Unit Type: {{{TCE}}}FlashTank - The first tab page in the access window will have this name.
Tag (Long/Short) | Input/ Calc | Description |
---|---|---|
Tag | Display | This name tag may be modified with the change tag option. |
Condition | Display | OK if no errors/warnings, otherwise lists errors/warnings. |
ConditionCount | Display | The current number of errors/warnings. If condition is OK, returns 0. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here. If this field is blank, then SysCAD will display the UnitType or SubClass. |
Requirements | ||
On | Tickbox | This variable in used to enable flashing in the unit. If this not selected, the material will flow out of the liquor outlet with no change in state, i.e. the unit acts as a pipe. |
Mode | Stand Alone (Manual) | The flash tank will not form part of a flash train. |
Flash Train | The flash tank will form part of a Flash Train if appropriate units are connected to it. The OperatingP - Method will be set to Saturated. | |
OperatingP The user may only set the operating pressure or temperature of the {{{TCE}}} Flash Tank if it is NOT part of a Flash Train. | ||
Method | Atmospheric | This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at Atmospheric Pressure. The atmospheric pressure is calculated by SysCAD based on the user defined elevation (default elevation is at sea level = 101.325 kPa). The elevation can be changed on the Environment tab page of the Plant Model. |
RequiredP | This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at the user specified pressure (and saturated temperature @ P). | |
RequiredT | This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at the user specified temperature (and saturated pressure @ T). | |
Saturated | The OperatingP - Method will be set to Saturated if 'Flash Train' Mode is chosen. All flash calculations will be done at the saturated pressure. | |
PressureReqd / P_Reqd | Input | This field is only visible if the RequiredP method is chosen. This is user specified flash pressure. |
TemperatureReqd / T_Reqd | Input | This field is only visible if the RequiredT method is chosen. This is user specified flash temperature. |
Result | Calc | The actual pressure used for the sum of the feeds which will also be the outlet pressure (unless further model options change the pressure). |
MinFlashP | Input | This is only visible when 'Flash Train' Mode is chosen. The Minimum Flash Pressure. |
Options | ||
VapStandardSpModel | Tick Box | If ticked then the Standard (default) species model will be used in the vapour exit stream. This selection has no effect on the model operation. |
ShowQFeed | Tick Box | QFeed and associated tab pages (e.g. Sp) will become visible if this is enabled. These tabs will show the properties of the combined feed stream to the Unit. These values are BEFORE any flashing calculations or other sub-models occur. |
ShowQProd | Tick Box | QProd and associated tab pages (e.g. Sp) will become visible if this is enabled. These tabs will show the properties of the combined product streams from the Unit. These values are after any flashing calculations or other sub-models occur but before the final phase split is made. |
Vapour Entrainment | ||
FlashVapToLiquid | Input | This field allows the user to set a proportion of the flash vapour bypassing to the liquid stream. The default is 0%. |
OtherGasToLiquid | Input | This field allows the user to set a proportion of any non-condensable gas bypassing to the liquid stream. The default is 0%. |
Results | ||
TemperatureIn / Ti | Calc | The flash tank feed temperature. |
PressureIn / Pi | Calc | The flash tank feed pressure. |
BPE | Calc | The Boiling Point Elevation of the Flash Tank discharge. This is the BPE value that is used for the Flash calculations. |
HeatFlow | Calc | Any environmental heat loss will be displayed here. |
FlashT | Calc | The calculated temperature at the operating pressure of the Flash Tank. |
FlashP | Calc | The calculated operating pressure of the Flash Tank. |
VapourMassFlow / VQm | Calc | The mass flow of flashed vapour. |
Flash Train Macro Model
These extra fields are only visible if the unit is part of a Flash Train. | ||
VapourMassFlow / VQm | Calc | The mass flow of flashed vapour. |
PressureReqd / P_Reqd | Calc | The required flash pressure calculated by the Flash Train. |
TotalPressChange / TotaldP | Calc | The total pressure change calculated by the Flash Train. |
FeedSatP | Calc | The saturation pressure of the feed. |
FlashTrain | Display | A unique tag assigned to the flash train by SysCAD. Each unit in the flash train will have the same tag in this block. |
FlashTearBlock | Display | Displays the name of the tear block that is part of the Flash Train. |
FlashTrainEqp | List | This contains a list of all of the equipment tags in this flash train. the list might be as follows: FT_FT_001 FT_ST2_001 |
PAdvBase | Input | Additional damping or acceleration for calculated pressure change (DP) for the iteration. DP = DP * PAdvBase when PAdvExtra=0. |
PAdvExtra | Input | Additional damping or acceleration for calculated pressure change (DP) for the iteration. DP = DP * (PAdvBase + PAdvExtra*(VQmReqd-VQm)/Max(VQmReqd,VQm)). |