FAQ - Project related questions

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ Frequently Asked Questions ➔ Project Questions

Getting Started and Installation SysCAD Licensing Training Tutorial Guidelines and Examples
Getting Started Installation
Instructions
Installation
Tests
SysCAD Files SysCAD Licensing License Options Crypkey Software Training Information Training Preparation Tutorial Overview Tutorial Videos Modelling
Guidelines
Example Projects Example Reports Example PGM Files FAQ Upgrading Projects

Latest SysCAD Version: 25 February 2021 - SysCAD 9.3 Build 138.28098

Frequently Asked Questions (FAQ) and Troubleshooting
General Questions Installation
Related
License
Related
Project
Related
Species
Related
Graphics
Related
Access/Trend
Related
Modelling
Related
Reactions
Related
Mass&Energy
Balance
Flashing /
Flash Train
PGM
Related
Dynamic
Related
Tips &
Tricks

Can Projects be upgraded easily to a new version?

Please see Upgrading Projects and Upgrading Builds for detailed project upgraded information.

Please also see SysCAD release notes for what is new/changed. Upgrade notes are documented in the release notes:

How are files stored in a SysCAD project?

  • SysCAD project folder has the extension .spf (syscad project folder). This extension should not be deleted.
  • The SysCAD project folder contain a number of documents, these may include:
    1. Model files - ModelData.db3, stores the project model data.
    2. Graphics files - xxxx.DXF and xxxx.scg file. These are always in pairs, the .scg file is used to load the .dxf into SysCAD. In Build139 and later, these are stored in sub folder \DocsGraphics.
    3. Trend files - xxxx.trn file. In Build139 and later, these are stored in sub folder \DocsTrend.
    4. Control files - stored in sub folder \Controls. This is optional, used to store .pgm and .mp files used by general controller and model procedure files.
    5. Reaction files - stored in sub folder \Reactions. This is optional, used to store .rct files
    6. Report Files - stored in sub folder \Reports. This is optional, used to store SysCAD reports.
    7. Backup files - Backup.CfgFiles.2.zip and Backup.RmtFiles.zip. Used to store a copy of the cfgfiles and any remote files used by the project.
    8. Historian files - Histxxxx.xxx. Used to store data when historian is switched on.
    9. Various Project ini files
    10. Project.spj file. This file must NOT be renamed, SysCAD requires this file to load the project.

Please see SysCAD Files and Project Structure for more information.

How do I create a new project?

In SysCAD whenever a new project is created you are first asked to select a configuration file. The configuration file is used for selecting species, options, data and settings that would be used by many projects.

The SysCAD Tutorial documentation has step-by-step instructions on this and there is also a short video is the Tutorial section at Basic Tutorial - Starting a New Project

How do I send a project to another user?

The user must zip and send the entire project folder, preferably with relative path names.

For example for a project folder called FullPlantModel.spf - zip up this folder (including sub-folders) as FullPlantModel.spf.zip.

The user may optionally include the following steps:

  1. Also zip and send the CfgFiles folder. However, the required files are also contained in the project folder, so this is not essential.
  2. If the zip file is large, you may delete any Hist_Dat.xxx files (historian data files) to reduce the size of the zip file, if required.

How do I open a project sent from another user?

The user must follow these steps:

  1. Unzip the file received from the other user following the relative path names or unzip to a new folder with the correct project name and extension. For the example above this would be FullPlantModel.spf.
  2. After the project is unzipped, open the project, SysCAD will detect that the configuration file folder is "missing" and will give you an option to extract it from the Backup.CfgFiles.2.zip.
    • This zip file contains the back up files that the project needs to run. For example, the species database, and the project configuration file, etc.

See Open Project - Configuration File is Missing for more information.

What is a configuration file?

A configuration (cfg) file is used for common configuration for use by multiple projects. The configuration file can only be edited when all the projects are closed, from the Edit menu, select Project Configuration.

