Template:DSp Data Section
Jump to navigation
Jump to search
Tag (Long/Short) | Option | Description |
Content (Tag Display and Flow Basis) | ||
SpeciesTag | The Species Long / short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names. See Species Long/short Example for more information. | |
SpBasis | All | The total mass or moles of the stream will be used when calculating fractional values. |
Phase | The mass or moles of each phase (solid, liquid or gas) will be used when calculating fractional values. | |
Individual Phase | The mass or moles of each Individual phase (solid, liquid, aqueous, organic, gas, etc.) will be used when calculating fractional values. | |
Species View Options | ||
Mass Flow | Mass Flow Rate of the species, phase or total. | This mode will overwrite the QmReqd configured on the first page. The total flow rate delivered by the feeder will be the sum of all the species flow rates. |
Mass Frac | Mass Fraction of the species or phase. | The total flow rate delivered by the feeder will be based on the QmReqd configured on the first page. The total fractions will always add to 100%. |
Mole Flow | Mole Flow Rate of the species, phase or total. | This mode will overwrite the QmReqd configured on the first page. The total flow rate delivered by the feeder will be the sum of all the species flow rates. |
Mole Frac | Mole Fraction of the species or phase. | The total flow rate delivered by the feeder will be based on the QmReqd configured on the first page. The total fractions will always add to 100%. |
============== Totals | ||
Total | Calculated [c] | The total value for the chosen view. For fraction views, the total fractions will always add to 100%. |
Solids | Input or Calculated [c] | This is the total for the solid phase occurrence. For the FeederSink unit, if the Feeder Operation Selection allows solids, then this field may be set by the user or default to 100%. |
Liquids | Input or Calculated [c] | This is the total for the liquid phase occurrence. For the FeederSink unit, if the Feeder Operation Selection allows liquids, then this field maybe set by the user or default to 100%. |
Vapours | Input or Calculated [c] | This is the total for the vapour phase occurrence. For the FeederSink unit, if the Feeder Operation Selection allows vapours, then this field maybe set by the user or default to 100%. |
Individual phase X | Input or Calculated [c] | If the Individual Phase basis is chosen, then additional fields will appear for the flow or fraction of each individual phase total. The individual phase is defined in the SysCAD database, see Species Definition |
============== Phase / Individual Phase (Species layout is set in the cfg file.) | ||
Species X | Input | User can enter the composition of each species for the chosen view. |
Species Calculation X | Calculated [c] | Any user defined Species Calculations maybe visible here. |
Example:
We are given an ore analysis on a dry mass basis with a moisture content of 5% by mass.
| ||
Global Material View Options | ||
ImageColumnCount | The default number of columns displayed on the DSp (Define Species Flow) tab is 2. However, the user may change the number of columns displayed by changing this value, the maximum is 4. This can also be changed on the Views Tab of the Plant Model, hot jump is provided by the next variable below. | |
ViewOptions | Use the magnifying glass hot jump to go to the Views Tab | |
FixUpStrategy | Only relevant if the Mass Frac or Mole Frac View options are chosen. Allows SysCAD to 'fix' the stream make up to 100% if the sum of the numbers entered is less than or greater than 100%. | |
Largest | SysCAD will increase or decrease the fraction of the species with the largest unmodified fraction.
| |
BottomUp | SysCAD will increase or decrease the fraction of the species which is at the bottom (last) of the list of species.
|