Change Sieve Series: Difference between revisions

From SysCAD Documentation
Jump to navigation Jump to search
Line 17: Line 17:
== Inputs and Outputs ==
== Inputs and Outputs ==


{| border="1" cellpadding="5" cellspacing="0"  
{| border="1" cellpadding="5" cellspacing="0"
|-
| valign="top" rowspan="2" | '''Label''' || valign="top" rowspan="2" | '''Required<br>Optional''' || valign="top" rowspan="2" | '''Input<br>Output ''' ||  colspan="2"  | '''Number of Connections''' || valign="top" rowspan="2" | '''Description'''
|-
|  '''Min''' || '''Max. '''
|-
|-
! Label !! Input / Output
| Input || Required || In || 1 || 1 || Input stream to Change Sieve Series.
! colspan="2" align="center" | No. of Connections
! Description
|-
|-
! &nbsp;!! &nbsp;!! Min !! Max. !!&nbsp;
| Output || Required || Out || 1 || 1 || Output stream from Change Sieve Series.
|-
| Input || In || 1 || 1 || Input stream to Change Sieve Series.
|-
| Output || Out || 1 || 1 || Output stream from Change Sieve Series.
|}
|}


== Model Theory ==
== Model Theory ==

Revision as of 06:13, 30 October 2012

Navigation: Main Page -> Models -> Size Distribution Models


General Description

The Change Sieve Series model is required when a different size distribution (or sieve series) is to be used. This is particularly important when adding streams with different sieve series, as only streams with the same sieve series can be added. Therefore, before the streams can be mixed properly, the change sieve series model must be put in place.

To see more information on size distributions, please see Size Distribution (PSD).

Diagram

Models-change-Sieve-Series-image001.gif

The diagram shows two streams using different sieve series mixing. A Change Sieve Series model is used to change the Coarse Sieve series to Fine Sieve Series before the mixing can correctly occur.

Inputs and Outputs

Label Required
Optional
Input
Output
Number of Connections Description
Min Max.
Input Required In 1 1 Input stream to Change Sieve Series.
Output Required Out 1 1 Output stream from Change Sieve Series.

Model Theory

To convert from sieve series A to sieve series B:

  • For size interval in sieve series A the Sieve Changing model converts the % passing data to the Rosin-Rammler variable;
  • The model then performs an interpolation to obtain the required Rosin-Rammler variable at the required size interval in sieve series B;
  • This is then converted to % passing for sieve series B.

Data Sections

The default sections and variable names are described in detail in the following table.

Tag / Symbol Input / Calc Description

Common First Data Section

 

 

On Tick Box The toggle the sieve changing operation on/off.
SizeDefn List Box Lists all the available sieve series


Adding this Model to a Project

Insert into Configuration file

Sort either by DLL or Group.

 

DLL:

Commn1.dll

Units/Links

Size Alteration: Change Sieve Series

OR

Group:

Size Distribution

Units/Links

Size Alteration: Change Sieve Series

See Project Configuration for more information on adding models to the configuration file.

Insert into Project

 

Insert Unit

Size Alteration

Change Sieve Series

See Insert Unit for general information on inserting units.