In Summary, it includes the following:

  1. It allows the user to select Unit Operations to be used in the project. For example, if SysCAD is running in ProBal Mode only, all the Dynamic Models can be deselected to make the list shorter. One thing to note is that the unit operation models are normally limited by the license as well.
  2. It allows the user to set up information such as the normal temperature, pressure, atmospheric pressure, default species model and so on.
  3. It allows the user to select chemical compounds to be used in the project.
  4. It allows the user to set up custom calculations, commonly used for user defined properties, ratios (such as Fe2+/Fe3+) and so on.
  5. If required, it allows the sieve series and size distribution data to be defined. Only valid for users with the Size Distribution Module (add-on).

Please see Project Configuration for more information.

What are referenced files?

The referenced files are those written by the user, external to SysCAD. These include any Excel Reports, PGM files (including Model Procedure files), reactions files, script files and driver files.

The referenced files are normally stored within the project folder.

  • Reaction files, .rct, are stored in a folder within the project called Reactions.
  • Control files, .pgm and .mp, are stored in a folder within the project called Controls.

It is a good idea to also store other reference files within the project folder as this will help to keep the project self-contained. However, it is possible to store them under other designated folders, eg, the cfgfiles folder.

It is up to the user to keep to a consistent format for good project management.

Please see Location of Project Files for more information.

How do I create SysCAD reference files, are there any templates available?

The available template files are stored in SysCADXXX\Basefiles folder.

  • PGM and MP files - As the general model or model procedures files are created, SysCAD will provide an automatic template.
  • Rct files - Reactions files can be created using the Reaction Editor. For Text file format, a template can be found in the Basefiles folder.
  • Excel files
    1. See Report Types for keywords.
    2. See ..\SysCADXXX\Examples\01 Reports folder for distributed example reports to be used as templates.
    3. In Build 137 and later, users can now run standard Steady State SysCAD reports for their projects. These are off-the-shelf ready to go reports that will work for all steady state projects. Refer to New Report Template and Report Templates and Default Reports for more information.
  • Various example projects will contain excel report, reaction files, PGM files and so on, they can be used as templates for user projects. Please see Example Projects for more information.
  • The SysCAD tutorial has step-by-step instructions on how to create these reference files.

How do I change a project from ProBal to Dynamic or vice-versa?

For SysCAD 9.3 Build 137 and later:

Significant change has been made in SysCAD 9.3 Build 137 regarding Project Solver Mode Change. The Project Solve Mode is now set in the Project Configuration (cfg File). A user must have:

  • a Steady State Solve mode configuration file to load a steady state project and
  • a Dynamic Solve mode configuration file to load a Dynamic project

If a user has a steady state project and wishes to change to Dynamic, please do the following:

  1. Ensure that your license allows you to use the desired mode.
  2. Edit the configuration file, select the Dynamic Radio button in Step 1 and Step 2 of the Edit Configuration dialog. When finished, the configuration file will appear under the Dynamic List. (Alternatively, user can choose to copy the configuration file as Dynamic Mode, once the file is created, the user may still need to edit this new file to include dynamic model selection.)
  3. Open the project using Alternate Configuration, select the Dynamic configuration file you have just created to open the project.
  4. You will then get the following dialog box:
    SS to Dyn.png
    Choose "Change Project SolveMode to : Dynamic".
  5. The project should now open in Dynamic mode. Save the project.
  6. The project is now ready for Dynamic project configuration / changes.

Note: If you have separate steady-state and dynamic licenses, perform step 2 with the steady-state license and the remaining steps with the dynamic license.

For SysCAD 9.3 Build 136:

  1. Ensure that your license allows you to use the desired mode.
  2. Check the configuration file of the project to ensure that the desired mode is enabled. Although it is possible that both solver modes can be enabled in the one configuration file (see General Configuration), it is usual to have one cfg file for ProBal and another for Dynamic. NB your project must be closed for you to be able to edit the configuration file.
  3. Again with your project closed, choose Edit - Project Settings and change the Network Solution to the desired mode. You can now open your project in the new mode.

