Template:Mass and Volume Flow Data Section

From SysCAD Documentation
Jump to navigation Jump to search

|- | font style="background: #ebebeb" colspan="3" |Mass Flow |- | MassFlow / Qm || font style="background: #ebebeb" | Calc || The total mass flow into the pipe. |- | SolidMassFlow / SQm || font style="background: #ebebeb" | Calc || The mass of solids flowing into the pipe. |- | LiquidMassFlow / LQm || font style="background: #ebebeb" | Calc || The mass of liquids flowing into the pipe. |- | VapourMassFlow / VQm || font style="background: #ebebeb" | Calc || The mass of vapour flowing into the pipe. |- | SlurryMassFlow / SLQm || font style="background: #ebebeb" | Calc || The mass of slurry flowing into the pipe. |- | AqDissolvedMassFlow / AqDissQm || font style="background: #ebebeb" | Calc || The mass of dissolved aqueous species flowing into the pipe. This will be the flow of all aqueous species excluding water. |- | AqueousMassFlow / AqQm || font style="background: #ebebeb" | Calc || The mass of all aqueous species (including water) flowing into the pipe. |- | font style="background: #ebebeb" colspan="3" | Volume Flow |- | VolFlow / Qv || font style="background: #ebebeb" | Calc || The total volume flow into the pipe. |- | SolidVolFlow / SQv || font style="background: #ebebeb" | Calc || The volume of solids flowing into the pipe. |- | LiquidVolFlow / LQv || font style="background: #ebebeb" | Calc || The volume of liquids flowing into the pipe. |- | VapourVolFlow / VQv || font style="background: #ebebeb" | Calc || The volume of vapour flowing into the pipe. |- | SlurryVolFlow / SLQv || font style="background: #ebebeb" | Calc || The volume of slurry flowing into the pipe. |- | font style="background: #ebebeb" colspan="3" | Normal Volume Flow |- | NVolFlow / NQv || font style="background: #ebebeb" | Calc || The normalised volumetric flow through the pipe. The volume is calculated at Normal Temperature and Presure (NTP). NTP can be specified by the user in the configuration file (see Project Configuration (cfg File)). Default values are 20°C and 101.325kPa. |- | SolidNVolFlow / SNQv || font style="background: #ebebeb" | Calc || The Normal volume of solids flowing into the pipe. |- | LiquidNVolFlow / LNQv || font style="background: #ebebeb" | Calc || The Normal volume of liquids flowing into the pipe. |- | VapourNVolFlow / VNQv || font style="background: #ebebeb" | Calc || The Normal volume of vapour flowing into the pipe. |- | SlurryNVolFlow / SLNQv || font style="background: #ebebeb" | Calc || The Normal volume of slurry flowing into the pipe. |- | font style="background: #ebebeb" colspan="3" | Totalised Mass Flow These fields are only visible in a dynamic project, when Audit is turned on from the Plant Model. Only some of these fields may be shown depending on the Totaliser Flow options chosen. |- |Total.TotalMass / Total.Mt || font style="background: #ebebeb" | Calc || The total mass which has flowed through the pipe since the model started running. |- |Total.SolidMass / Total.SMt || font style="background: #ebebeb" | Calc ||The total mass of solids which has flowed through the pipe since the model started running. |- |Total.LiquidMass / Total.LMt || font style="background: #ebebeb" | Calc || The total mass of liquids which has flowed through the pipe since the model started running. |- |Total.VapourMass / Total.VMt || font style="background: #ebebeb" | Calc ||The total mass of vapour which has flowed through the pipe since the model started running. |- |Total.SlurryMass / Total.SLMt || font style="background: #ebebeb" | Calc ||The total mass of slurry (solids + liquids) which has flowed through the pipe since the model started running. |- | font style="background: #ebebeb" colspan="3" | Totalised Volume Flow These fields are only visible in a dynamic project when Audit is turned on from the Plant Model. Only some of these fields may be shown depending on the Totaliser Flow options chosen. |- |Total.TotalVolume / Total.Vt|| font style="background: #ebebeb" | Calc ||The total volume which has flowed through the pipe since the model started running. |- |Total.SolidVolume / Total.SVt|| font style="background: #ebebeb" | Calc ||The total volume of solids which has flowed through the pipe since the model started running. |- | Total.LiquidVolume / Total.LVt || font style="background: #ebebeb" | Calc ||The total volume of liquids which has flowed through the pipe since the model started running. |- |Total.VapourVolume / Total.VVt || font style="background: #ebebeb" | Calc ||The total volume of vapour which has flowed through the pipe since the model started running. |- |Total.SlurryVolume / Total.SLVt|| font style="background: #ebebeb" | Calc ||The total volume of slurry (solids + liquids) which has flowed through the pipe since the model started running. |- | font style="background: #ebebeb" colspan="3" | First Flow These fields are only visible in a dynamic project when Audit is turned on from the Plant Model. Only some of these fields may be shown depending on the First Flow options chosen. |- | Qm.At.Step|| font style="background: #ebebeb" | Calc ||The step that flow first occurs in the pipe since the model started running. |- |Qm.At.Time|| font style="background: #ebebeb" | Calc ||The time that flow first occurs in the pipe since the model started running.