Search results

Jump to navigation Jump to search
  • [math]\displaystyle{ \beta_{ij,T} \propto \frac {S_{ij}^2}{S_j}.\left( 1-\frac {S_{ij}^2}{D_{max}^2} \right) }[/math] Where: [math]\displaystyle{ S_{ij} }[/math]
    39 KB (5,250 words) - 18:32, 2 August 2023
  • compounds would act in the same way. This should be reviewed based on real test data. Reagent concentrations, ratios and excesses were often assumed and
    6 KB (1,011 words) - 04:03, 8 September 2023
  • constants in the Rosenberg-Healy equation may be specified by the user by selecting the RosenbergUser option: [math]\displaystyle{ \alpha_0 }[/math] = ASat.a0 etc
    19 KB (552 words) - 14:10, 14 March 2024
  • SysCAD 9.2, What's New, Revision History The formal release date for SysCAD 9.2 Build 131.6369 is 30th July 2009. Since this release, SysCAD 9.2 Build 132
    19 KB (3,031 words) - 09:50, 11 March 2024
  • heat absorbed by the surrounding air, thus: (2) [math]\displaystyle{ \cfrac{L}{G} = \cfrac{h_2-h_1}{C(T_1-T_2)} }[/math] where: G = air loading, mass flow
    19 KB (1,556 words) - 04:18, 21 February 2024
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ States ➔ Full Detail Related Links: Plant Model - States This page describes the extension of the States
    7 KB (61 words) - 09:55, 23 March 2023
  • method to allow user to selectively define which species is included in the elemental concentration count. For example, user can select Fe2+ only, not total
    19 KB (2,881 words) - 18:38, 2 August 2023
  • cases without further user input. As is, this file is used to test the sensitivities of TWO variables. User can define the test value range for the two
    5 KB (685 words) - 10:14, 6 September 2021
  • (partial) Tag,Value SLURRY_IN.QmReqd (t/h),40 Feed_ppm_Set.TC[1].User.Value,40 Feed_ppm_Set.TC[2].User.Value,500 SLURRY_IN.Content.DLockup.[Au(s)].LockupReqd (%)
    10 KB (1,420 words) - 06:53, 19 February 2024
  • dKernel tab only shown when Agglom.Kernel.Type = User or Kernel Builder. With Agglom.Kernel.Type = User, [math]\displaystyle{ \beta }[/math] values are
    68 KB (396 words) - 01:37, 22 November 2023
  • unit tag names. New BaseFilesUser folder, along side BaseFiles folder, for all global user settings, user Symbols and user engineering conversions. BaseFiles
    16 KB (2,427 words) - 10:14, 1 February 2024
  • the user to specify a single heat loss factor. User can choose reference temperature to be the feed or product temperature. SuperHeat Loss : User can lose
    42 KB (6,030 words) - 18:10, 2 August 2023
  • Notes The user MUST have added and configured a PHREEQC Model Configuration unit in the SysCAD project before this unit can function. The user MUST have
    9 KB (1,955 words) - 06:51, 14 June 2024
  • CoO.Al2O3 132.0 132.2 0.174 0.75 ....... Fe2S3 117.9 47.8 59.468 0.57 Na2C2O4 132.0 34.0 74.248 0.99 2CaO.[Al2O3].8SiO2 567.1 97.7 82.781 0.82 CrO2 52.7
    36 KB (1,198 words) - 09:46, 21 July 2023
  • Navigation: Models ➔ Control 2 Models ➔ Transmitter The transmitter is used to pass a value to a PID block. Its use is not required since a PID can access
    11 KB (341 words) - 11:45, 21 February 2024
  • Navigation: Models ➔ Control 2 Models ➔ Actuator The Actuator is used to get a value from a PID block and then change the value of a tag in the model.
    5 KB (204 words) - 11:45, 21 February 2024
View ( | next 20) (20 | 50 | 100 | 250 | 500)