- Flash Tank 2 (section Data Sections)and would usually be the last sub-model evaluated. Other sub-models allowed as part of the Evaluation Block (EB) are Makeup Block (MU), Reaction Block (RB)9 KB (889 words) - 09:29, 2 February 2024
- Phase Change (PC) (section Data Sections)Navigation: Models ➔ Sub-Models ➔ Evaluation Blocks ➔ Phase Change (PC) Related Links: Evaluation Blocks, Solubility, Potash Solubility, Plant Model -9 KB (537 words) - 01:41, 6 September 2023
- be enabled in the Evaluation Block (EB) in a unit. Therefore, the user must be careful to ensure that the order of evaluation in the EB will produce the36 KB (1,127 words) - 03:33, 5 April 2024
- Model Procedures (section Data Sections)e. if it is used in the function MP_Eval_BeforeEB(), then it may be stream feeding into the Evaluation Block; or An indeterminate value. Therefore, please20 KB (1,014 words) - 01:44, 6 September 2023
- Tank - Dynamic Mode (section Data Sections)selected, then NONE of the EB sub models will be available Two groups of sub-models are allowed in a Dynamic Tank: Evaluation Block (EB) sub-models that act43 KB (2,552 words) - 16:25, 25 January 2024
- General Separator (section Data Sections)outlets. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible6 KB (942 words) - 09:26, 2 February 2024
- Thickener (section Data Sections)several sections: Thickener1 tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB.PhaseChange@T9 KB (803 words) - 05:13, 21 February 2024
- Pipe (section Data Sections)disable Simplify and then the Evaluation Block (EB) will be visible. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled23 KB (1,392 words) - 10:18, 3 August 2023
- Tank (section Data Sections)events if any Evaluation Block sub-model options or the HX Block are enabled: The tank access window may consist of a number of sections. This number may12 KB (1,353 words) - 18:49, 25 January 2024
- Feeder-Cross Page Connector (section Data Sections)Please see DSSA Data Sections for more information. The configuration options for the feeder will be based on Operation mode selected. CF and EB groups are47 KB (2,683 words) - 09:04, 2 February 2024
- Direct Contact Heater 2 (section Data Sections)no BPE data in the species database, then the equilibrium point will be that of saturated steam, as found in Steam Tables. If there is BPE data in the26 KB (2,038 words) - 09:28, 2 February 2024
- Flotation Cell (section Data Sections)chosen. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible19 KB (1,611 words) - 05:14, 7 February 2024
- Pipe - Dynamic Mode (section Data Sections)disable Simplify and then the Evaluation Block (EB) will be visible. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled28 KB (655 words) - 19:00, 2 August 2023
- Tie (section Data Sections)unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. MU - Optional tab, or multiple tabs9 KB (1,053 words) - 09:22, 2 February 2024
- Drum Filter (section Data Sections)consists of three sections: DrumFilter tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On is11 KB (855 words) - 04:36, 21 February 2024
- Washer (section Data Sections)outlets are swapped around. The default access window consists of several sections, Washer tab - Contains general information relating to the unit. RB - Optional15 KB (1,264 words) - 05:13, 21 February 2024
- Disk Centrifuge (section Data Sections)environment. PC - Optional tab that is visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible8 KB (672 words) - 04:35, 21 February 2024
- Classifier (section Data Sections)several sections, Classifier tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On and/or EB.PhaseChange@T8 KB (643 words) - 04:18, 21 February 2024
- Counter Current Washer (section Data Sections)consists of several sections, CCWasher tab - Contains general information relating to the unit. PC - Optional tab that is visible if EB.Solubility.On is enabled11 KB (919 words) - 04:35, 21 February 2024
- Reverse Osmosis (RO) Unit (section Data Sections)unit PC - Optional tab, only visible if EB.Solubility.On and/or EB[email protected] is enabled in the Evaluation Block. RB - Optional tab, only visible10 KB (795 words) - 09:23, 2 February 2024