Explorer Window: Difference between revisions

From SysCAD Documentation
Jump to navigation Jump to search
Line 40: Line 40:
== Navigating to Existing Graphics and Trend Windows ==
== Navigating to Existing Graphics and Trend Windows ==


The user may navigate to any Graphics or Trend window in the project by simply clicking on the required window in the Explorer window.  SysCAD will activate the required window.  This is a really useful feature for a large project that contains many Graphics and / or Trend windows.
The user may navigate to any Graphics or Trend window in the project by simply clicking on the required window in the Explorer window.  SysCAD will activate the required window.


The windows are listed alphabetically in the Explorer window, as shown above.  This is why it is often a good idea to number the flowsheets so that they follow the process flow, for example:
If the user has added Areas to the project, then the flowsheets may be grouped by area.  This is a really useful feature for a large project that contains many Graphics windows.
 
The Graphics windows are listed alphabetically in the Explorer window, as shown in the left hand window above.  This is why it is often a good idea to number the flowsheets so that they follow the process flow, for example:
* 01 Crushing and Screening
* 01 Crushing and Screening
* 02 Milling and Cycloning
* 02 Milling and Cycloning
* 03 Leaching
* 03 Leaching
* 04 Counter Current Washing Circuit, etc.
* 04 Counter Current Washing Circuit, etc.
If the user has added Areas to the project, these will also be listed alphabetically, so again it is recommended that the areas are alphanumeric and follow the flow of the project, e.g:
* 0100_FeedPrep
* 0200_Copper
* 0300_Nickel, etc.


The Graphics windows are all listed first, followed by the Trend windows.
The Graphics windows are all listed first, followed by the Trend windows.

Revision as of 08:43, 24 October 2017

Navigation: User Guide -> Windows -> Explorer Window

This page is for SysCAD 9.3 Build 137 or later. For earlier builds, including SysCAD 9.3 Build 136 and SysCAD 9.2, please see Explorer Window 9.3.

Introduction

The SysCAD Explorer Window may be accessed in any of the following ways:

Command Button ExplorerButton.png    
Command Path View - Explorer OR Window - Select Window
Short Cut Key Ctrl+E OR Ctrl+W


This window contains information regarding the Graphics and Trend windows available in the project, as well as the units on each graphic.

The Explorer window is not constrained within the boundaries of the SysCAD window and may be moved beyond the SysCAD limits, and if the user has dual monitors (highly recommended) this window may be located on the alternate monitor.

This is a very useful feature, as the Explorer window in always on top and by moving it away from the SysCAD window you free up more space to view the actual project.

Flowsheets grouped in Areas

The Explorer Window is very useful when navigating a large project with multiple flowsheets. In addition to displaying all of the flowsheets, and Trends, in the project, the user may group the flowsheets into Areas on the Plant Model Flowsheets tab and this helps with the navigation.

The image below shows the same project with 12 flowsheets. The left window has all of the flowsheets in a single default Area, while the window on the right has flowsheets group by area:

Explorer Window 4.png

Notes

  1. The Explorer default behaviour can be found on Tools | General Options | Global.
  2. Graphics and Trend information are always available;
  3. Classes information are shown by default as the explorer window is accessed. The user can right click to on this and choose hide to remove the information.
  4. Nodes, Tears and Flows (Flows are only available for dynamic projects) information will be Off by default. The user may right click on the group and choose Show.

Navigating to Existing Graphics and Trend Windows

The user may navigate to any Graphics or Trend window in the project by simply clicking on the required window in the Explorer window. SysCAD will activate the required window.

If the user has added Areas to the project, then the flowsheets may be grouped by area. This is a really useful feature for a large project that contains many Graphics windows.

The Graphics windows are listed alphabetically in the Explorer window, as shown in the left hand window above. This is why it is often a good idea to number the flowsheets so that they follow the process flow, for example:

  • 01 Crushing and Screening
  • 02 Milling and Cycloning
  • 03 Leaching
  • 04 Counter Current Washing Circuit, etc.

If the user has added Areas to the project, these will also be listed alphabetically, so again it is recommended that the areas are alphanumeric and follow the flow of the project, e.g:

  • 0100_FeedPrep
  • 0200_Copper
  • 0300_Nickel, etc.

The Graphics windows are all listed first, followed by the Trend windows.

Manipulating Graphics Windows (Flowsheets)

Overall Graphics Commands

By right clicking on 'Graphics' in the Explorer window the user will see the following pop up menu:

Explorer Window Graphics.png

This allows the user to carry out a number of actions:

  1. New Graphics Window allows the user to open a new flowsheet window.
  2. Bulk Tag Change opens the Bulk Tag change dialogue box, allowing the user to change a number of tags easily.
  3. Colour Scheme allows the user to change the overall colour scheme of all flowsheets.
  4. Window Behaviour allows the user to specify if graphics windows are sized, moved or displayed individually or together.
  5. Copy Graphic List to Clipboard allows the user to paste a list of the graphics (flowsheet names) into another application, e.g. Excel, Word, etc.
  6. Copy Graphic, Tag List to Clipboard allows the user to paste a list of the graphics (flowsheet names) with all of the unit tags into another application, e.g. Excel, Word, etc.

