The default access window consists of a number of sections,  
The default access window consists of a number of sections,  
# The first tab has the same name as the model tag, contains the main configuration information relating to the unit.
# '''[[#Tank Page|Tank-1]]''' tab - Contains general information relating to the unit.
# Optional tab [[Vapour Liquid Equilibrium (VLE)]]
# '''[[VLE]]''' - Optional tab, only visible if the VLEquilibrium is enabled in the Evaluation Block.
# The section, Info, fully described in [[Common Data Sections#Common Data on Info Tab Page|Info Tab Page]] Section.
# '''[[Common Data Sections#Common Data on Info Tab Page|Info]]''' tab - Contains general settings for the unit and allows the user to include documentation about the unit and create Hyperlinks to external documents.
# The section, Links, only visible in SysCAD 9.2, contains a summary table for all the input and output streams.  See [[Links Table]].
# '''[[Links Table|Links]]''' tab, only visible in SysCAD 9.2, contains a summary table for all the input and output streams.  
# The last section is the [[Audit]]. See [[Model Examples]] for enthalpy calculation Examples.
# '''[[Audit]]''' tab - Contains summary information required for Mass and Energy balance. See [[Model Examples]] for enthalpy calculation Examples.
 





Revision as of 06:26, 30 October 2012

Navigation: Main Page -> Models -> Pressure Changing Models

To Be Completed....


General Description

The valve model will add pressure drop to the stream or operates at a specified pressure.

Diagram

Valve image001.gif

The diagram shows the default drawing of the Valve, with the required connecting streams. The unit will not operate unless all of the above streams are connected.

The physical location of the connections is not important; the user may connect the streams to any position on the drawing.

Inputs and Outputs

Label Required
Optional
Input
Output
Number of Connections Description
Min Max.
Input Required In 1 1 Input stream to valve.
Output Required Out 1 1 Output stream from valve.

Model Theory

The valve is a constant enthalpy process.

Step 1) Enthalpy can be calculated from the inlet conditions.

Step 2) Outlet temperature can be calculated from enthalpy and outlet pressure.

Data Sections

The default access window consists of a number of sections,

  1. Tank-1 tab - Contains general information relating to the unit.
  2. VLE - Optional tab, only visible if the VLEquilibrium is enabled in the Evaluation Block.
  3. Info tab - Contains general settings for the unit and allows the user to include documentation about the unit and create Hyperlinks to external documents.
  4. Links tab, only visible in SysCAD 9.2, contains a summary table for all the input and output streams.
  5. Audit tab - Contains summary information required for Mass and Energy balance. See Model Examples for enthalpy calculation Examples.


Tag / Symbol
Input / Calc
Options
Description/Calculated Variables

Common First Data Section

Requirements

PressureMethod

List Box

None

No pressure change across the unit.

Drop

The user specifies a pressure drop. Therefore, Pout = Pin - Pdrop

Fixed

The user specifies a fixed outlet pressure from the unit.

Atmos

The outlet pressure from the unit is set to atmospheric pressure.

PDrop

Input

 

The required pressure drop. Visible if the Drop method is selected.

PRqd

Input

 

The required outlet pressure. Visible if the Fixed method is selected.

VLEquilibrium

List Box

Off

Vapour Liquid Equilibrium is off.

On

Vapour Liquid Equilibrium (VLE) is enabled. The associated section, VLE becomes visible and may be configured.
Note: This option may automatically adjust the species make-up in Qo.

Results

Qm

Calc

 

The mass flow rate through the unit.

Ti

Calc

 

The inlet temperature to the unit.

To

Calc

 

The outlet temperature from the unit.

Pi

Calc

 

The inlet pressure to the unit.

dP

Calc

 

The pressure change across the unit.

Po

Calc

 

The outlet pressure from the unit.

Vfi

Calc

 

The Inlet vapour fraction.

Vfo

Calc

 

The outlet vapour fraction.

Adding this Model to a Project

Insert into Configuration file

Sort either by DLL or Group.

 

DLL:

Basic1.dll

Units/Links

Process: Piping: Valve - Non-Return(1)

or

Group:

Mass Transfer

Units/Links

Process: Piping: Valve - Non-Return(1)

See Project Configuration for more information on adding models to the configuration file.


Insert into Project

 

Insert Unit

Process

Piping

Valve - Non-Return(1)

See Insert Unit for general information on inserting units.