General Options TagList

From SysCAD Documentation
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Navigation: User Guide ➔ Menu Commands ➔ Tools ➔ General Options ➔ Tag List

General Access Find Toolbars Project Graphics Drawing Colours Mouse Trends TagList

Available from Build 139.


Tag List Options

General Options Taglist139.png
Number Group Option Description
Button Small 1.png
Tag List Window Behaviour
Separate All Tag List windows are handled separately.
Size Together All Tag List windows will be sized together.
Move Together When a Tag List window is being moved, all Tag List windows will be moved.
Move and Size Together When a Tag List window is size or moved, all Tag List windows will be affected.
Treat as one SysCAD will display only ONE Tag List window at a time. The user may use the Explorer Window or the RecentTagList.png hot jump button to cycle through the different Tag List windows.
Button Small 2.png Tag List Options Show Reference Value
  • If this option is not selected, then the TagList Window is very similar to the tag list section of the Trend Window (bottom half).
  • If this option is selected, then an extra column "Reference" will be visible. This allows user to see the current and Reference values at the same time, for comparison purposes.
Show Difference Selectable when "Show Reference Value" is checked. Checking this option adds a "Diff" column to the Tag list. Displaying the difference between the current and reference value.
Show Relative Difference Selectable when "Show Reference Value" is checked. Checking this option adds a "Diff (%)" column to the Tag list. Displaying the relative difference between the current and reference value.
Copy Values to Reference on Run Checking this option will transfer the previously solved (or loaded, if not yet solved) values to the Reference column at the start of each solve automatically. While this option is selected, the Reference column is presented as result fields.
If this option is not checked, user would need to manually enter reference values, or copy values to the reference column. While this option is not selected, the Reference column is presented as input fields.
ResetToDefault.png Reset to Default Pressing this button will reset all Options on the current tab to default settings.