Template:TPS Bypass Tab Page

From SysCAD Documentation
Jump to navigation Jump to search

This tab is only visible if the WithBypass option is enabled on the TCE tab page. This will allow some or all of the SysCAD species to bypass the thermodynamic engine calculations.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Specify Bypass of Feed
BypassMode Species A bypass fraction can be set for each species in the project.
Phases A bypass fraction can be set for each phase (Solid, Liquid or Vapour) in the project.
BypassUnmapped BypassUnmapped Button.png If this button is pressed then the bypass fraction for all Unmapped Species will be set to 100%. This is only relevant if BypassMode = Species.
NOTE: There is no automatic undo for this function. It is recommended to bypass all species in the SysCAD model which are not present in the {{{TPS}}} model you are using.
ShowUnmappedSpecies Tickbox If ticked, all the unmapped species will be displayed in a list immediately under this field.
BypassSpCount Calc The number of species to be bypassed.
PhaseBypass... (only displayed if BypassMode = Phases)
PhaseBypass.Solid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD solid species. A non-zero value will allow some or all (100%) of the SysCAD solid species to bypass the thermodynamic engine calculations.
PhaseBypass.Liquid.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD liquid species. A non-zero value will allow some or all (100%) of the SysCAD liquid species to bypass the thermodynamic engine calculations.
PhaseBypass.Vapour.MF Input Only displayed if BypassMode = Phases. The user specified Bypass fraction for all SysCAD vapour species. A non-zero value will allow some or all (100%) of the SysCAD vapour species to bypass the thermodynamic engine calculations.
The remaining fields are only displayed if BypassMode = Species)
On Button - Filter On.png
Button - Filter Off.png
This button will enable or disable the species filter options.
Phases
(Only visible if Filter is enabled)
All No filtering of species based on phase.
Solids Only show solid phase species, hide other species.
Liquids Only show liquid phase species, hide other species.
Vapours Only show vapour (gaseous) phase species, hide other species.
Solids & Liquids Only show solid and liquid phase species, hide other species.
Solids & Vapours Only show solid and vapour (gaseous) phase species, hide other species.
Liquids & Vapours Only show liquid and vapour (gaseous) phase species, hide other species.
IPhase Only show "IPhase" individual phase species, hide other species. The individual phases shown will depend on the {{{TPS}}} database chosen.
Filters Display Always set to 'Content'.
Content
(Only visible if Filter is enabled)
All No filtering of species based on element or name.
Contains Any Element This will display all species that contain any of the elements entered in their elemental definition.
Contains All Elements This will display only species that contain ALL of the elements entered in their elemental definition.
Starts with ... This will display species that start with the text entered based on the short or long species tag depending on the current SpeciesTag selection.
Contains any ... This will display species that contain the text entered in the currently displayed short or long species tag.
Contains All ... This will display species that contain ALL the separate text entered in the currently displayed short or long species tag.
Select Input Only visible if Filter is enabled and Content is NOT set to All. The user specified Elements or text to filter the species list. Refer to Species Filter for more information and examples.
GroupValue Input The user specified bypass value that will be used for all species displayed when the Set to GroupValue button is pressed.
SetVisible Set to GroupValue.png When pressed, this button will set the bypass parameter for all species currently displayed (based on Filter settings) equal to the GroupValue.
SysCAD Feed Stream Bypass
(The following table displays all the SysCAD species in the project (unless restricted by the Filter settings). The table has the following column (one row per SysCAD species):)
Bypass.XXX Input The user specified Bypass fraction for SysCAD species XXX. A non-zero value will allow some or all (100%) of the SysCAD species to bypass the thermodynamic engine calculations.