Template:Project Upgrade note 138 to 139

From SysCAD Documentation
Jump to navigation Jump to search

Project Upgrade

To ensure projects will upgrade smoothly from Build138 to Build139, users should update their projects to the latest version of Build138, make the necessary changes as listed below, solve (and re-tune model if required) before upgrading to Build139.

Updating projects in the most recent version of Build138

REQUIRED changes in Build138 - The following changes must be done in Build138 first, as methods are no longer available in Build139.
  • Solvent Extraction Unit - please change any models using the "Isotherm (Original)" method to Isotherm2 method. Please solve and retune models.
  • Precipitator3 - Projects with Precipitator3 must be updated to use "UseCorrectedBoundSoda" and "UseCorrectedCutOff", as per Build138 Project Upgrade notes. Please solve and retune models.
  • The old Screen and Cyclone models in Separ2.dll have been discontinued since Build137. These old legacy models will no longer load in Build139. Projects with these old unit models must be changed to Screen 2 and Hydrocyclone models. Please solve and retune models.
  • The old Alumina 1 Bayer Species model and Precip-1 unit model in Alumina1.dll have been discontinued since Build136. These old legacy models will no longer load in Build139. Projects with these old unit models must be changed to Alumina 3 Bayer Species Model and Precipitation3 models. Please solve and retune models.
  • PGM Variable Name Change - Maximum length of PGM variable names reduced from 64 to 50 characters. Any long tag names should be shortened.
The following changes are RECOMMENDED but optional. - These changes can be done in Build138 before project upgrade or they will be part of the project auto-upgrade process. If user wants to compare results between Build138 and Build139, then please apply these changes before project upgrade:
  • For projects with Temperature range above 800°C and using steam, please make sure Plant Model - Species tab - Species Property Overrides - Vapours is set to IF97_2 for H2O(g).Rho and H2O(g).Cp. Please solve and retune models.
  • For dynamic project using Tank as "Layered_Flow", please change the "Mixing.Model" to "Layered", please solve and retune models.
The following changes are OPTIONAL. - These changes can be done in Build138 before project upgrade or in Build139 after project upgrade.
  • Hydrocyclone Plitt method - there is a corrected calculation for sharpness term, it is recommended that you change to this. Please solve and retune models.
  • EHX Sub Model - if using the Loss to Ambient method, there is a replacement Loss to Ambient 4 method with corrections, is recommended that you change to this new method. Please solve and retune models.
  • Falling Film Evaporator model - This is a legacy model with limited functionality, it will be removed in the next version. Please change to the Falling Film Evaporator 4 unit, it has more features and can be included as part of the flash train.
  • Crush1 and Mill(1) models - These are legacy models with limited functionality, they will be removed in the next version. Please change to the Crusher2 unit.

TPS Project upgrade from Build138 to Build139

Users with existing projects using TPS add-on models (AQSol, ChemApp or PHREEQC) need to manually update the configuration file (eg: edit using Notepad++) to
  1. contain the TPS database location, please see Specifying databases for project load in SysCAD configuration file for more information.
  2. change between demo version and license version of the software, please see Settable Options in SysCAD configuration (.cfg) file

Upgrading projects to Build139

Once the projects have been updated to use the latest methods in Build138, they should auto-upgrade in Build139:
Build139 Project Upgrade - project will be auto upgraded to the Build139 format, user will be forced to complete "Project Save Version" or "Project Save As" to save to the new Build139 format. The follow files will be moved to new subfolders:
  • All Graphics pages will be moved to the new subfolder: DocsGraphics.
  • All Trend pages will be moved to the new subfolder: DocsTrend
  • Other.dat is renamed to Controls.Data and exclusively contains PGM & MP data.
  • Projects and cfgfiles auto upgrade to always use “IF97” steam equation,
    “IF97_2” is removed as an option for various dropdown lists (eg: Plant Model - Species Tab).
Project Update in Build139 after project upgrade: