Met Dynamics - Classifier
Navigation: Models ➔ Met Dynamics Models ➔ Met Dynamics - Classifier
Latest SysCAD Version: 25 October 2024 - SysCAD 9.3 Build 139.36522
Related Links:
Available from Build 139.35544.
General Description
The Classifier mixes perfectly all the incoming feed streams and then, based on the user configuration, calculates the amount, temperature and composition of material reporting to the products. The solid splits are based on the feed size distribution/s and one of the following methods:
- User defined partition curve
- Reid-Plitt partition curve
- Whiten-Beta partition curve
- Plitt-Flintoff gravity classification model
Requires Met Dynamics Add-On and license from Met Dynamics.
Diagram
The diagram shows the default drawing of the Classifier, with all of the streams that are required for operation of the unit.
The physical location of the streams connecting to the Classifier is unimportant. The user may connect the streams to any position on the unit.
Inputs and Outputs
Label | Required Optional |
Input Output |
Number of Connections | Description | |
Min | Max | ||||
Feed | Required | In | 1 | 10 | The slurry feed/s to the unit |
OverFlow | Required | Out | 1 | 1 | The over flow from the unit |
UnderFlow | Required | Out | 1 | 1 | The under flow from the unit |
Model Theory and Data Sections
Please refer to following Met Dynamics wiki pages for further information:
Adding this Model to a Project
Add to Configuration File
Sort either by DLL or Group:
DLL: | MetDynamics.dll |
→ | Units/Links | → | Met Dynamics: Classifier | |
or | Group: | Size Distribution |
→ | Units/Links | → | Met Dynamics: Classifier |
See Model Selection for more information on adding models to the configuration file.
Insert into Project Flowsheet
Insert Unit | → | Met Dynamics | → | Classifier |
See Insert Unit for general information on inserting units.