Met Dynamics - Crusher
Navigation: Models ➔ Met Dynamics Models ➔ Met Dynamics - Crusher
Latest SysCAD Version: 25 October 2024 - SysCAD 9.3 Build 139.36522
Related Links:
Available from Build 139.35544.
General Description
This model implements fixed or predictive comminution. The model can handle multiple ore streams with common or different parameters. The user can select one of the following methods:
- User defined fixed discharge partition curve
- Whiten Crusher
Requires Met Dynamics Add-On and license from Met Dynamics.
Diagram
The diagram shows the default drawing of the Crusher, with all of the streams that must be connected to the unit.
The physical location of the streams connecting to the Crusher is unimportant. The user may connect the streams to any position on the unit.
Inputs and Outputs
Label | Required Optional |
Input Output |
Number of Connections | Description | |
Min | Max | ||||
Feed | Required | In | 1 | 10 | The feed/s to the unit |
Product | Required | Out | 1 | 1 | The product from the unit |
Model Theory and Data Sections
Please refer to Met Dynamics Wiki for further information.
Adding this Model to a Project
Add to Configuration File
Sort either by DLL or Group:
DLL: | MetDynamics.dll |
→ | Units/Links | → | Met Dynamics: Crusher | |
or | Group: | Size Distribution |
→ | Units/Links | → | Met Dynamics: Crusher |
See Model Selection for more information on adding models to the configuration file.
Insert into Project Flowsheet
Insert Unit | → | Met Dynamics | → | Crusher |
See Insert Unit for general information on inserting units.