Template:TCEPond Tab Page

From SysCAD Documentation
Jump to navigation Jump to search

Unit Type: {{{TCE}}}Pond - The first tab page in the access window will have this name.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.
If this field is blank, then SysCAD will display the UnitType or SubClass.
Requirements (Pond Size)
Capacity.Volume Input The volume of the pond.
Pond/Capacity.Area Input The surface area of the pond.
Pond/Capacity.Depth Calc The depth of the pond, calculated by Depth = Volume / Area.
Requirements
TemperatureReqd / T_Reqd Input The required temperature of the pond.
Rxns.Option None There are no reactions in the pond.
TCE {{{TCE}}} calculations will be performed on the pond contents.
CRB The user can specify reactions to occur on the pond contents. If this is selected then the associated page, CRB becomes visible and may be configured.
Note: The user does not have to configure a reaction file, even if this option is selected.
TCE_LiqBypassFrac Input Only visible if Rxns.Options = TCE. The fraction of the liquids that bypass the {{{TCE}}} calculations.
TCE_SolBypassFrac Input Only visible if Rxns.Options = TCE. The fraction of the solids that bypass the {{{TCE}}} calculations.
Rxns.LiqBypassFrac Input Only visible if Rxns.Options = CRB. The fraction of the liquids that bypass the reaction block.
Rxns.SolBypassFrac Input Only visible if Rxns.Options = CRB. The fraction of the solids that bypass the reaction block.
BedLayer.Partition Tickbox Separates the contents of the pond into two layers, Clarified Liquor and Bed. The Bed layer is the bottom layer.
BedLayer.FracOfSolids Input Only visible if BedLayer.Partition has been enabled. The fraction of the solids that report to the Bed layer.
BedLayer.LiquidFrac Input Only visible if BedLayer.Partition has been enabled. The fraction liquids in the Bed layer.
Requirements (Evaporation)
Evap.Method None There is no evaporation from the pond.
Massflow The user can specify the mass flow of water to be evaporated.
Volumeflow The user can specify the volume flow of water to be evaporated.
Height Rate The user can specify the rate of evaporation of water as a length per unit time. This will be multiplied by the surface area of the pond to obtain a volume of water to be evaporated.
Evap.QmReqd Input Only visible if Evap.Method = Massflow. The mass flow of water to be evaporated.
Evap.QvReqd Input Only visible if Evap.Method = Volumeflow. The volume flow of water to be evaporated.
Evap.RateReqd Input Only visible if Evap.Method = Height Rate. The required evaporation rate.
Evap.MinWaterFrac Input Visible if Evap.Method is any method other than None. The minimum fraction of water to be maintained in the pond. Evaporation may be less than specified to prevent the fraction of water being less than this value.
EB... (Evaluation Block)
EvalSequence Calc The sequence in which the sub models (which are part of the evaluation blocks) will be calculated. The sequence is determined by the priority selection for the individual sub-models.
Note: If the user chooses On-AutoSequence then SysCAD will determine the sequence of the sub-models. The auto evaluation sequence followed will be the order the sub models are listed below.
Makeups Input The number of Makeup Blocks required. Extra dropdown options Makeup1, Makeup2, etc. will be added to allow these to be switched on and off and prioritised in relation to the other sub-models.
MakeupX List This can be used to switch the Makeup Block (MU) on or off and prioritise it in relation to the other sub-models. If this is 'On' then the associated page, MUX becomes visible and may be configured.
Note: This field is only visible if the entry for 'Makeups' is greater than 0. If there is one makeup then X=1. If there are two makeups, then X=1 and X=2, etc.
PresetData...
UsePreset Tickbox If ticked, will allow user to set temperature, level and composition of the pond at startup. The composition can be set on the Preset tab page.
Temperature / T Input Only visible if UsePreset has been enabled. The temperature of the contents of the pond at startup.
Level Input Only visible if UsePreset has been enabled. The level of the pond at startup.
Options
TrackOverflow Tickbox If ticked, will enable warnings if material is sent to overflow stream.
ShowQFeed Tickbox Allows the user to view the QFeed and associated tab pages, showing the properties of the combined feed stream. See Material Flow Section. This will be prior to any sub-model actions, mixing with the pond content or {{{TCE}}} calculations.
ShowBed Tickbox Only visible if BedLayer.Partition has been enabled. Allows the user to view the Bed and associated tab pages, showing the properties of the Bed layer. See Material Content Section.
ShowCL Tickbox Only visible if BedLayer.Partition has been enabled. Allows the user to view the CL and associated tab pages, showing the properties of the Clarified Liquor layer. See Material Content Section.
ShowQCL Tickbox Only visible if CL_Out outlet has been connected. Allows the user to view the QCL and associated tab pages, showing the properties of the Clarified Liquor outlet stream. See Material Flow Section.
ShowQBed Tickbox Only visible if Bed_Out outlet has been connected. Allows the user to view the QBed and associated tab pages, showing the properties of the Bed outlet stream. See Material Flow Section.