| Tag (Long/Short) | Input / Calc | Description/Calculated Variables / Options |
| EAudit... | ||
| Feed.Hf@T / Fd.Hf@T | Calc | Enthalpy of total feed stream based on SysCAD enthalpy calculations. |
| {{{TPS}}}.Feed.Hf@T / Fd.Hf@T | Calc | Enthalpy of total feed stream based on {{{TPS}}} enthalpy calculations. |
| {{{TPS}}}.Prod.Hf@T / Pd.Hf@T | Calc | Enthalpy of product stream based on {{{TPS}}} enthalpy calculations. |
| [email protected] / [email protected] | Calc | Enthalpy of product stream based on SysCAD enthalpy calculations. |
| Duty | ||
| Scd.Duty | Calc | The difference in enthalpy between the product and feed streams using SysCAD enthalpy calculations ([email protected] - Feed.Hf@T). |
| {{{TPS}}}.Duty | Calc | The difference in enthalpy between the product and feed streams using {{{TPS}}} enthalpy calculations ({{{TPS}}}.Prod.Hf@T - {{{TPS}}}.Feed.Hf@T). |