Individual Flowsheets

By right clicking on a Flowsheet name in the Explorer window the user will see the following pop up menu:

This allows the user to carry out a number of actions on the flowsheet:

Explorer Window2.png
  1. The user can Activate or Deactivate the selected flowsheet by clicking on the 'Active' command (See also Active Pages).
  2. The user may rename the selected flowsheet (if a Trend window is selected, the user may also rename it using this command).
  3. The user may use the 'Bulk Tag Change' command to change a number of Tags on the selected flowsheet. See Bulk Change Tag
  4. The user may copy the bitmap of the selected flowsheet to be used in an external application, such as an Excel report or a word document.
    Please note that the Heading text that appears on the flowsheet may be changed by going to Tools - General Options - Graphics Tab
  5. The user may copy the Tag list of the selected flowsheet. The list of tags will depend on the Filter selection (at the bottom of the Explorer window). In the example shown above, the Tag List this will contain the tags of ALL units on the selected flowsheet because the filter has not been enabled.
  6. The user may Delete the flowsheet (deletes all the models on the graphics page)
  7. The user may close the flowsheet (NOT recommended). Any closed graphics pages are NOT saved, this could lead to missing graphics page and orphan models.
  8. The user may Reset values for the individual flowsheet - this sets all flows to zero and clears any calculated values for the models. When the user presses the Solve button, the flowsheet will be forced to re-solve. Please also see Action Commands - Reset.
  9. The user may remove any Qualities, size data, lockups, etc, from the flowsheet. This only removes any Quality that has built up in the flowsheet.

Navigating to Unit models or Pipes

The user may navigate to any unit model or pipe in the project by expanding the tree view and then clicking on the required unit or pipe in the Explorer window.

This is shown in the image below (this is for a small project with only a single Graphics page - so that it is easier to view the units)

Explorer Window4.png

Creating Equipment or Pipe List

The user may limit the units that are displayed by using the Filter at the bottom of the Explorer Window.

For example, if the user wishes to copy the pipes on a single graphics page, and the pipes all have the naming convention P_nnn, then in the filter window type P_.

The following view is shown:

Explorer Window 5.png


The user may then copy all of the pipe tags on Graphics Window 05_Flowsheet to another application, such as Excel to form the basis of a report, see Excel Reports .

Models Marked with Red Cross

The model listing behaviour has changed in SysCAD 9.2 Build 135.14291. In this build (or later), only missing models will be marked with red cross.

A Missing Model refers to a SysCAD unit model that's been deleted, but the Graphics still exist.

This could be a result from the following actions:

  • A SysCAD unit model/graphics page has been deleted
  • User closes graphics page without saving
  • User then saves the project. (Closed graphics page will NOT be saved)
  • User then closes and opens the project, and reopens the graphics page (that was not saved).

As a result, the model has been deleted from the database but the graphics file has not been updated, thus causing the mismatch.

The easiest way to check for missing models is by looking at the Graphics page directly (not from Explorer). If miss model exists, the models would appear grey and there is no access window when you click on them.

The recommended action for Missing Model with graphics is to delete all the dummy graphics using Graphics - Delete, then re-build the flowsheet.


For SysCAD builds SysCAD 9.2 Build 135.14290 or earlier, two other types of Tags may appear with "red crosses" next to them. These inlcude:

  1. Tear Flange (usually contain “ <>” or “Flng” in the Tag) - Please NOTE that these only appear in the explorer if the Tear (group) is hidden.
  2. Direct Links / Makeup streams

These Red Crosses means SysCAD can’t create a hot jump to Tear / Direct Link directly from the Explorer window, it does NOT mean the model is missing. So while checking for missing models please ignore these tags.

Explorer9.png

This problem has been rectified in SysCAD 9.2 Build 135.14291.

Missing Graphics

It is possible to get into a situation where "orphan" models without Graphics Representation exist in the SysCAD project.

The missing Graphics could be due to user accidentally closing the Graphics Page, or Graphics Symbol got "corrupted" and has gone missing, thus creating "orphan" models without graphics representation.

  1. If the models are valid and must exist, then the graphic symbols should be added back to the project.
    • In the case of missing an entire page: try and located the missing graphic page from previously saved versions, copy back into the project and open it using Open file: "xxxx.scg"
    • In the case of missing single Graphics Symbol:
  2. If the Orphan models in the project are NOT required, then user can delete these orphan models using the Explorer Window:
    • From the section called Missing Graphics under the graphics tree, open that tree to get a list of all the unit operations in the project without graphics.
      MissingGraphics1.png
    • If user wish to delete all the orphan models, simply right click on the word Missing Graphics to bring up a popup menu, select the option to Delete all nodes without graphics.
  3. Once that is done, save the project, close and reopen Explorer to refresh the explorer list. User should find that the missing graphics is fixed.