Trend Command Summary 9.3

From SysCAD Documentation
Jump to navigation Jump to search
Warning! Page you're reading is outdated or was archived and very likely is referring to older version of the software. Please navigate to the most recent version instead.

Navigation: User Guide -> Menu Commands 9.3 -> Trend Command Summary

This page is for SysCAD 9.3 Build 136. For the latest version of SysCAD, please see Trend Command Summary


Trend Command Icon Shortcut Key Brief Description Full Documentation Link
New Trend Window Open a new Trend Window See New Trend Window and Trend Window for more information.
Set This opens the Set dialog box, which allows you to set the start time and duration for the Trend Line View. See Set for more information.
Scroll Start Scrolls to the left (backwards in time) to the start of the trend. See Start for more information.
Backward Fast TrendBackFastButton.png Scrolls to the left (backwards in time) by an amount approximately equal to the current visible trend duration. See Backward Fast for more information.
Backward TrendBackButton.png Scrolls to the left (backwards in time) by an amount approximately equal to 1/10 current visible trend duration. See Backward for more information.
Forward Fast TrendFastForwardButton.png Scrolls to the right (forwards in time) by an amount approximately equal to the current visible trend duration. See Forward Fast for more information.
Forward TrendForwardButton.png Scrolls to the right (forwards in time) by an amount approximately equal to 1/10 current visible trend duration. See Forward for more information.
End TrendEndButton.png CtrlKey.png+K Scrolls to the end of the time line. The end of the time line is the most current time, represented by the green vertical Time Line. See End for more information.
Zoom Zoom In TrendZoomInButton.png Halves the Trend View Duration time by half, used to zooming into a section of the trend line. See Zoom In and Trend Line View for more information.
Zoom Out TrendZoomOutButton.png Doubles the Trend View Duration time, used to zooming out to view a longer trend period. See Zoom Out and Trend Line View for more information.
Fit All Range x% Apply auto-change to each selected trend line's Min/Max range value based on the full data range collected overtime. Options available are: 50, 90, 99 or 100%. See Range x% for more information.
Range x%, Min 0 Apply auto-change to each selected trend line's Max range value based on the Max value collected overtime, with the minimum value always set to 0. Options available are: 50, 90, 99 or 100% See Range x%, Min 0 for more information.
Default Resets the selected trend line's Min/Max range value back to default values. See Default for more information.
Auto On The minimum and maximum display values for trend lines will automatically change to maintain the required scale (set via Range x% or Range x%, Min 0 ). See Range x% or Range x%, Min 0 for more information.
Auto Off The minimum and maximum display values will not change automatically.
Reconnect The Active Trend Window is refreshed and tag values updated. If any tags are invalid, they are reported as errors in the Message Window. See Reconnect for more information.
Reconnect All All Trend Windows in the project are refreshed and tag values updated. If any tags are invalid, they are reported as errors in the Message Window. See Reconnect All for more information.
Record Records all Trend Tags on the active Trend Window to the Historian. Recorded Trends are marked by yellow dots to the left of the trend tags. See Record and Trend List View for more information.
Record All Records all Trend Tags in the project to the Historian. Recorded Trends are marked by yellow dots to the left of the trend tags. See Record All and Trend List View for more information.
Options Open the General Options - Trends Tab, used to set display options for each trend page. See General Options Trends 9.3 for more information.
Query Open the Query Dialog box, used to enter a request to the historian See Query for more information.