Template:OperatingP FlashTank

From SysCAD Documentation
Jump to navigation Jump to search

|- |font style="background: #ebebeb" colspan="3" | OperatingP The user may only set the operating pressure or temperature of the {{{UnitOp}}} if it is NOT part of a Flash Train. |- | valign="top" rowspan="4" | Method || Atmospheric || This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at Atmospheric Pressure. The atmospheric pressure is calculated by SysCAD based on the user defined elevation (default elevation is at sea level = 101.325 kPa). The elevation can be changed on the Environment tab page of the Plant Model. |- | RequiredP || This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at the user specified pressure (and saturated temperature @ P). |- | RequiredT || This method is only available if 'Stand Alone' Mode is chosen. All flash calculations will be done at the user specified temperature (and saturated pressure @ T). |- | Saturated || 'The OperatingP - Method will be set to Saturated if 'Flash Train' Mode is chosen. All flash calculations will be done at the saturated pressure. |- | PressureReqd / P_Reqd || Input || This field is only visible if the RequiredP method is chosen. This is user specified flash pressure. |- | TemperatureReqd / T_Reqd || Input || This field is only visible if the RequiredT method is chosen. This is user specified flash temperature. |- | Result ||font style="background: #ebebeb"| Calc || The actual pressure used for the sum of the feeds which will also be the outlet pressure (unless further model options change the pressure). |- |MinFlashP|| Input ||This is only visible when 'Flash Train' Mode is chosen. The Minimum Flash Pressure.