Search results
Jump to navigation
Jump to search
- PHREEQC Reverse Osmosis (section Data Sections)PHREEQC algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to PHREEQC streams is done via Species Mapping. The PHREEQC10 KB (2,093 words) - 17:33, 21 June 2024
- PHREEQC Side Calc (section Data Sections)algorithms and data to determine the status of the aqueous solution in the defined stream/s. Mapping of the SysCAD to PHREEQC streams is done via Species Mapping7 KB (1,711 words) - 17:17, 21 June 2024
- of species that have been developed for use with sugar solutions, although any species may be added. The species and descriptions are in the table below27 KB (1,424 words) - 13:59, 27 March 2024
- Table lookup using Array and Matrix (section PGM FILE - Look up Gypsum Solubility from a Table using SysCAD 9.3 Syntax)Temperature = {25, 30, 35} const Array AcidConc = {0, 9.8} const matrix GypsumSolubility = { {2.12, 2.11, 2.10}, {1.77, 1.82, 1.88} } ;Array Temperature = {255 KB (565 words) - 04:22, 27 January 2023
- TagSelect Class (section Data Members)have surge). Example 2: Dynamic Project Overall Mass Balance See How to perform a Species Mass Balance See also Example PGM - Species Check for how to check6 KB (462 words) - 02:45, 5 February 2024
- PHREEQC Solvent Extraction (section Data Sections)ensure the organic species are defined with a lower density than the aqueous species. This requires the specification of appropriate data for organic-aqueous9 KB (1,955 words) - 15:55, 21 June 2024
- Precipitator3 Model Theory (section Bound Soda Species)set nFC = -2, nC = 2 : [math]\displaystyle{ \left(\cfrac{A_o - A^*}{F}\right)^2=\left(\cfrac{A_o - A^*}{C}\right)^2 \times \cfrac{C^2}{F^2} }[/math] SAL33 KB (3,902 words) - 23:27, 22 February 2024
- OLI Side Calc (section Data Sections)algorithms and data to determine the status of the aqueous solution in the defined stream/s. Mapping of the SysCAD to OLI streams is done via Species Mapping7 KB (1,677 words) - 17:28, 21 June 2024
- OLI Solvent Extraction (section Data Sections)the OLI algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to OLI streams is done via Species Mapping. The OLI Mixer9 KB (1,831 words) - 17:29, 21 June 2024
- PHREEQC Reactor (section Data Sections)PHREEQC algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to PHREEQC streams is done via Species Mapping. The PHREEQC7 KB (1,742 words) - 15:55, 21 June 2024
- PHREEQC Flash Tank (section Data Sections)Vapour is flashed off and the remaining solution is then supersaturated with the required species. This species then precipitates out as the crystal product8 KB (1,762 words) - 15:55, 21 June 2024
- PHREEQC Direct Calc (section Data Sections)calculations to generate a set of data. The data can be copied and pasted into external programs such as Excel to allow the data to be plotted and analysed.6 KB (1,196 words) - 17:17, 21 June 2024
- AQSol Reverse Osmosis (section Data Sections)AQSol algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to AQSol streams is done via Species Mapping. The AQSol10 KB (2,061 words) - 17:41, 21 June 2024
- 138 to Build 139. A table of the SysCAD 9.3 Build 139 changes at the time of first release are shown below. Please click on the table headings, or use the17 KB (139 words) - 17:48, 2 August 2023
- OLI Reverse Osmosis (section Data Sections)the OLI algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to OLI streams is done via Species Mapping. The OLI Reverse10 KB (2,101 words) - 17:35, 21 June 2024
- OLI Feeder (section Data Sections)the OLI algorithms and data to determine the status of the aqueous solution. Mapping of the SysCAD to OLI streams is done via Species Mapping. The OLI Feeder5 KB (1,287 words) - 17:29, 21 June 2024
- PHREEQC Evaporator (section Data Sections)Evaporator has solubility data for the species, then the amount of species that precipitates will be automatically calculated. The solution properties will be9 KB (2,350 words) - 15:55, 21 June 2024
- OLI Model Configuration (section Data Sections)'map' OLI species/ions to SysCAD species/ions used in the project. This allows the other OLI models in SysCAD to convert the SysCAD species flow data to OLI6 KB (1,156 words) - 17:27, 21 June 2024
- AQSol Flash Tank (section Data Sections)Vapour is flashed off and the remaining solution is then supersaturated with the required species. This species then precipitates out as the crystal product8 KB (1,729 words) - 17:40, 21 June 2024
- OLI Flash Tank (section Data Sections)Vapour is flashed off and the remaining solution is then supersaturated with the required species. This species then precipitates out as the crystal product8 KB (1,763 words) - 17:28, 21 June 2024