Discontinued Models and Dlls
Navigation: User Guide ➔ Upgrading Projects ➔ Discontinued Models and DLLs
SysCAD Project Upgrade | Project Upgrade Procedure | Upgrade Tag Changes | Changes that Affect Results | Discontinued Models and DLLs |
---|
Latest SysCAD Version: 25 October 2024 - SysCAD 9.3 Build 139.36522
Summary of Discontinued Models / Dlls
Discontinued Model | Alternative Model | Discontinued in Version | Removed from Distribution in Version | ||
---|---|---|---|---|---|
The following models have been Discontinued. | |||||
Generic Bayer Species Model | Alumina 3 Bayer Species Model | 9.3 Build 136 | 9.3 Build 137 | ||
Precipitation Model | Precipitation3 | ||||
Screen | Screen 2 | 9.3 Build 137 | 9.3 Build 139 | ||
Cyclone | Hydrocyclone | ||||
Area | None | 9.3 Build 139 | 9.3 Build 139 | ||
The following models will be discontinued in the Next Major Build/Version updates. | |||||
Crusher1 | Crusher2 | Next Major Build | Next Major Build | ||
Mill-1 | Crusher2 | ||||
Falling Film Evaporator | Falling Film Evaporator 4 | ||||
OLI Chemistry Model | OLI Model Configuration | ||||
OLI Sample Model | OLI Direct Calc Model | ||||
OLI Reactor | OLI Reactor 2 | ||||
The following models will be discontinued in future Major Build/Version updates. | |||||
Direct Contact Heater | Direct Contact Heater 2 | Future versions | |||
Heat Exchanger | Shell and Tube Heat Exchanger 2 or Simple Heat Exchanger | ||||
Flash Tank | Flash Tank 2 | ||||
Falling Film Evaporator 2 | Falling Film Evaporator 4 | ||||
Shell and Tube Heat Exchanger | Shell and Tube Heat Exchanger 2 |
Discontinued Dll | Discontinued in Version | Removed from Distribution in Version |
---|---|---|
Alumina.dll | 9.3 Build 136 | 9.3 Build 137 |
ScdOLI.dll | Next Major Build | Next Major Build |
Separ1.dll | 9.3 Build 139 | 9.3 Build 139 |
Separ2.dll | 9.3 Build 137 | 9.3 Build 139 |
XBasic.dll | 9.3 Build 138 | 9.3 Build 138 |
Discontinued Models
When a model is discontinued, user usually gets some time to change the model over to an alternate, improved model.
- During this grace period, discontinued models should still load and project will run as is. However, user are not able to add anymore of these models into the project.
- Existing units using these models are listed with a message to change the model. We strongly recommend user to make the change sooner rather than later, as the new unit models will be improved and have more functionality.
- Please see the table above for the suggested alternate/replacement model.
Discontinued models will be removed from distribution after a while, when it is removed from distribution, they will no longer work in the project.
Discontinued Models Removed from Distribution
Models that have been removed from distribution will no longer work. Projects containing these old legacy models will not load.
For example, the screen model has been removed completely in Build139, so projects with the old screen model will not load.
- To fix this issue, please change the model to Screen 2 using Build138 or earlier before upgrading to Build139.
- See Build139 Project Upgrade
Discontinued dll (no longer required)
Discontinued dlls are no longer required. If you are getting warning messages using project load, please check:
- an old version of the dll is not in the Bin folder
- update the configuration file so it is not trying to load an old dll. See Upgrading Project with Discontinued dlls.