- [math]\displaystyle{ \beta_{ij,T} \propto \frac {S_{ij}^2}{S_j}.\left( 1-\frac {S_{ij}^2}{D_{max}^2} \right) }[/math] Where: [math]\displaystyle{ S_{ij} }[/math]39 KB (5,250 words) - 18:32, 2 August 2023
- compounds would act in the same way. This should be reviewed based on real test data. Reagent concentrations, ratios and excesses were often assumed and6 KB (1,011 words) - 04:03, 8 September 2023
- constants in the Rosenberg-Healy equation may be specified by the user by selecting the RosenbergUser option: [math]\displaystyle{ \alpha_0 }[/math] = ASat.a0 etc19 KB (552 words) - 14:10, 14 March 2024
- SysCAD 9.2, What's New, Revision History The formal release date for SysCAD 9.2 Build 131.6369 is 30th July 2009. Since this release, SysCAD 9.2 Build 13219 KB (3,031 words) - 09:50, 11 March 2024
- heat absorbed by the surrounding air, thus: (2) [math]\displaystyle{ \cfrac{L}{G} = \cfrac{h_2-h_1}{C(T_1-T_2)} }[/math] where: G = air loading, mass flow19 KB (1,556 words) - 04:18, 21 February 2024
- Navigation: User Guide ➔ View ➔ Plant Model ➔ States ➔ Full Detail Related Links: Plant Model - States This page describes the extension of the States7 KB (61 words) - 09:55, 23 March 2023
- Build 138 Release Notes Full (section User interface)method to allow user to selectively define which species is included in the elemental concentration count. For example, user can select Fe2+ only, not total19 KB (2,881 words) - 18:38, 2 August 2023
- cases without further user input. As is, this file is used to test the sensitivities of TWO variables. User can define the test value range for the two5 KB (685 words) - 10:14, 6 September 2021
- (partial) Tag,Value SLURRY_IN.QmReqd (t/h),40 Feed_ppm_Set.TC[1].User.Value,40 Feed_ppm_Set.TC[2].User.Value,500 SLURRY_IN.Content.DLockup.[Au(s)].LockupReqd (%)10 KB (1,420 words) - 06:53, 19 February 2024
- dKernel tab only shown when Agglom.Kernel.Type = User or Kernel Builder. With Agglom.Kernel.Type = User, [math]\displaystyle{ \beta }[/math] values are68 KB (396 words) - 01:37, 22 November 2023
- unit tag names. New BaseFilesUser folder, along side BaseFiles folder, for all global user settings, user Symbols and user engineering conversions. BaseFiles16 KB (2,427 words) - 10:14, 1 February 2024
- the user to specify a single heat loss factor. User can choose reference temperature to be the feed or product temperature. SuperHeat Loss : User can lose42 KB (6,030 words) - 18:10, 2 August 2023
- Notes The user MUST have added and configured a PHREEQC Model Configuration unit in the SysCAD project before this unit can function. The user MUST have9 KB (1,955 words) - 06:51, 14 June 2024
- CoO.Al2O3 132.0 132.2 0.174 0.75 ....... Fe2S3 117.9 47.8 59.468 0.57 Na2C2O4 132.0 34.0 74.248 0.99 2CaO.[Al2O3].8SiO2 567.1 97.7 82.781 0.82 CrO2 52.736 KB (1,198 words) - 09:46, 21 July 2023
- Navigation: Models ➔ Control 2 Models ➔ Transmitter The transmitter is used to pass a value to a PID block. Its use is not required since a PID can access11 KB (341 words) - 11:45, 21 February 2024
- Navigation: Models ➔ Control 2 Models ➔ Actuator The Actuator is used to get a value from a PID block and then change the value of a tag in the model.5 KB (204 words) - 11:45, 21 February 2024