  • to do the following: ; 1) Define the column number to use for test data ; 2) Sets the test data by executing SetTags (this is equivalent to pressing the
    19 KB (907 words) - 02:09, 21 February 2024
  • and [math]\displaystyle{ V_2 }[/math] Measured, Previous or Target Values in SysCAD SI Units [math]\displaystyle{ e_a = V_1-V_2 }[/math] Absolute error
    12 KB (2,123 words) - 10:57, 13 February 2024
  • For example, the user cannot configure the flash pressure required in the Flash Tank, as the Flash Train will calculate this. If the user has a Tie in a
    8 KB (1,137 words) - 09:43, 1 February 2024
  • if the user selects the 'Whiten Crusher' method. Selection/Breakage - The fields visible if the user selects the 'Selection/Breakage' method. Test Data -
    35 KB (768 words) - 04:54, 14 May 2024
  • General Options Colours (category User Interface)
    Navigation: User Guide ➔ Menu Commands ➔ Tools ➔ General Options ➔ Colours NOTE: The colour layers are in the order of importance, as shown in the following
    8 KB (97 words) - 23:44, 24 March 2024
  • \dfrac{1}{2dev} }[/math] (if Tavg - dev <= t <= Tavg + dev) Gaussian: [math]\displaystyle{ P(t) = \cfrac{1}{dev\sqrt{2\pi}}\cdot e^{\dfrac{-(t-Tavg)^2}{2dev^2}}
    25 KB (626 words) - 01:43, 6 September 2023
  • project is solved. Step 2: Insert unit operations Set Tag List and Get Tag List Step 3: Create 2 csv files, one containing the User Defined values for the
    19 KB (2,641 words) - 03:13, 7 February 2024
  • Navigation: User Guide ➔ COM Automation ➔ Python Automation ➔ Example - Unit Test Framework Unit Testing is important. Running a model to compare previous
    7 KB (993 words) - 18:34, 2 August 2023
  • the user to have a large amount of data available. Test data giving the crusher product size distribution for a given feed distribution. The user is required
    23 KB (1,654 words) - 09:30, 2 February 2024
  • the model would give the user a warning: SFW wash loss 7.5 is out of user specified range of data points (0 to 5) User without test data may set up a simple
    17 KB (1,773 words) - 04:11, 21 February 2024
  • Solve the project in its current build SysCAD 9.2. The last released Major build in SysCAD 9.2 is Build135, user should make sure the project is solved and
    9 KB (1,253 words) - 04:25, 16 November 2023
  • SysCADxxx\BasefilesUser\Conversions.db3 SysCADxxx\BasefilesUser\Symbols\*.* SysCADxxx\BasefilesUser\SysCAD.Machine.ini SysCADxxx\BasefilesUser\SysCAD.User.xxxx.ini
    13 KB (1,190 words) - 03:38, 5 April 2024
  • requires the user to have a large amount of data available. Test data giving the Mill product size distribution for a given feed distribution. The user is required
    23 KB (1,686 words) - 09:39, 2 February 2024
  • Therefore, please take care when using 'QProd', and if necessary test the values by displaying test values from different functions. As an example, when using
    20 KB (1,014 words) - 01:44, 6 September 2023
  • required to be able to insert these models into a project, it is required if the user wishes to use any of the PSD methods within the models. Some models require
    62 KB (2,065 words) - 03:33, 23 April 2024
  • may be useful if the user is in the feasibility study phase where the SysCAD flowsheet can remain untouched and many sets of test cases need to be performed
    11 KB (986 words) - 03:35, 5 April 2024
  • Build " & App.VersionNumber(2) & "." & App.VersionNumber(3) Application.StatusBar = "Started " & Version 'MsgBox Version '== Test Build number, and Exit if
    8 KB (1,059 words) - 17:42, 2 August 2023
  • then the user can access the Solver Setup (ProBal) dialog box to set the solve options. If one of the Dynamic modes is selected, then the user can access
    8 KB (1,102 words) - 05:10, 7 February 2024
  • value to 2 (Acid). Each item in the EnumDropList has an integer value. The names in the EnumDropList list need to be globally unique. If the user does not
    14 KB (1,480 words) - 06:26, 19 April 2024
  • er})^2} {\operatorname{MaxI} - \operatorname{MinI}} }[/math] Examples - GC_1.value1 = 100: GetSqr(GC_1.value1,0.2) ;returns 400. Thus (10*0.2)^2 GetSqr(GC_1
    33 KB (5,359 words) - 10:13, 1 February 2024
  • recommended. The user specifies how many tables of data are required (maximum is 500), the frequency of reporting (each table may be reported at a user specified
    15 KB (689 words) - 00:24, 17 April 2024
  • "_Y_", 3) ;r = "SysCAD" (nothing to replace) r = StrReplaceFrom(s, "s", "_Y_", 2) ;r = "Sy_Y_CAD" (case sensitive) w = StrLen(s) ;w = 6 r = StrUpr(s) ;r = "SYSCAD"
    19 KB (494 words) - 08:06, 13 May 2024
  • alert the user to this. Please refer to section Hints and Comments for more comprehensive hints on how to troubleshoots the controller, user can also have
    34 KB (2,509 words) - 03:27, 5 April 2024
  • either be the Feed or the Product Temperature (for methods 2 and 3), depending on which value the user has selected. Notes for "Loss to Ambient 4" The pipe may
    36 KB (1,127 words) - 03:33, 5 April 2024
  • opening any dynamic projects, user must first edit the configuration file to select the dynamic solve mode, alternatively, user can select to edit the configuration
    8 KB (1,304 words) - 05:00, 5 October 2023
