeding into the Evaluation Block; or An indeterminate value. Therefore, please20 KB (1,014 words) - 01:44, 6 September 2023
- PHREEQC Reactor (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.7 KB (1,742 words) - 04:05, 28 March 2024
- PHREEQC Reverse Osmosis Unit (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.11 KB (2,072 words) - 04:02, 28 March 2024
- OLI Reactor 2 (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.8 KB (1,721 words) - 02:49, 14 March 2024
- PHREEQC Pond Model (section Data Sections)ShowBed are enabled on the first tab page. Contains data on the material in the bed. Content tab - contains data on the material in the pond. Preset tab - Optional114 bytes (1,749 words) - 13:23, 6 March 2024
- AQSol Reverse Osmosis Unit (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.11 KB (2,040 words) - 08:18, 14 March 2024
- for edge case where tag is not selected in Model Data Transfer dialog when using context menu option "Data Transfer" from Access window tag. Size Distribution114 KB (16,094 words) - 02:05, 24 April 2024
- OLI Pond Model (section Data Sections)ShowBed are enabled on the first tab page. Contains data on the material in the bed. Content tab - contains data on the material in the pond. Preset tab - Optional89 bytes (1,775 words) - 11:47, 21 February 2024
- OLI Reverse Osmosis Unit (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.11 KB (2,080 words) - 08:25, 14 March 2024
- Flash Tank 2 in Dynamic Mode (section Data Section)consists of several sections: FlashTank2 tab. This section contains the variables that will be visible in dynamic mode. Cont tab. This section allows the user14 KB (448 words) - 16:44, 2 August 2023
- AQSol Reactor (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.8 KB (1,708 words) - 03:16, 14 March 2024
- ChemApp Reactor (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.7 KB (1,571 words) - 02:02, 13 March 2024
- Thickener 2 (section Data Sections)unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible23 KB (1,249 words) - 09:23, 2 February 2024
- option for Recirculation of Liquor. New data type Memo implemented. (See Data Types for more information) Alternate data type declarations available: Integer13 KB (2,038 words) - 19:09, 2 August 2023
- Navigation: Models ➔ General Models ➔ Tank ➔ Dynamic Mode ➔ Optional Data Sections This page is only visible if the Level Lookup option is chosen. Notes:8 KB (263 words) - 02:25, 28 August 2023
- Basic Pond Model (section Data Sections)enabled on the first tab page. Contains data on the material in the clarified liquor layer. Content tab - contains data on the material in the pond. Preset5 KB (614 words) - 13:12, 9 February 2024
- Heap Leach (section Data Sections)a single stream. This is before any Evaluation Block (RB, EHX, MU) models are evaluated. LXXX tab - contains data on the solids and liquids content in44 KB (1,891 words) - 03:59, 14 May 2024
- database and replace it with the default SysCAD data. You may choose to overwrite the default data with your own data after the upgrade step. ALL SysCAD 9.2 databases25 KB (4,079 words) - 10:09, 3 August 2023
- enhancements compared to the Flash Tank model such as: It has an Evaluation Block (EB), which allows Phase Change (PC) functionality such as Solubility16 KB (2,427 words) - 10:14, 1 February 2024
- SSA Quality management. Importantly SSA.SetData as a user option has been removed, instead to change SSA data, user must select the "Modify" option for57 KB (9,089 words) - 09:50, 11 March 2024