Unit Type: {{{TCE}}}Tank - The first tab page in the access window will have this name.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.
If this field is blank, then SysCAD will display the UnitType or SubClass.
Requirements (Tank Size)
Capacity.Volume Input The volume of the tank. Visible in dynamic mode only.
Outlet.Filter Input The selected filter for the outlet line from the tank: None, Block-Solids, Block-Liquids, Composition
Outlet.Composition.Sf Input Only visible when Composition is selected. The required solid fraction of the outlet stream.
Outlet.Composition.Lf Input Only visible when Composition is selected. The required liquid fraction of the outlet stream.
Outlet.Composition.Vf Input Only visible when Composition is selected. The required vapour fraction of the outlet stream.
Requirements
Prod...
Outlet P_XXX
CapacityControl Input Method for capacity control in the outlet line: None, ByMassFlow, ByVolumeFlow.
Qm.Capacity Input Only visible if CapacityControl is ByMassFlow. The capacity of the outlet line.
Qm.MinCap Input Only visible if CapacityControl is ByMassFlow. The minimum capacity of the outlet line.
Qm.MaxCap Input Only visible if CapacityControl is ByMassFlow. The maximum capacity of the outlet line.
Qv.Capacity Input Only visible if CapacityControl is ByVolumeFlow. The capacity of the outlet line.
Qv.MinCap Input Only visible if CapacityControl is ByVolumeFlow. The minimum capacity of the outlet line.
Qv.MaxCap Input Only visible if CapacityControl is ByVolumeFlow. The maximum capacity of the outlet line.
OverCapacity Input Method for handling overcapacity in the outlet line: Spill or Accept.
BatchMethod Input Batch method. By Total Mass or by total volume when operating by a batch.
OperatingP - NOTE: this pressure is applied to the (combined) feed, before sub-models (if any).
Method AutoDetect If there are any liquids AND no vapours present in the feed, outlet streams will take the highest pressure of the feeds. Else (e.g. some vapours present) outlet streams will take the lowest pressure of the feeds.
LowestFeed Outlet streams will take the lowest pressure of the feeds.
HighestFeed Outlet streams will take the highest pressure of the feeds.
Atmospheric Outlet streams will be at Atmospheric Pressure. The atmospheric pressure is calculated by SysCAD based on the user defined elevation (default elevation is at sea level = 101.325 kPa). The elevation can be changed on the Environment tab page of the Plant Model.
RequiredP Outlet streams will be at the user specified pressure.
IgnoreLowMassFlow / IgnoreLowQm Tick Box This option is only visible if the AutoDetect, LowestFeed or HighestFeed methods are chosen. When calculating the outlet pressure and temperature of the tank, SysCAD will ignore the low flow feed streams should this option be selected. The low flow limit is set in the field below.
LowMassFlowFrac / LowQmFrac Input This field is only visible if the IgnoreLowQm option is selected. This is the amount any stream contributes to the total flow. For example, if the total feed to the tank is 10 kg/s, and this field is set to 1%. Then any feed streams with less than 0.1 kg/s will be ignored in the pressure calculations.
PressureReqd / P_Reqd Input This field is only visible if the RequiredP method is chosen. This is user specified pressure.
Result Calc The actual pressure used for the sum of the feeds which will also be the outlet pressure (unless further model options change the pressure).
PresetData...
UsePreset Tickbox If ticked, will allow user to set temperature, level and composition of the tank at startup. The composition can be set on the Preset tab page.
Options
TrackOverflow Tickbox If ticked, will enable warnings if material is sent to overflow stream.
ShowQFeed Tickbox Allows the user to view the QFeed and associated tab pages, showing the properties of the combined feed stream. See Material Flow Section. This will be prior to any sub-model actions, mixing with the tank content or {{{TCE}}} calculations.
ShowQOF Tickbox Allows the user to view the QOF and associated tab pages, showing the properties of the overflow stream. See Material Flow Section. This will be the perfectly mixed tank contents after {{{TCE}}} calculations.
ShowQOutlet Tickbox Allows the user to view the QOutlet and associated tab pages, showing the properties of the outlet stream. See Material Flow Section. This will be the perfectly mixed tank contents after {{{TCE}}} calculations with the filter applied.
Results Summary (Tank)
Temperature / T Calc The current temperature of the contents of the tank.
Density / Rho Calc The current density of the contents of the tank.
TotalVol / Vt Calc The current volume of the contents of the tank.
Level / Lvl Calc The current level of the contents of the tank.
TotalMass / Mt Calc The current mass of the contents of the tank.
InitTtlMass / InitMt Calc The mass of the contents of the tank at the start of the solver run.
DeltaTtlMass / DeltaMt Calc The total change in mass of the contents of the tank since the start of the solver run (TotalMass - InitTtlMass).
MassRateOfChange / QmAcc Calc The rate of accumulation of mass in the content of the tank.
MtAcc Calc The total change of mass over the time step.
Results Summary (Outlet Stream)
Outlet.MassFlowReqd / Outlet.QmReqd Calc Outlet mass flowrate required applied to the outlet pipe (minimum of above 3 specifications).
Outlet.MassFlow / Outlet.Qm Calc Actual outlet mass flowrate in outlet stream.