Discontinued Unit Models

From SysCAD Documentation
Jump to navigation Jump to search

Navigation: User Guide ➔ SysCAD Version History ➔ Build 139 Release Notes ➔ Discontinued Unit Models

Build 139 Release Notes (Summary)
New Models and Add-Ons Model Improvements User Interface Improvements Other Improvements Changes that Affect Results Project Upgrade & Tag Changes Discontinued Unit Models

Latest SysCAD Version: 23 April 2024 - SysCAD 9.3 Build 139.35250

Related Links: Build 139 Revision History, Upgrading Projects, Discontinued Models and Dlls


The following Release Notes represent the state of Build 139 at the time of first release. Please refer to the Build 139 Revision History for subsequent updates.

Unit Model and Functionality - Discontinued

Models to be removed in next version

  • Crusher1 and Mill-1 - User will be given this note in the Access Window: === NOTE: This model will be discontinued - change to Crusher2 ===.
    • These are legacy models with limited functionality and will be removed in the next version. Please change to the Crusher2 unit, it contains more functionalities than the old models.
    • User should be able to reconfigure the model (using Crusher2) to provide equivalent behaviour.
  • Falling Film Evaporator - User will be given this note in the Access Window: === NOTE: This model will be discontinued - change to Falling Film Evaporator(4) ===.
    • This legacy model has limited functionality and will be removed in the next version. Please change to Falling Film Evaporator 4
  • EHX - Loss to Ambient Method - User will be given this note in the Access Window: ***** Method will be discontinued. Use 'Loss to Ambient4' instead! *****
    • This method contains conversion factor error for conductivity and will be removed in the next version.
    • EHX - Loss to Ambient 4 has been added with corrected conductivity values, please change any EHX sub models using "Loss to Ambient" method to this new method.

Models to be removed in future versions

Summary Table of Discontinued Models and Dlls

Discontinued Model Alternative Model Discontinued in Version Removed from Distribution in Version
The following models have been Discontinued.
Generic Bayer Species Model Alumina 3 Bayer Species Model 9.3 Build 136 9.3 Build 137
Precipitation Model Precipitation3
Screen Screen 2 9.3 Build 137 9.3 Build 139
Cyclone Hydrocyclone
Area None 9.3 Build 139 9.3 Build 139
The following models will be discontinued in the Next Major Build/Version updates.
Crusher1 Crusher2 Next Major Build Next Major Build
Mill-1 Crusher2
Falling Film Evaporator Falling Film Evaporator 4
OLI Chemistry Model OLI Model Configuration
OLI Sample Model OLI Direct Calc Model
OLI Reactor OLI Reactor 2
The following models will be discontinued in future Major Build/Version updates.
Direct Contact Heater Direct Contact Heater 2 Future versions
Heat Exchanger Shell and Tube Heat Exchanger 2 or Simple Heat Exchanger
Flash Tank Flash Tank 2
Falling Film Evaporator 2 Falling Film Evaporator 4
Shell and Tube Heat Exchanger Shell and Tube Heat Exchanger 2
Discontinued Dll Discontinued in Version Removed from Distribution in Version
Alumina.dll 9.3 Build 136 9.3 Build 137
ScdOLI.dll Next Major Build Next Major Build
Separ1.dll 9.3 Build 139 9.3 Build 139
Separ2.dll 9.3 Build 137 9.3 Build 139
XBasic.dll 9.3 Build 138 9.3 Build 138