  • Find Units using Query (category User Interface)
    Navigation: User Guide ➔ Edit ➔ Find Units using Query Related Links: Quick Find This feature allows user to search Any SysCAD variable using TagSelect
    13 KB (750 words) - 16:01, 2 August 2023
  • Navigation: User Guide ➔ COM Automation ➔ C++ Automation Below is a C++ source code that can be compiled to a console application. The example is similar
    6 KB (666 words) - 18:13, 2 August 2023
  • these occur as Halite (NaCl), Sylvite (KCl), Bischofite (MgCl2.6H2O), and Carnallite (KCl.MgCl2.6H2O). Exactly which species are produced in crystallisation
    13 KB (1,431 words) - 02:29, 3 October 2023
  • location. See also: How do I send a project to another user? How do I open a project sent from another user? Why can't I open the OLI project created by others
    11 KB (1,703 words) - 05:19, 28 March 2024
  • DotProduct = y.inner(y2) ;sum of each element y_i * y2_i, returns 45068 EndSub ;Logic d = a.GetLen() ;gets the array length a.SetAll(2.2/2) ;sets all elements
    20 KB (916 words) - 09:00, 10 May 2024
  • QFeed and QProd to Compressor, Valve 2, Pump 2, Piping System Model and Pressure Exchanger. Improved management of user selection of conversion units in the
    114 KB (16,094 words) - 02:05, 24 April 2024
  • distribution data can be defined as Overall Test Data (PRIMARY_MILL) or Individual Test Data (SECONDARY_MILL). The Crusher2 unit model is used to emulate the mill
    7 KB (1,026 words) - 10:45, 22 May 2023
  • quick test is to see if you can create (and then delete) a folder or file in the license folder, if you can't then you don't have the appropriate user permissions
    12 KB (1,768 words) - 09:54, 1 February 2024
  • ➔ Screen 2 The Screen 2 model allows the user to specify a single screening unit with a number of individual decks, up to a maximum of 8 decks. The user must
    20 KB (2,817 words) - 05:37, 14 May 2024
  • the General Separator is unimportant. The user may connect the streams to any position on the unit. If the user disables the unit, by un-ticking the On tick
    6 KB (942 words) - 09:26, 2 February 2024
  • type of tank (for example, CSTR). For this type of tank, the user may define additional user variables, then define some correlations (functions or subroutines)
    46 KB (4,504 words) - 01:29, 12 March 2024
  • we can then assign values: XIn = (c_double*3)() XIn[0] = 0.01 XIn[1] = 0.2 XIn[2] = 0.0 Finally we can actually call the function: rate = pd.rateFn(T, P
    11 KB (1,786 words) - 18:53, 1 September 2022
  • a dynamic matrix and manipulate its elements. The user may read in a matrix from a text file. The user may set constant values into a matrix when it is
    36 KB (1,044 words) - 12:28, 9 January 2024
  • may contain user defined individual phases. However, the phase description must match what has been defined in the species database. User must check the
    8 KB (79 words) - 23:14, 25 May 2021
  • }[/math] [math]\displaystyle{ U2 = U1^2 \left(1 + CV^2\right) }[/math] [math]\displaystyle{ U3 = U1^3 \left(1 + 3 CV^2\right) }[/math] The massecuite at
    29 KB (2,700 words) - 09:37, 2 February 2024
  • [math]\displaystyle{ C(x) = 1-\left(\cfrac{K_2-x}{K_2-K_1}\right)^{K_3}, \qquad K_1 \lt x \lt K_2 }[/math] Where the parameters K1, K2 and K3 can be entered directly
    14 KB (1,789 words) - 04:42, 14 May 2024
  • 3. SysCAD 9.2 Build 135 is the last release of SysCAD 9.2. Please see Revision History for SysCAD 9.2 for details on changes in SysCAD 9.2 versions. SysCAD
    33 KB (5,180 words) - 11:24, 14 February 2024
  • Navigation: User Guide ➔ Edit ➔ Project Configuration (cfg File) ➔ Calculation Configuration ➔ User Property Expressions NOTES: Function SumPhase() has
    15 KB (79 words) - 23:14, 25 May 2021
  • equivalent to Real a1*, b1* INTEGER a2{result}, b2{r} ; a2 and b2 are result fields - equivalent to INTEGER a2@, b2@ Real a3{c}, b3{r,c} ; a3 is a concealed
    24 KB (1,906 words) - 03:11, 2 May 2024
  • From within the Configuration Editor at Step 2 of 2, double click on a species or click on the Edit User Database button. In the 'Project Configuration'
    21 KB (3,316 words) - 04:42, 6 September 2023
  • [math]\displaystyle{ \operatorname{erf}(z) = \dfrac{2}{\sqrt{\Pi}} \,\int\limits_{0}^{z} \, e^{-t^2} \, dt }[/math] Recovery to underflow for a given solid
    943 bytes (400 words) - 09:58, 22 December 2021
  • Navigation: User Guide ➔ View ➔ Plant Model ➔ Settings This tab page on the Plant Model Access Window has a number of parameters that the user may either
    11 KB (32 words) - 17:10, 2 August 2023
  • from 9.1 to 9.2 see Upgrade to SysCAD 9.2. See SysCAD 9.2 Release Notes for a list of new features and changes from SysCAD 9.1 to SysCAD 9.2 Build 131. Allows
    13 KB (2,038 words) - 19:09, 2 August 2023
  • is running. The user specifies how many tables of data are required, the frequency of reporting (each table may be reported at a user specified time) and
    17 KB (1,542 words) - 19:04, 2 August 2023
  • stand-alone unit; or as part of a Flash Train. The user sets the operational mode of the Evaporator. However, if the user sets the mode as Flash Train and the Evaporator
    7 KB (1,469 words) - 03:58, 24 April 2024