Template:TPS DInput Tab Page

From SysCAD Documentation
Jump to navigation Jump to search

This tab is used to define the Inputs for the {{{TPS}}} calculation, including the composition in terms of {{{TPS}}} species.

Tag (Long/Short) Input / Calc Description/Calculated Variables / Options
Required Mass/Molar Flow:
MassFlowReqd / QmReqd Input Visible with Mass StreamView. The mass flow required from the feeder.
MoleFlowReqd / QMlReqd Input Visible with Mole StreamView. The molar flow required from the feeder.
Temperature & Pressure Requirements:
Temperature / T Input The required temperature of the user input mixture.
Pressure / P Input The required pressure of the user input mixture.
StreamView Mass.png
Molar.png
If the Mass button is clicked, the {{{TPS}}} species will be entered/displayed in mass flow view.
If the Mole button is clicked, the {{{TPS}}} species will be entered/displayed in mole flow view.
DFeed...
SpeciesName SpeciesLongButton.png
SpeciesShortButton.png
The Species:Long or Short button is used to change the display of the Species names between the Short form, the Chemical compound, or the longer species names.
NetCharge Display The NetCharge of the stream.
BalancingIon List The chosen ion to be adjusted to maintain electroneutrality (zero Net Charge). If left as default "-", then no ions will be used to maintain electroneutrality and Net Charge could be non-zero.
(The following tables allow the user to specify the composition of the Input by specifying the mass or mole of the individual {{{TPS}}} species.)
(Each table (one for each phase) has the following columns (one row for each species):)
MassFlow / Qm Input Visible when Mass StreamView is selected. The user specified mass flow of each {{{TPS}}} species.
MassFrac / Mf Display Visible when Mass StreamView is selected. The mass fraction of the species in the total input.
PhaseMassFrac / IPh:Mf Display Visible when Mass StreamView is selected. The mass fraction of the species in the displayed phase.
MoleFlow / QMl Input Visible when Mole StreamView is selected. The user specified mole flow of each {{{TPS}}} species.
MoleFrac / Mlf Display Visible when Mole StreamView is selected. The mole fraction of the species in the total input.
PhaseMoleFrac / IPh:Mlf Display Visible when Mole StreamView is selected. The mole fraction of the species in the displayed phase.