Project Solve Mode Mismatch

In SysCAD 9.3 Build 137 or later, when opening an existing project created in an earlier version of SysCAD, it is possible for the project solve mode and cfg file solve mode to be mismatched. To resolve this issue, please edit the configuration and change it to the correct solve mode, then reopen the project. Please see Open Project - Project Solve Mode Mismatch for more information.

My project will not converge, how can I find the problem unit(s)?

One way to troubleshoot projects that either will not converge, or are very slow to converge is as follows:

  • With the project solving, click on the ‘Errors’ button on the solver status dialog window.
  • This shows you the units in the project with the largest errors – with the biggest ones at the top and getting smaller down the list.
  • Right click on the top line (you can pause the simulation at this point, if you prefer) and you will see the following dialog:
    Find Error.png
  • You can then click on ‘Find X-001’ or ‘Access X-001’ (or whichever unit SysCAD says is causing the problem)
  • This will highlight the unit causing the problem and you can then determine why it is preventing convergence.

Once you have fixed the worst problem, the project may converge quickly, or you may need to repeat this with the next worst problem.

See also Solver

Pressure out of Project Range

The user will receive a message 'Pressure out of Project Range' if the specified or calculated pressure is above the maximum project pressure, or less than the minimum project pressure. These minimum and maximum project pressures are specified in the configuration file.

For example, if the message reads: 'Pressure out of Project Range (450 > 350)', the maximum pressure in the configuration file was specified as 350kPa. The resolution of this issue is to either:

  1. Change the required pressure so that it is within the project range, in this case less than 350kPa. However, if you do require the pressure to be above 350kPa then go to the following step
  2. Change the operating pressure range in the configuration file as follows:
    • Close the project
    • Go to Edit - Project Configuration and select or browse for the correct xxxx.cfg file that you are using.
    • Select the file and press the Edit button.
    • On step 2, click on the Configuration tab, change the maximum, and if required, the minimum pressure to reasonable values.
    • Press OK to close.
    • You can now load up the project again and the pressure warning messages will no longer be valid.

Why does it take a long time to open or save a project?

The time to open or save a project depends on the project size but should normally take between about 5 and 30 seconds.

  • If SysCAD seems to pause during a load or save and take longer than expected, it may be because it is looking for files in connections that do not exist on the current machine.
  • For example, if you are sharing a project with someone and they have file locations in the Reports that are not connected to your machine, SysCAD will try to make the connection until it times out.
    In the example below, the Excel file DataSet01.xls is on the local machine and the file DataSet03.xls is on a network machine. If the computer does not have the connection to that network location, it will slow down load and save.
    FAQLongTimeOpen.png
  • Just remove the missing connection (check Export Reports, Import Data and Trend Reports tabs) and it should speed things up.
  • You can always re-add the report locations if you need them later.

How do I divide a full plant model into smaller section models?

The instructions below assumes the user has access to the full plant model, and wants to keep only selected number of flowsheets to make it a smaller "section" model. To do so:

  1. Save a version of the project before you start so you don’t “corrupt” the main project.
  2. Run the project fully connected so that the results are populated.
  3. On the graphics page you wish to keep, use composition fetch to set up all the feeders, so that when you run the page by itself, the feeders will have flow. See Composition Fetch for more help.
  4. Then you can delete the unwanted graphics pages, if you want to delete multiple graphics, use “Graphics – Group Operations”, select all the graphic page you want to delete, then press the Delete/Close button.
  5. Save version – this will remove any unwanted dxf files in the project folder.

NOTE: if you only need one (or a few) flowsheet(s) out of the whole project, you can use Copy and Paste Graphics Commands to copy and paste the required flowsheet(s) into a new project.