- Controlled and Referenced Variables (category User Interface)controlled will have a coloured arrow indicating this fact to the user. In addition to this, the user may right click on the tag and a menu will be visible with7 KB (855 words) - 02:06, 15 June 2021
- Viscosity is Ns/m² User can use a number formats for entering viscosity data into the SysCAD database: Constant - User can enter a constant value Equations for11 KB (838 words) - 02:14, 9 November 2023
- [math]\displaystyle{ S =\matrix{H_2 \\ CH_4\\ O_2\\ H_2O\\ CO\\ CO_2\\} \pmatrix{ 0 & 0 & 2 \\ 0 & 1 & 4 \\ 2 & 0 & 0 \\ 1 & 0 & 2 \\ 1 & 1 & 0 \\ 2 & 1 & 0 \\} \quad29 KB (4,645 words) - 23:31, 14 February 2024
- Navigation: User Guide ➔ COM Automation ➔ Testing if SysCAD is Open in VBA Generally a COM Automation macro is written to start SysCAD, load a project4 KB (564 words) - 09:40, 9 February 2022
- Navigation: User Guide ➔ Mass and Energy Balance SysCAD will always try to maintain a mass and energy balance. For information on how SysCAD calculates7 KB (982 words) - 02:06, 15 June 2021
- Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Database Access Manually entering a lot of data into the database can be tedious2 KB (315 words) - 18:57, 1 September 2022
- stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator9 KB (2,284 words) - 17:40, 21 June 2024
- -rr[:, 0]**2/rr[:, 1] ## Affinity DeltaN2O4 = -np.diff(rp[:, 1]) ## Change in [N2O4] N2O4Term = k*(rp[:-1, 1]+rp[1:, 1])/2. ## Average value of [N2O4] in each4 KB (600 words) - 18:44, 1 September 2022
- stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator9 KB (2,350 words) - 15:55, 21 June 2024
- set nFC = -2, nC = 2 : [math]\displaystyle{ \left(\cfrac{A_o - A^*}{F}\right)^2=\left(\cfrac{A_o - A^*}{C}\right)^2 \times \cfrac{C^2}{F^2} }[/math] SAL33 KB (3,902 words) - 23:27, 22 February 2024
- stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator9 KB (2,327 words) - 17:28, 21 June 2024
- BaseFilesUser\Symbols folder. The purpose of the ..SysCADxxx\BaseFilesUser\Symbols folder is for user defined symbols. For example, if the user creates19 KB (2,757 words) - 22:44, 12 May 2024
- converged. Recycle Between Ties 1 0 1.0 2 0.5 1.5 3 0.75 1.75 4 0.875 1.875 5 0.9325 1.9325 .... 18 0.99999905 2 SysCAD has an implementation of the method16 KB (2,589 words) - 08:08, 24 November 2023
- Upgrade to SysCAD 9.2 (section Installing SysCAD 9.2)to SysCAD 9.2. For a full list of differences between SysCAD 9.1 and SysCAD 9.2, please refer to SysCAD 9.2 Release Notes. Install SysCAD 9.2. This should25 KB (4,079 words) - 10:09, 3 August 2023
- Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Optimisation Related Links: Example Project - ChemApp with Python Optimisation9 KB (842 words) - 09:06, 3 November 2022
- 75694246e+02, 1.76991503e+02, 2.72699554e+01, 1.28469206e+01, 6.32469251e-01, 2.60232738e+00, 5.87385513e-01, 1.45618792e+01, 5.32841733e-02, 2.42947148e+01, 4.20754018e-02])6 KB (857 words) - 04:19, 25 September 2023
- configuration file. In Step 2 of 2, select the Calculations tab Follow instructions given in Calculation Configuration User can add customised species calculation14 KB (1,835 words) - 03:18, 5 April 2024
- Similarly, if T2 > TUpper Limit then: [math]\displaystyle{ \Delta H _{T_{upperlimit} \quad \; \to \; T_2} \; = Cp_{T_{upperlimit}} \quad *\left ( T_2 - T_{upperlimit}25 KB (1,870 words) - 09:58, 1 February 2024
- TagValue("FEED_ppm_SET.TC[1].User.Value")) ## Print another tag print ("Changing value to 45 ppm") Tags.SetTagValue("FEED_ppm_SET.TC[1].User.Value", 45) ## Change11 KB (1,558 words) - 18:42, 2 August 2023
- Scenarios (category User Interface)model is to be used for scenario testing, it is recommended to save a scenario file for each test case performed, so that user can quickly recall the scenario8 KB (1,164 words) - 05:40, 5 September 2023