Template:TCETank Tab Page
Jump to navigation
Jump to search
Unit Type: {{{TCE}}}Tank - The first tab page in the access window will have this name.
Tag (Long/Short) | Input / Calc | Description/Calculated Variables / Options |
Tag | Display | This name tag may be modified with the change tag option. |
Condition | Display | OK if no errors/warnings, otherwise lists errors/warnings. |
ConditionCount | Display | The current number of errors/warnings. If condition is OK, returns 0. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here. If this field is blank, then SysCAD will display the UnitType or SubClass. |
Requirements | ||
Capacity.Volume | Input | The volume of the tank. Visible in dynamic mode only. |
OperatingP - NOTE: this pressure is applied to the (combined) feed, before sub-models (if any). | ||
Method | AutoDetect | If there are any liquids AND no vapours present in the feed, outlet streams will take the highest pressure of the feeds. Else (e.g. some vapours present) outlet streams will take the lowest pressure of the feeds. |
LowestFeed | Outlet streams will take the lowest pressure of the feeds. | |
HighestFeed | Outlet streams will take the highest pressure of the feeds. | |
Atmospheric | Outlet streams will be at Atmospheric Pressure. The atmospheric pressure is calculated by SysCAD based on the user defined elevation (default elevation is at sea level = 101.325 kPa). The elevation can be changed on the Environment tab page of the Plant Model. | |
RequiredP | Outlet streams will be at the user specified pressure. | |
IgnoreLowMassFlow / IgnoreLowQm | Tick Box | This option is only visible if the AutoDetect, LowestFeed or HighestFeed methods are chosen. When calculating the outlet pressure and temperature of the tank, SysCAD will ignore the low flow feed streams should this option be selected. The low flow limit is set in the field below. |
LowMassFlowFrac / LowQmFrac | Input | This field is only visible if the IgnoreLowQm option is selected. This is the amount any stream contributes to the total flow. For example, if the total feed to the tank is 10 kg/s, and this field is set to 1%. Then any feed streams with less than 0.1 kg/s will be ignored in the pressure calculations. |
PressureReqd / P_Reqd | Input | This field is only visible if the RequiredP method is chosen. This is user specified pressure. |
Result | Calc | The actual pressure used for the sum of the feeds which will also be the outlet pressure (unless further model options change the pressure). |
PresetData... | ||
UsePreset | Tickbox | If ticked, will allow user to set temperature, level and composition of the tank at startup. The composition can be set on the Preset tab page. |
Temperature / T | Input | Only visible if UsePreset has been enabled. The temperature of the contents of the tank at startup. |
Pressure / P | Input | Only visible if UsePreset has been enabled. The pressure of the contents of the tank at startup. |
Level | Input | Only visible if UsePreset has been enabled. The level of the tank at startup. |
Options | ||
TrackOverflow | Tickbox | If ticked, will enable warnings if material is sent to overflow stream. |
ShowQFeed | Tickbox | Allows the user to view the QFeed and associated tab pages, showing the properties of the combined feed stream. See Material Flow Section. This will be prior to any sub-model actions, mixing with the tank content or {{{TCE}}} calculations. |
ShowQOF | Tickbox | Allows the user to view the QOF and associated tab pages, showing the properties of the overflow stream. See Material Flow Section. This will be the perfectly mixed tank contents after {{{TCE}}} calculations. |
ShowQOutlet | Tickbox | Allows the user to view the QOutlet and associated tab pages, showing the properties of the outlet stream. See Material Flow Section. This will be the perfectly mixed tank contents after {{{TCE}}} calculations with the filter applied. |
Results Summary (Tank) | ||
Temperature / T | Calc | The current temperature of the contents of the tank. |
Density / Rho | Calc | The current density of the contents of the tank. |
TotalVol / Vt | Calc | The current volume of the contents of the tank. |
Level / Lvl | Calc | The current level of the contents of the tank. |
SolidFrac / Sf | Calc | The current fraction of solids in the contents of the tank. |
TotalMass / Mt | Calc | The current mass of the contents of the tank. |
InitTtlMass / InitMt | Calc | The mass of the contents of the tank at the start of the solver run. |
DeltaTtlMass / DeltaMt | Calc | The total change in mass of the contents of the tank since the start of the solver run (TotalMass - InitTtlMass). |
MassRateOfChange / QmAcc | Calc | The rate of accumulation of mass in the content of the tank. |
MtAcc | Calc | The total change of mass over the time step. |
Results Summary (Outlet Streams) | ||
(The following group of tags are shown for each Product outlet stream connected to the Tank) | ||
XXX Outlet Stream | ||
XXX ... | ||
CapControl.MassFlowReqd / QmReqd | Calc | Outlet mass flowrate required based on capacity control requirements (only relevant if downstream pipe is in push mode). |
Pull.MassFlowReqd / QmReqd | Calc | Outlet mass flowrate required based on downstream pull requirements (only relevant if downstream pipe is in pull mode). |
MassFlowReqd / QmReqd | Calc | Outlet mass flowrate required applied to the outlet pipe (minimum of above 2 specifications). |
MassFlow / Qm | Calc | Actual outlet mass flowrate of the outlet stream. |
VolFlow / Qv | Calc | Actual outlet volumetric flowrate of the outlet stream. |